High temperature direct insertion zirconia oxygen analysis system
High temperature direct insertion zirconia oxygen analysis system
Product details

Application areas:Suitable for detecting oxygen content in high-temperature atmospheres in industrial heating devices such as metallurgy, electricity, heat treatment, ceramics, and cement.

Application furnace type:Industrial heating furnaces, refractory plant tunnel kilns, heat treatment furnaces, high-temperature atmosphere sintering furnaces, cement rotary kilns, garbage incinerators, etc.

characteristic:① Direct insertion structure, the detection element is installed at the top of the probe and inserted directly into the furnace. The probe has a fast response speed and directly converts the oxygen content into an electrical signal output.

② High temperature detection, the probe is composed of high-temperature resistant Australian imported sensors, corundum ceramic protective tubes, and PT platinum wires, with high accuracy and long service life.

③ Patent technology ceramic probe protector, corrosion-resistant and high-temperature resistant, capable of withstanding temperatures up to 1700 ℃.

① Oxygen probe measures ambient temperature: 600-1000 ℃ (oxygen probe uses 310S protective tube);

1000-1700 ℃ (ceramic protective tube is used for oxygen probe);

② Transmitter alarm output: 4-20mA isolated transmission output;

③ Transmitter alarm output: One channel alarm output;

④ Transmitter communication: RS485 isolated communication (optional)

⑤ System range: 0.01-20.9 O2%/1-209000ppm;

⑥ System response time: < 1 second when the measured atmosphere changes at the probe measurement end;

When inputting standard gas into the probe calibration hole: reach 95% response value within 5 seconds;

⑦ System installation environment: Oxygen probe Environmental temperature:- 20~120℃;

Installation environment temperature for transmitter and oxygen probe maintenance instrument: -10~50 ℃; Humidity<90%;

⑧ Structure: The oxygen probe adopts waterproof design and can be installed outdoors; The transmitter and maintenance device are both wall mounted and designed to be waterproof, and can be installed outdoors;

⑨ Effective length of oxygen probe: 600mm, 800mm, specially customized length;

⑩ Explosion proof grade: ExdII CT 6 (customized)


Customizable high-temperature direct insertion zirconia oxygen analysis system!