The EST-101A series high-precision gas detector is a portable handheld gas concentration measuring instrument with a replaceable probe design. It is divided into two parts: the main unit and the probe. Users only need to replace the corresponding probe to change the measuring gas. It adopts a high-precision circuit design and uses imported sensor chips as the core. After being developed and calibrated by Wanyi Technology, signal amplification, calibration, and strict testing, it is sent out of the factory.
The EST-101A multi probe gas detector mainly monitors gas types:
|
EST-101A series sensor probe selection table |
||||||
|
Sensor probe model |
Detect gas |
Standard range ppm |
Display resolution in ppm |
sensitivity ppm |
accuracy |
response time (T90) |
|
EST-101A-CH2O-1 |
formaldehyde |
0-1 |
0.001 |
0.01 |
±5%F.S. |
<50S |
|
EST-101A-CH2O-10 |
formaldehyde |
0-10 |
0.01 |
0.01 |
±5%F.S. |
<50S |
|
EST-101A-VOC-5 |
Volatile organic gases |
0-5 |
0.001 |
0.01 |
±5%F.S. |
<50S |
|
EST-101A-O3-20 |
ozone |
0-20 |
0.001 |
0.015 |
±5%F.S. |
<60S |
|
EST-101A-O3-100 |
ozone |
0-100 |
0.01 |
0.06 |
±5%F.S. |
<60S |
|
EST-101A-O3-200 |
ozone |
0-200 |
0.1 |
0.1 |
±5%F.S. |
<60S |
|
EST-101A-NH3-50 |
ammonia |
0-50 |
0.1 |
0.1 |
±5%F.S. |
<60S |
|
EST-101A-SO2-20 |
sulfur dioxide |
0-100 |
0.001 |
0.005 |
±5%F.S. |
<15S |
|
EST-101A-NO-20 |
nitric oxide |
0-20 |
0.001 |
0.015 |
±5%F.S. |
<25S |
|
EST-101A-NO2-20 |
nitrogen dioxide |
0-20 |
0.001 |
0.015 |
±5%F.S. |
<60S |
|
EST-101A-CL2-20 |
chlorine |
0-20 |
0.01 |
0.02 |
±5%F.S. |
<90S |
|
EST-101A-C2H4-10 |
ethylene |
0-10 |
0.01 |
0.1 |
±5%F.S. |
<60S |
|
EST-101A-H2S-200 |
hydrogen sulfide |
0-200 |
0.001 |
0.001 |
±5%F.S. |
<60S |
|
EST-101A-H2-5000 |
hydrogen |
0-5000 |
1 |
1 |
±5%F.S. |
<45S |
|
EST-101A-H2O2-100 |
hydrogen peroxide |
0-100 |
0.1 |
0.2 |
±5%F.S. |
<60S |
|
EST-101A-CO-500 |
carbon monoxide |
0-500 |
0.1 |
1 |
±5%F.S. |
<40S |
|
EST-101A-CO-1000 |
carbon monoxide |
0-1000 |
0.001 |
0.005 |
±5%F.S. |
<40S |
|
EST-101A-CO2-2000 |
Carbon dioxide (infrared method) |
0-2000 |
50 |
50 |
±5%F.S. |
<60S |
|
EST-101A-CO2-5000 |
Carbon dioxide (infrared method) |
400-5000 |
50 |
50 |
±5%F.S. |
<60S |
|
EST-101A-TVOC-20 |
Total volatile organic gases (PID photoionization) |
0-20 |
0.001 |
0.005 |
±3%F.S. |
<20S |
|
EST-101A-TVOC-200 |
Total volatile organic gases (PID photoionization) |
0-200 |
0.001 |
0.025 |
±3%F.S. |
<20S |
|
EST-101A-TVOC-2000 |
Total volatile organic gases (PID photoionization) |
0-2000 |
0.01 |
0.05 |
±3%F.S. |
<20S |
|
EST-101A-SF6-1000 |
Sulfur hexafluoride (infrared method) |
0-1000 |
1 |
1 |
±3%F.S. |
<20S |
|
EST-101A-SF6-2000 |
Sulfur hexafluoride (infrared method) |
0-2000 |
1 |
1 |
±3%F.S. |
<20S |
|
Note: The above is a standard gas selection, and the company supports customization. If you need to test the range of other gas types, please contact our phone number |
||||||
The instrument design and production shall comply with relevant national standards:
GB/T18883-2002 "Indoor Air Quality Standards" GB3095-1996 "Environmental Air Quality Standards"
GB50325-2010 "Code for Indoor Environmental Pollution Control of Civil Building Engineering"
GB50325-2001 Code for Indoor Environmental Pollution Control of Civil Building Engineering
GB12358-2006 "General Technical Requirements for Workplace Gas Detection and Alarm Devices" Industrial Standard
EU Directive 2002/231/CE Taiwan Indoor Air Quality Standard
EMC electromagnetic compatibility related testing standards, European standard EN55022, American standard FCC
(Note: The calibration cap can be connected to a gas sampling pump for use)
EST-101A Multi Probe Series Gas Detector Features:
- International advanced gas sensor with high accuracy, strong stability, low error rate, and good linearity.
