HY-4A digital speed measuring oscillator
1: Power supply: AC 220V 50Hz 2: Motor power: 120W3: Stepless speed regulation: 0-320 times/min 4: Oscillation amplitude: reciprocating 20mm 5: Timing
Product details
HY-4 (A) Speed Regulating Multipurpose Oscillator with Digital Display, Speed Measurement, and Reciprocating Operation

HY-4A Digital Speed Measurement Oscillator Description

Multi purpose speed controlled oscillators are widely used in laboratories of various colleges and universities, environmental protection, scientific research, health, epidemic prevention, petroleum, chemical and other units. They have the characteristics of generous appearance, large capacity, low noise, light weight, small volume, adjustable speed, and timing device, making them an ideal and essential tool for laboratory staff.
Multi purpose speed regulating oscillator performance:

1Power supply: AC 220V 50Hz
2: Motor power: 120W
3: Stepless speed regulation: 0-320 times/minute
4: Vibration amplitude: reciprocating 20mm
5: Timing: Maximum 120 minutes

6: Equipped with speed digital display: 0-300 revolutions per minute

7: With A for digital speed measurement, without A for commonly used oscillating products,

Multi purpose variable speed oscillatorusage method:

1:Firstly, place the container (bottle) that needs to be oscillated into the oscillation plate spring. The solution in the container cannot exceed one-third of the container, otherwise it must be plugged.
2: Check the timer knob and turn it to the ON position or the time position you need to specify.
3: Turn the speed control knob counterclockwise to the lowest speed position, turn on the power switch, the power indicator light will turn on, and then turn the speed control knob clockwise to the speed you need.

Multi purpose variable speed oscillatormatters needing attention:

1: ThisMulti purpose variable speed oscillatorWhen using a three eye safety socket, be sure to connect the ground wire properly.
2: When working, the machine should be placed on a flat and sturdy tabletop to prevent vibration.
3: The clamp spring is only used for fixing small and medium-sized bottles, and for extra large containers, several springs should be removed or reinforced in other ways.
4: After using this machine, the power should be turned off, placed in a dry and ventilated place, and kept clean.

2、 Technical indicators of related product series:

Model specifications

HY-1

HY-2

HY-3

HY-4/KS

speed range

Starting -300rpm/min

Start up -360rpm/min

Starting -300rpm/min

Starting -300rpm/min

Amplitude

20mm

20mm

20mm

20mm

time range

0—120min(Normally open)

0—120min(Normally open)

0—120min(Normally open)

0—120min(Normally open)

External dimensions

510×480×300

520×300×240

750×500×330

440×300×240


HY-4 (A) Speed Regulating Multipurpose Oscillator with Digital Display, Speed Measurement, and Reciprocating Operation

HY-4A Digital Speed Measurement Oscillator Description

Multi purpose speed controlled oscillators are widely used in laboratories of various colleges and universities, environmental protection, scientific research, health, epidemic prevention, petroleum, chemical and other units. They have the characteristics of generous appearance, large capacity, low noise, light weight, small volume, adjustable speed, and timing device, making them an ideal and essential tool for laboratory staff.
Multi purpose speed regulating oscillator performance:

1Power supply: AC 220V 50Hz
2: Motor power: 120W
3: Stepless speed regulation: 0-320 times/minute
4: Vibration amplitude: reciprocating 20mm
5: Timing: Maximum 120 minutes

6: Equipped with speed digital display: 0-300 revolutions per minute

7: With A for digital speed measurement, without A for commonly used oscillating products,

Multi purpose variable speed oscillatorusage method:

1:Firstly, place the container (bottle) that needs to be oscillated into the oscillation plate spring. The solution in the container cannot exceed one-third of the container, otherwise it must be plugged.
2: Check the timer knob and turn it to the ON position or the time position you need to specify.
3: Turn the speed control knob counterclockwise to the lowest speed position, turn on the power switch, the power indicator light will turn on, and then turn the speed control knob clockwise to the speed you need.

Multi purpose variable speed oscillatormatters needing attention:

1: ThisMulti purpose variable speed oscillatorWhen using a three eye safety socket, be sure to connect the ground wire properly.
2: When working, the machine should be placed on a flat and sturdy tabletop to prevent vibration.
3: The clamp spring is only used for fixing small and medium-sized bottles, and for extra large containers, several springs should be removed or reinforced in other ways.
4: After using this machine, the power should be turned off, placed in a dry and ventilated place, and kept clean.

2、 Technical indicators of related product series:

Model specifications

HY-1

HY-2

HY-3

HY-4/KS

speed range

Starting -300rpm/min

Start up -360rpm/min

Starting -300rpm/min

Starting -300rpm/min

Amplitude

20mm

20mm

20mm

20mm

time range

0—120min(Normally open)

0—120min(Normally open)

0—120min(Normally open)

0—120min(Normally open)

External dimensions

510×480×300

520×300×240

750×500×330

440×300×240