High precision rubber tensile testing machine
The DLB series rubber tensile testing machine is suitable for measuring the tensile force value of materials, as well as the bending and compression f
Product details
I. Overview
The rubber tensile testing machine is suitable for measuring the tensile force value of materials, as well as the bending and compression force values of materials.
two、Problems encountered during the experimental process:
1. After the computer software is connected online, a prompt box message appears indicating overload.
The solution is to check if the communication cable between the computer and the rubber tensile testing machine has come loose; Check if the online sensor selection is correct, and verify if the sensor has been hit during recent experiments or keyboard operations; Check if the software calibration or calibration function was used before the problem occurred; Check if calibration values, calibration values, or other information in hardware parameters have been manually changed.
2. The main power supply of the rubber tensile testing machine is not on and cannot move up and down.
The solution is to check if the power line connected to the rubber tensile testing machine is properly connected; Check if the emergency stop switch is turned on and if the power supply voltage connected to the testing machine is normal; Check if the fuse on the socket of the inspection machine is burnt out. Please remove the spare fuse and install it.
3. The main power supply of the rubber tensile testing machine is powered, but the equipment cannot move up and down.
The solution is to check if the device has not moved after 15 seconds (time), as the host needs to perform a self-test when turned on, which takes approximately 15 seconds; Check if the upper and lower limits are in the appropriate positions and have a certain operating space; Check if the power supply voltage connected to the testing machine is normal.
3、 Main technical specifications
|
Model number
|
DLB-100
|
DLB-200
|
DLB-300
|
DLB-500
|
|
heavy load
|
100N
|
200N
|
300N
|
500N
|
|
Scope of application
|
Various materials
|
|||
2.1 System accuracy:<0.5%
2.2 Resolution accuracy: 1N-5N
2.3 Stretching speed range: 10-150mm/min (special requirements to be determined separately)
2.4 Large stroke of activity gripper: 700mm
2.5 Power Supply Voltage: AC380V ± 10% 50Hz
2.6 Dimensions: 1000 × 700 × 2000 (mm)
2.7 Weight: 900kg
Online inquiry