Formaldmeter HTV formaldehyde detector, directly used for measuring formaldehyde concentration in the air. The HTV formaldehyde detector displays form
Product details

FormaldmeterHTV formaldehyde detectorDirectly used for measuring formaldehyde concentration in the air.HTV formaldehyde detectorDisplay formaldehyde concentration in ppm and mg/m3, unaffected by high humidity and temperature, with compensation function. The standard configuration includes a formaldehyde calibration source (valid for six months) and an operation manual, which can complete the calibration procedure in just a few seconds. It can be operated with a single button and quickly sampled. Quick recovery time, equipped with PC remote control software for data recording and real-time monitoring; We have obtained ISO 9001:2000 quality certification and comply with CE standards.

Instrument characteristics

Display formaldehyde concentration in ppm and mg/m3 units

Not affected by high humidity and temperature, with compensation function

The standard configuration includes a formaldehyde calibration source (valid for six months) and an operation manual, which can complete the calibration procedure in just a few seconds

Single key operation, able to quickly sample. Fast recovery time

Optional PC remote control software for data recording and real-time monitoring

Has obtained ISO9001:2000 quality certification and complies with CE standards, enabling the equipment to operate for a long time without any malfunctions

Instrument Specifications

The sampling method is to collect 10ml of air sample through a built-in pump

Sampling frequency 1-3 minutes (depending on the previously collected samples)

The response time is approximately 8 seconds for low concentrations and 60 seconds for high concentrations

Volume/Weight 150 × 80 × 34mm/270g with battery included

Formaldehyde sensor

Sensor: PPM company independently develops electrochemical principles

Detection range: Basic range: 0.00-10ppm (0-12.3mg/m)3Alternative range: 0.00~80ppm (0~98.3mg/m)3

Resolution: 0.01ppm

Accuracy: 2% (based on 4-5 repeated measurements taken by 12 formaldehyde analyzers)

Accuracy: 10% (According to NIOSH regulations in the United States, using acceptable measurement methods, measure formaldehyde concentration of 0.3ppm in an environment with relative humidity between 25-70%.). The acceptable standard for NIOSH is that data results within the 95% confidence interval are within ± 25% of the true value. And 94% of PPM formaldehyde detectors can meet NIOSH standards.

Temperature and humidity module

Type: Interchangeable Data CMOSens

Range: Temperature: -40 to+128 ° C Relative humidity: 0 to 100% RH

Accuracy: Temperature: ± 0.4 ° C; Relative humidity: ± 3% RH. Optional upgrade to ± 0.3 ° C, ± 1.8% RH.

Calibration: Manufacturers calibrate according to ISO/IEC 17025, traceable to NIST and the National Physical Laboratory