SWY2288V/W high-frequency power meter
SWY2288V/W high-frequency power meter (RF millivolt meter/low-power meter) is an intelligent digital RF millivolt meter/low-power meter that can measure the effective value and corresponding power value of sine voltage with frequencies ranging from 200Hz to 1500MHz. The SWY2288V/W high-frequency power meter (RF millivolt meter/low-power meter) adopts the principle of detection and amplification, and has the characteristics of wide frequency response, small standing wave coefficient, high sensitivity, and high measurement accuracy. Due to its CPU controlled digital instrument, the SWY2288V/W high-frequency power meter (RF millivolt meter/low-power meter) achieves automatic range control and remote control function, and is an essential instrument for testing and measuring ultra-high frequency voltage and power in laboratory and workshop production.
characteristic:
Digital intelligent broadband RF voltmeter/low-power meter
High 11000 digital voltage value, four digit digital power value, and dBm
SWY2288V/W high-frequency power meter (RF millivolt meter/low-power meter) LCD screen displays multiple sets of parameters and dynamic changes simultaneously
Specially designed small voltage measurement calibration: ensuring measurement accuracy of<10mv
Configure coaxial probes to ensure excellent amplitude frequency characteristics from<10mv to 5v (See attached low-level frequency amplitude characteristic curve)
SWY2288V/W high-frequency power meter (RF millivolt meter/low-power meter) can automatically switch between 50 Ω and 70 Ω matching
Main technical performance:
1. Voltage measurement range:
1mv~10v, divided into four levels: 10mv, 100mv, 1v, and 10v* High display of 11000 words Choosing a 40dB voltage divider (optional) can achieve up to 300V
2. Measurement power range:
0.1μw~2000mw. Divided into four levels: 2 μ w, 200 μ w, 20mw, and 2000MW, with a high display of 2000 words
3. Measurement level range:
-47dbm~+33dbm(50ω),-48dbm~+31dbm(75ω).
4. Frequency range of measured voltage:
200Hz~1500MHz
5. Inherent error in voltage measurement:
± 1% ± 10 words, 10mv level ± 2% ± 30 words
6. Inherent error in power measurement:
± 3% ± 10 words, 2 μ w range ± 5% ± 30 words
7. Frequency response error:
200Hz~300MHz ≤±5%
300MHz~600MHz ≤±8%
600MHz~1000MHz ≤±12%
1000MHz~1500MHz ≤±18%
8. Power supply:
ac220v±10%,50hz±5%
9 Working temperature:
0℃~40℃
10. Size/Weight:
280×240×88(l×w×h)mm,3kg

Related products:YS-2499A(B)Series dual channel pulse waveform displayPeak microwave power meter (dual channel pulse high-power meter);GX2BB01Series microwave power meter (RF power meter); YS1125 (B) microwave signal source (RF signal generator);