Xiamen Jilongde Environmental Engineering Co., Ltd
Home>Products>In situ nutrient analyzer
Product Groups
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    13806020340
  • Address
    Room 704, Building 3, Xinglinwan Operations Center, Jimei District, Xiamen City
Contact Now
In situ nutrient analyzer
In situ nutrient analyzer
Product details

KLD-C Probe in-situ nutrient water quality analyzer is an online float type multi parameter water quality analyzer used to measure nutrients in surface water and seawater. It can measure ammonia nitrogen (NH3-N), phosphate (PO4-P), total phosphorus (TP), nitrate nitrogen (NO3-N), nitrite nitrogen (NO2-N), total nitrogen (TN), permanganate index (CODMn), CODUV and other parameters. One instrument can automatically measure up to four parameters. It is fixed by installing a small self powered buoy; Record and save measurement data directly through the host; Realize data query and management through a portable control box.
The design of KLD-C Probe in-situ nutrient water quality analyzer is highly suitable for the integration of buoys. The immersion design can be easily placed in the reserved hole of the buoy marker and easily fixed with chains and hooks.
The reagent bag is externally placed inside the top compartment, without disassembly, and can be directly filled with reagents. It is easy to clean, reduces cross contamination between reagents, and facilitates reagent replacement.
Wireless terminals or Bluetooth can be used for operation, and the host can still perform terminal operations while uploading data, making it convenient for on-site maintenance. (Not standard)

yyy.jpg

Features and advantages:

  • Unique light source colorimeter and fluorescence meter for detection.

  • A unique reflux reactor with low consumption of reagents and calibration solution, minimal maintenance, and an expected replacement cycle for reagents45Oh my god.

  • The medicine is built-in inside the analyzer and does not need to be disassembled. It can be directly filled with medicine, and the operation is simple.

  • It has a drug shortage alarm function, and the alarm amount can be set by oneself.

  • There is a leakage alarm function inside both the medicine warehouse and the analyzer.

  • Serial communication interface, throughRS232/MODBUSPerform data transmission.

  • Instruments can be remotely controlled and operated through software.

  • The seawater specific communication cable with titanium alloy joints can achieve underwater plugging and unplugging, and the electrical joints are made of gold-plated material, reducing energy consumption.

  • Additional medication compartments can be configured to facilitate medication replacement.

  • Maximum water resistance100mPressure, suitable for in-situ analysis.

  • The device can be wirelessly connected to a computer (optional), and the instrument can be operated wirelessly through software for easy on-site maintenance.

  • Low power consumption, low voltage12VDC power supply, no need for inverter conversion to220VThe electrical connection point adopts gold-plated joints to reduce impedance.

  • The platform can display the remaining amount of medication on the device, making it convenient for customers to maintain it in a timely manner.

Application scope:

  • Accumulated basic data of nearshore waters

  • Monitoring and early warning of water quality in nearshore aquaculture areas

  • Surface water monitoring

  • Red tide warning

Analysis principle:

Using advanced waterway analysis technology, the sample and chemical reagents are pumped into the flow path chamber for reaction through a high-precision micro peristaltic pump. After the reaction is complete, optical testing is automatically performed to obtain in-situ data of the sample.

Technical parameters:

measurement type

User manual or set interval automatic analysis

Measurement Interval

It can be freely programmed according to the actual situation, or it can beRS232recriminate

compare colour count

Light source colorimeter andFluorometer

inspect measure limit

≤2%

weight repeated sexually

≤5%

zero drift

≤5%F. S

Span Drift

≤10%F. S

signal output

standardRS232/MODBUSDigital Output

Sample and waste liquid transportation

No pressure required

Storage temperature of pharmaceuticals

10-30℃

Medication replacement cycle

Not less than30The weather depends on the ambient temperature

ambient temperature

5-40℃

Waterproof grade

IP68

mean time between failures

>720h/order

Automatic running time

1.5Months, depending on the measurement interval

electricity source

12VDC, designed to be powered by solar energy (also available through)AC 220VPower supply)

weight measure

make an appointment10kg

chi cun

(diameterxheight)

