Anhui Weinuo Automation Instrument Co., Ltd
Home>Products>High temperature resistant installation line
Product Groups
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    18155076996
  • Address
    Development Building of Supply and Marketing Cooperative on Chezhan North Road, Tongcheng Town, Tianchang City
Contact Now
High temperature resistant installation line
High temperature resistant installation line
Product details

Product Details:

High temperature resistant fluoroplastic installation wire and cable

This product is suitable for connecting power supply equipment or instrument equipment in high temperature conditions, low temperature conditions, or special environmental conditions (such as acid, alkali, oil, or chemical reagents, etc.), as well as cables required for the above conditions.

1、 Model and Name
Perfluoroethylene propylene insulated installation wire (referred to as F46 installation wire).
AF46- Polyfluoroethylene propylene insulated installation line.
AF46span - Polyfluoroethylene propylene insulated shielded installation wire.
AF46F46span perfluoroethylene propylene insulated shielding sheath installation wire (cable).
Soluble polytetrafluoroethylene insulated installation wire.
AF4 PTFE insulated installation wire.
AF4span PTFE insulated shielding installation wire.

2、 Usage characteristics
The working voltage of the wire is AC rated voltage of 500V and DC voltage of 1000V.
According to the different core materials of the compensating wire, its long-term use temperature should not exceed: tin plated copper conductor: 150 ℃, silver plated copper conductor: 200 ℃, nickel plated copper conductor: 260 ℃, insulation resistance: (20 ℃) not less than 105m Ω. m.

3、 Product Structure Diagram
Delivery length
The length of the cable and wire coil is 100m, and short segments less than 2m are allowed to be delivered, with a quantity not exceeding 10% of the delivery quantity. Please specify the internal insulation when placing an order Color requirements.
Specifications, dimensions, and parameter data (representing specifications)

The nominal load area of the wire core is mm2

Core structure

Maximum outer diameter (mm)

Calculate weight Kg/Km

The DC resistance at 20 ℃ shall not exceed Ω/Km

Maximum number of surface cable cores

Number/diameter mm

outside diameter

mm

AF46

AF46P

AF46

F46P

AF4

AF4P

AF46

AF46P

AF4AF4P

AF46P

1

0.20

7/0.2

0.6

1.35

1.85

2.6

1.4

1.95

4.23

8.65

4.91

10.21

90

24

2

0.35

19/0.15

0.75

1.6

2.1

2.9

1.6

2.2

6.57

12.57

6.79

12.09

58

24

3

0.50

19/0.18

0.9

1.75

2.25

3.1

1.8

2.4

8.05

14.21

9.2

16.68

41.3

20

4

0.75

19/0.23

0.15

2.0

2.6

3.5

2.0

2.6

11.7

20.7

13.48

21.54

24.6

16

5

1.00

19/0.26

1.30

2.2

2.75

3.6

2.3

2.9

14.3

23.21

16.22

25.96

19.3

16

6

1.50

19/0.32

1.60

2.6

3.3

4.1

2.7

3.3

21.5

32.5

23.33

33.53

12.7

12

7

2.00

19/0.37

1.85

2.9

3.6

4.4

3.0

3.6

27.8

39.15

29.93

40.43

10.2

8

8

2.50

49/0.26

2.34

3.5

4.1

4.9

3.5

4.2

36.34

50.02

38.3

50.70

7.4

8

9

3.00

49/0.28

2.52

3.7

4.3

5.3

3.8

4.5

41.54

55.5

44.6

57.27

6.45

4

10

4.00

49/0.32

2.88

4.2

4.9

5.9

4.2

4.9

57.2

75.2

57.2

75.2

5.0

4

11

5.00

49/0.36

3.24

4.6

5.3

6.3

4.6

5.3

69.3

92.9

69.3

92.9

4.1

2

12

6.00

49/0.39

3.51

4.6

5.9

6.6

4.9

5.6

80.15

104.1

80.15

104.1

3.3

2


Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!