The INT05-N single-chip Michelson interferometer is provided to companies that wish to establish proprietary near-infrared Fourier transform spectrosc
Product details

INT05-N Single Chip Integrated Michelson Interferometer - Michelson Interferometer Product Description:

INT05-N single-chip integrated Michelson interferometer - Michelson interferometer is provided to companies that wish to establish proprietary near-infrared Fourier transform spectroscopy analysis. This device is the main optical component of a near-infrared spectrometer, with an aperture of 12.7mm and a working range of 2940-7700cm-1It is permanently aligned and fused with two arm mirrors, which image each other through a beam splitter compensator in a single component. The use of PLX's single-chip optical structure technologyTM(M.O.s.T.TM). The INT05-N interferometer has a very robust structure and never requires any adjustments. Add a moving retroreflector on one arm to complete the interferometer and allow for variations in optical path difference near zero OPD. Its sturdy structure and permanent alignment make the INT05 series near-infrared interferometer highly suitable for the most demanding near-infrared analyzer applications. PLX company can also customize INT05-N single-chip Michelson interferometers according to specific customer requirements to meet various application needs.

INT05-N单片集成迈克尔逊干涉仪-迈克尔逊干涉仪

INT05-N Single Chip Integrated Michelson Interferometer - Michelson Interferometer Product Features:

  • The main optical components of a near-infrared spectrometer, with an aperture of 7mm
  • Work range 2940-7700 cm-1
  • Non hygroscopic material
  • Single piece, sturdy structure, permanent alignment, no need for any adjustment
  • OPD controlled by LPR-05 low profile reflex mirror
  • Customizable according to user needs

Application scope:

  • Application of Near Infrared Analyzer

Technical parameters:

  • Aperture: Ø 0.50in/12.7mm
  • Outgoing wavefront: 0.10 WAVES P-V @ 633nm
  • Scope of work: 2940-7700 cm-1
  • Quality: 210 grams
  • Operating temperature: 20 ° -40 ° C
  • Operating temperature gradient: 2 ° C Absorbete< 2°C / 100mm