Shenzhen Kerei Technology Development Co., Ltd
Home>Products>High frequency AC electric field calibration system HE18
Product Groups
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    15820799182
  • Address
    A-402, No. 44-1 Xintang Road, Xintian Community, Fuhai Street, Bao'an District, Shenzhen City
Contact Now
High frequency AC electric field calibration system HE18
Summary: The maximum frequency range is 18GHz, the maximum input power is 100W, the electric field strength range is 0.01~100V/m (depending on the inp
Product details



High-frequency alternating current
Field inspection system HE18

brief introduction

Kore Technology GmbH in Germanyhigh frequencyexchangeElectric field verification systemHE18canGenerate up to18GHzThe electric field, usersapproveRegarding electricitya place where people gatherstrengthTesterPerform continuous verification.

high frequencyAC electric field calibration systemHE18Mainly composed ofverificationPCEndsignalgeneratorPower amplifier, field strength monitoringInstrumentSoftware andGTEMSmall chamber composition.

application

high frequencyexchangeElectric field verification systemHE18Mainly used in metrology institutes, testing institutions, scientific research, laboratories,EMC Research and use units related to electromagnetic compatibility.

Characteristics

Øachievable100kHz~18GHzofEMCtest

ØConduct emission and immunity testing in a fixed shielding environment

ØsatisfyIEC/EN 61000-4-20andFCC ANSI C63.4The requirements

ØIt is achievedIEC/EN61000-4-3The most economical method of testing

ØThe generated field strength is uniformGood sex

ØAcross the entire frequency rangeVSWRgood

Main performance indicators

Frequency range

3G/6G/18GHzoptional

Input impedance

50Ω±5Ω(Typical values:50Ω±2Ω)

vswr

≤1.75(Typical values:≤1.5)

Input maximum power

100W

Range of electric field strength

0.01~100V/m(According to the input power level)

coaxial junction

L16(Ntype)

Maximum external dimensions

make an appointment6m×3m×2m(6riceGTEMcell) 4m×2.5m×2m(4riceGTEMcell)


major equipment



GTEMSmall room:GHzThe electromagnetic wave chamber receives the output signal of the amplifier and forms the required electric field, and the magnitude of the field strength can be measured by the field strength probe.

GTEMSmall room model

GTEM 4

GTEM 6

Longitudinal vertical length(m)

4

6

weight(kg)

200

400

Test net space(wide×tall)(mm)

400×200

600×300

signalGenerator:haveGPIBinterfaceCan be operated offline or online. When online, it can be controlled by a computer to perform corresponding operationsThe frequency can reach18GHz.

Power amplifier:Amplify the power of the small signal from the signal source, andsend outSend toGTEMThe required field strength is formed inside the small room.

standardField strength probe:measureGTEMThe electric field strength inside the small room is measured through dedicated cablesDisplay the standard field strength value on the field strength monitoring device.

Field strength monitoringinstrumentProcess the signal from the field strength probe and display it on the screenGTEMsmallThe field strength value at the location of the indoor probe.

verificationPCendpass throughField strength monitoringInstrument, adjustsignal sourceManually adjust the frequency and magnitude of the field strength.

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!