Controlled by an ARM-32 bit microprocessor, it is reliable, stable, and highly intelligent |
![]() |
Fast dynamic response and stable speed |
![]() |
Three phase vector control, automatic balancing of three-phase voltage |
![]() |
High voltage stabilization accuracy |
![]() |
High frequency stability |
![]() |
Adopting a 7-inch touch screen display and control, the interface is beautiful and the parameter display is diverse |
![]() |
Isolation of power frequency transformer, pure sine wave output of power frequency inverter power supply |
![]() |
RS232 communication interface, standard MODBUS-RTU protocol, can be converted to CAN, TCP/IP interfaces, remotely viewed and controlled through a mobile app |
input parameters
| parameter name | indicator | Remarks |
| DC36V-72V | Optional voltage, can accept non-standard customization |
bus | Multiple circuit options | customizable |
input switch | DC MCB switch/AC MCB switch |
|
output parameters
| parameter name | indicator | Remarks |
modulation scheme | IGBT/SPWM sine wave pulse width modulation method |
|
output voltage | Three phase 380V/400V/, single-phase 220V/230V | Customizable voltage output |
Output voltage stability (average value) | ±1%(可定制更高精度) |
|
reaction time | 2mS (for input voltage) |
|
stabilization time | <20MS recovery to within 5% |
|
Voltage waveform distortion THD | <3% (linear load)<5% (non-linear load) |
|
output frequency | 50HZ/60HZ |
|
Frequency stability | < 0.1% |
|
phase shift | When the load is balanced in three phases or when there is no load, it should be ≤ ± 1 °; 100% three-phase imbalance: ≤± 4 ° |
|
Three-phase unbalance degree | Three phase voltage automatic balancing |
|
Isolation transformer | △/Y or Y/Y |
|
Bypass function | IPA11/IPA31/IPA33 series optional automatic bypass function, with an inverter to bypass switching time of<4MS |
control parameters
| parameter name | indicator | Remarks |
Main control components | The main measurement and control chip adopts ARM32-bit processor, and the inverter component adopts IGBT |
|
carrier frequency | 4K;8K; 12K; 16K optional |
|
Control voltage and current acquisition method | valid value |
|
Control method | Voltage closed-loop control, current closed-loop control, or VF curve control |
|
interface | RS485, MODBUS-RTU protocol | Optional RS232, CAN, TCP/IP, GPRS |
Display parameters
| parameter name | indicator | Remarks |
Display medium | 7-inch touch screen or 192 * 64 (LCD) |
|
|
| Input voltage and current; |
|
Display alarm content | Fuse breakage, high IGBT temperature, high transformer temperature, IGBT failure, overload, input undervoltage, etc |
|
Rated parameter display accuracy | Level 1.0 |
|
Voltage parameter resolution | 0.1V | Customizable higher resolution |
Resolution of current parameters | 0.1A | Customizable higher resolution |
protection parameters
| parameter name | indicator | Remarks |
| Input no fuse switch, output no fuse switch, electronic circuit quickly detects overcurrent, overvoltage, overload, high temperature, IGBT alarm, fuse alarm, short circuit and automatic tripping protection and alarm |
|
protection method | Cut off output |
|
physical parameters
| parameter name | indicator | Remarks |
cooling method | Natural cooling or forced air cooling |
|
Protection level | Indoor IP20; Outdoor IP23 or higher rating |
|
Model Naming
![]() |
![]() |
Three phase model specifications
| Model number | Capacity (kVA) | Output current (A) | Overall dimensions |
IPD03-003/IPA13-003/IPA33-003 | 3 | 4.6 | 350×650×670 |
IPD03-006/IPA13-006/IPA33-006 | 6 | 9.1 | |
IPD03-010/IPA13-010/IPA33-010 | 10 | 15.2 | |
|
IPD03-015/IPA13-015/IPA33-015 | 15 | 22.8 | 460×700×1170 |
|
IPD03-020/IPA13-020/IPA33-020 | 20 | 30.4 | |
|
IPD03-030/IPA13-030/IPA33-030 | 30 | 45.6 | |
|
IPD03-045/IPA33-045 | 45 | 68.4 | 780×650×1450 |
|
IPD03-060/IPA33-060 | 60 | 91.2 | |
|
IPD03-075/IPA33-075 | 75 | 114.0 | 950×700×1600 |
|
IPD03-090/IPA33-090 | 90 | 136.7 | |
|
IPD03-120/IPA33-120 | 120 | 182.3 | |
|
IPD03-150/IPA33-150 | 150 | 227.9 | 1200×750×1800 |
|
IPD03-200/IPA33-200 | 200 | 303.9 | |
|
IPD03-250/IPA33-250 | 250 | 379.8 | 1400×800×2000 |
|
IPD03-300/IPA33-300 | 300 | 455.8 | |
|
IPD03-350/IPA33-350 | 350 | 531.8 | 1500×1050×2200 |
|
IPD03-400/IPA33-400 | 400 | 607.8 | |
|
IPD03-500/IPA33-500 | 500 | 759.7 | 2400×1200×2200 |
|
IPD03-600/IPA33-600 | 600 | 911.6 | |
|
IPD03-800/IPA33-800 | 800 | 1215.5 | 1500 × 1050 × 2200 two cabinets |
|
IPD03-1000/IPA33-1000 | 1000 | 1519.4 | 1500 × 1050 × 2200 three cabinets |
|
IPD03-1200/IPA33-1200 | 1200 | 1823.3 |
Note:Customizable external dimensions and protection level.
Single phase model specifications
| Model number | Capacity (kVA) | Output current (A) | Overall dimensions |
|
IPD01--500W/IPA11-500W | 0.5 | 2.3 | 425×436×173 |
|
IPD01-001/IPA11-001 | 1 | 4.5 | |
|
IPD01-002/IPA11-002 | 2 | 9.1 | 350×650×670 |
|
IPD01-003/IPA11-003 | 3 | 13.6 | |
|
IPD01-005/IPA11-005 | 5 | 22.7 | |
|
IPD01-010//IPA11-010 | 10 | 45.5 | |
|
IPD01-015/IPA31-015 | 15 | 68.2 | 460×700×1170 |
|
IPD01-020/IPA31-020 | 20 | 90.9 | |
|
IPD01-030/IPA31-030 | 30 | 136.4 | |
|
IPD01-045/IPA31-045 | 45 | 204.5 | 780×650×1450 |
|
IPD01-060/IPA31-060 | 60 | 272.7 | |
Note:Customizable external dimensions and protection level.