Pen sensor/high-precision inductive probe Electronic probe: SYLVAC,P2,P5,P10,P25,P50
High precision inductance probe: SYLVAC,P2,P5,* The image shows the application of the sensor
*B=Roller bearing; V=vacuum lift; L=Right angle type; S=The measuring head is equipped with a rubber protective cover. Unless otherwise specified, it refers to friction bearings P10, P25, P50 with inductive probes or sensors
| Technical parameters: | |||||||
| model | measuring range | Pre itinerary | maximum error | Correction error | Repeatability | Standard force measurement | Waterproof standard |
| P2BL | 2mm | 0.25mm | 1.5µm | 0.5µm | 0.2µm | 0.60-0.75N | |
| P2B | |||||||
| P2BV | |||||||
| P2BVL | |||||||
| P5 | 5mm | 0.7mm | 1.6µm | 0.6µm | 0.2µm | 0.60-1.20N | IP64 |
| P5BL | 0.50-0.90N | ||||||
| P5V | 0.60-1.20N | ||||||
| P5B | 0.50-0.90N | ||||||
| P5BV | 0.50-0.90N | ||||||
| P5L | 0.60-1.20N | ||||||
| P5BVL | 0.50-0.90N | ||||||
| P5LV | 0.60-1.20N | ||||||
| P10 | 10 mm | 0.5 mm | 1.6 µm | 0.6µm | 0.2µm | 0.60-0.80N | IP40 |
| P10S | 0.70-1.25N | IP50 | |||||
| P10L | 0.60-0.80N | IP40 | |||||
| P10LS | 0.70-1.25N | IP50 | |||||
| P25 | 25 mm | 0.8 mm | 1.9µm | 0.8µm | 0.2µm | 0.60-1.00N | IP40 |
| P25S | 0.70-1.40N | IP50 | |||||
| P50 | 50 mm | 1 mm | 3.9µm | 1.5µm | 0.4µm | 0.50-1.10N | IP40 |
| Technical parameters: | |||||||
| model | measuring range | Pre itinerary | maximum error | Correction error | Repeatability | Standard force measurement | Waterproof standard |
| P2BL | 2mm | 0.25mm | 1.5µm | 0.5µm | 0.2µm | 0.60-0.75N | |
| P2B | |||||||
| P2BV | |||||||
| P2BVL | |||||||
| P5 | 5mm | 0.7mm | 1.6µm | 0.6µm | 0.2µm | 0.60-1.20N | IP64 |
| P5BL | 0.50-0.90N | ||||||
| P5V | 0.60-1.20N | ||||||
| P5B | 0.50-0.90N | ||||||
| P5BV | 0.50-0.90N | ||||||
| P5L | 0.60-1.20N | ||||||
| P5BVL | 0.50-0.90N | ||||||
| P5LV | 0.60-1.20N | ||||||
| P10 | 10 mm | 0.5 mm | 1.6 µm | 0.6µm | 0.2µm | 0.60-0.80N | IP40 |
| P10S | 0.70-1.25N | IP50 | |||||
| P10L | 0.60-0.80N | IP40 | |||||
| P10LS | 0.70-1.25N | IP50 | |||||
| P25 | 25 mm | 0.8 mm | 1.9µm | 0.8µm | 0.2µm | 0.60-1.00N | IP40 |
| P25S | 0.70-1.40N | IP50 | |||||
| P50 | 50 mm | 1 mm | 3.9µm | 1.5µm | 0.4µm | 0.50-1.10N | IP40 |
| Technical parameters: | |||||||
| model | measuring range | Pre itinerary | maximum error | Correction error | Repeatability | Standard force measurement | Waterproof standard |
| P2BL | 2mm | 0.25mm | 1.5µm | 0.5µm | 0.2µm | 0.60-0.75N | |
| P2B | |||||||
| P2BV | |||||||
| P2BVL | |||||||
| P5 | 5mm | 0.7mm | 1.6µm | 0.6µm | 0.2µm | 0.60-1.20N | IP64 |
| P5BL | 0.50-0.90N | ||||||
| P5V | 0.60-1.20N | ||||||
| P5B | 0.50-0.90N | ||||||
| P5BV | 0.50-0.90N | ||||||
| P5L | 0.60-1.20N | ||||||
| P5BVL | 0.50-0.90N | ||||||
| P5LV | 0.60-1.20N | ||||||
| P10 | 10 mm | 0.5 mm | 1.6 µm | 0.6µm | 0.2µm | 0.60-0.80N | IP40 |
| P10S | 0.70-1.25N | IP50 | |||||
| P10L | 0.60-0.80N | IP40 | |||||
| P10LS | 0.70-1.25N | IP50 | |||||
| P25 | 25 mm | 0.8 mm | 1.9µm | 0.8µm | 0.2µm | 0.60-1.00N | IP40 |
| P25S | 0.70-1.40N | IP50 | |||||
| P50 | 50 mm | 1 mm | 3.9µm | 1.5µm | 0.4µm | 0.50-1.10N | IP40 |