Φ140 x650mm

250 x700mm

250 x700mm

250 x700mm

250 x700mm

250 x700mm

testing index

parameter

Technical performance

CODuv

Method principle

Optical UVUVlaw

measure Cheng

2~50mg/L(Range can be ordered according to requirements)

Time

8min

inspect measure limit

2%F.S

weight repeated sexually

≤±5%

zero drift

≤±5%F.S

Span Drift

≤±5%F.S

testing index

parameter

Technical performance

TP

Method principle

High Temperature Oxidation+UVDissolve, molybdate ascorbic acid colorimetric method

measure Cheng

0.1~1mg/L(Range can be ordered according to requirements)

Time

35min

inspect measure limit

2%F.S

weight repeated sexually

≤±2%

zero drift

≤±5%F.S

Span Drift

≤±5%F.S

testing index

parameter

Technical performance

TN

Method principle

UVDissolve,DTPARestoration,1-Naphthalene ethylenediamine dihydrochloride+Colorimetric method for p-aminobenzenesulfonamide

measure Cheng

0.1~1mg/L(Range can be ordered according to requirements)mg/L

Time

35min(Freshwater)/45min(Sea water)

inspect measure limit

1%F.S

weight repeated sexually

≤±5%

zero drift

≤±3%F.S

Span Drift

≤±5%F.S

testing index

parameter

Technical performance

PO4-P

Method principle

Molybdate ascorbic acid colorimetric method

measure Cheng

0.1~0.5mg/L(Range can be ordered according to requirements)

Time

10min

inspect measure limit

2%F.S

weight repeated sexually

≤±2%

zero drift

≤±4%F.S

Span Drift

≤±2%F.S

testing index

parameter

Technical performance

NH3-N

Method principle

Phenol colorimetric method

measure Cheng

0.1~1mg/L(Range can be ordered according to requirements)

Time

15min(Freshwater)/20min(Sea water)

inspect measure limit

2%F.S

weight repeated sexually

≤±5%

zero drift

≤±5%F.S

Span Drift

≤±10%F.S

testing index

parameter

Technical performance

NO2-N

Method principle

1-Naphthalene ethylenediamine dihydrochloride/Colorimetric method for p-aminobenzenesulfonamide

measure Cheng

0.1~0.5mg/L(Range can be ordered according to requirements)

Time

10min

inspect measure limit

2%F.S

weight repeated sexually

≤±3%

zero drift

≤±5%F.S

Span Drift

≤±5%F.S

testing index

parameter

Technical performance

NO3-N

Method principle

NED1-Naphthalene ethylenediamine dihydrochloride)+SAA(Aminobenzenesulfonamide) colorimetric method

measure Cheng

0.1~1mg/L(Range can be ordered according to requirements)

Time

15min(Freshwater)/30min(Sea water)

inspect measure limit

2%F.S

weight repeated sexually

≤±5%

zero drift

≤±5%F.S

Span Drift

≤±10%F.S

testing index

parameter

Technical performance

sulfide

Method principle

N,N-Dimethyl p-phenylenediamine+Ferric chloride colorimetric method

measure Cheng

0.2~2mg/L(Range can be ordered according to requirements)

Time

10min

inspect measure limit

2%F.S

weight repeated sexually

≤±3%

zero drift

≤±5%F.S

Span Drift

≤±2%F.S

testing index

parameter

Technical performance

silicate

Method principle

Silicon molybdenum blue colorimetric method

measure Cheng

0.2~2mg/L(Range can be ordered according to requirements)

Time

15min

inspect measure limit

2%F.S

weight repeated sexually

≤±3%

zero drift

≤±3%F.S

Span Drift

≤±2%F.S

    label:
    Online inquiry
    • Contacts
    • Company
    • Telephone
    • Email
    • WeChat
    • Verification Code
    • Message Content

    Successful operation!