- Advanced microprocessor, high-precision acquisition chip, unique circuit design and intelligent algorithm, faster calculation speed, more accurate measurement, and the ability to capture PPB level gas concentration changes in the air.
- Alloy probe, aviation plug, plug and play, 1-second installation, can detect dozens of gases, customers can customize various probes according to their needs.
- Configuration method LCD display, with complete parameters, can display gas types, units, 1-hour and 8-hour average values, temperature, humidity, date and time.
- This instrument has the function of viewing the average concentration values within 1 hour and 8 hours, which meets the national indoor air quality testing standards.
- Equipped with temperature and humidity measurement function, with temperature compensation, ensuring measurement accuracy even with large temperature differences.
- External power supply DC5V, built-in rechargeable 3.7V lithium battery, can be charged by connecting to an external power source.
- Supports conversion between ppm and mg/m ³ units.
- Intelligent design, automatic measurement upon startup, no need for operation, convenient zero adjustment and calibration.
- Restore factory settings function to prevent accidental operation.
- Equipped with alarm function, high and low alarm values can be set, two-level sound and light alarms, and 2 high brightness LED lights to remind users to pay attention when an alarm occurs.
- ISO9001 quality certification, ISO14001 environmental system certification, and can pass national metrology certification.
- Equipped with a calibration cap for easy calibration, optional sampling pump for safe measurement in enclosed spaces such as pipelines, tunnels, and test chambers.
|
Detection object |
optional |
External power supply |
5VDC/500mA |
|
detection |
Diffusion type |
Type |
Lithium Ion Battery |
|
Detection Principle |
electrochemistry/infrared/PID/optional |
battery voltage |
3.7V(Charging restrictions4.2V) |
|
operation temperature |
-20℃-45℃ |
Battery capacity |
1600mAh |
|
Working humidity |
0-85%RH |
ShutDown Current |
<0.1mA |
|
Display mode |
LCDLCD screen |
Power on current |
<10mA |
|
compressed air |
860-1060hpa |
alarm current |
<50mA |
|
Warm-up time |
120second |
protection grade |
dustproof |
|
response time |
T90<50S |
Alarm method |
2Level sound and light alarm |
|
service life |
Based on sensors |
alarm error |
≤±10%alarm set value |
|
zero drift |
≤±2%FS/6Month |
Data Storage |
not have |
|
Span drift |
≤±5%FS/6Month |
signal output |
not have |
|
repeatability |
≤±2% |
External dimensions |
120*60*35mm |
|
Whole machine weight |
≤250g(Including battery) |
||
Product Supporting List
1. EST-101 Gas Detector Host Unit 1
2. EST-101A sensor probe (variety and quantity customized according to customer needs) several
3. Universal 5V power adapter ... one
4. User Manual ... 1 book
5. Factory Inspection Report ... 1 copy
6. Calibration cap/protective cap (one each)
7. Portable suitcase One... one