The device has a powerful microcomputer management platform with external software calibration function configuration, which can perform strict overlo
Product details

Product IntroductionProduct Introduction

The AC/DC indicator calibration device is a new generation portable meter source integrated meter calibration device launched by our company. This product has the characteristics of beautiful appearance, comprehensive functions, excellent indicators, high reliability, and easy operation. With this device, it is possible to calibrate various types of voltmeters, ammeters, single-phase power meters, three-phase active and reactive power meters, phase meters, power factor meters, frequency meters, synchronous meters, and various types of electric energy meters at or below level 0.5 without the need for additional standards.

Product Name: AC/DC Indicator Calibration Device, Multi functional AC/DC Indicator Calibration Device, AC/DC Indicator Calibration Device, AC/DC Indicator Calibration Device, Multi functional AC/DC Indicator Calibration Device

Product parametersProduct Parameters

Technical Parameter

voltage Communication range Basic range: 25V, 100V, 250V, 600V
Automatic range: 15V~600V
DC range Basic range: 100mV, 25V, 100V, 250V, 600V
Automatic range: 15V~600V
Adjustment range 0~130% UN
Regulating fineness 0.002%UN
Maximum output capacity ≥ 20VA/phase
Precision 0.1 level
electric current Communication range Basic range: 0.1A, 1A, 5A, 25A
Automatic range: 0.05A~25A
dc test Basic range: 20 μ A, 200 μ A, 2mA, 20mA, 0.1A, 1A, 5A, 25A
Automatic range: 20 μ A~20mA and 0.1A~25A
Adjustment range 0-130% IN (25A gear, 0-120%)
Regulating fineness 0.002%IN
Maximum output capacity ≥ 20VA/phase
Precision 0.05 level
frequency Adjustment range 40Hz~70Hz
Regulating fineness 0.01Hz
Setting value accuracy ±0.01Hz
phase Adjustment range 0~359.99°
Regulating fineness 0.01°
accuracy ±0.4°
(When the rated voltage and current are output at full range) Three phase power accuracy
0.05 level (reactive power is 0.2 level) Symmetry of three-phase voltage
Three phase four wire 120 °± 0.2 ° Three phase three wire 60 °± 0.2 °
Distortion of voltage and current waveforms < 0.3%
Voltage, current, and power stability ≤ 0.01% (1 minute)
measurement accuracy 0.01 level (0~± 20mA, 0~± 5V)
Comprehensive error of the device 0.1%
weight 18kg
volume 432×428×175mm
power supply

220V±10%

Note:

1. The appearance of the product is subject to the actual product. Technical parameters and models are subject to change without prior notice. If there is any act of theft or copying, legal responsibility will be pursued.2. To learn more about Huatian products, please enter the product center. Service Hotline: 400-8855-448

  • Product Features
  • Product Characteristics
  • 1. The digital signal synthesis and data acquisition processing technology based on DSP ensures stable and reliable output of the device.
  • 2. The comprehensive error of the AC/DC indicator calibration device is 0.05 level, with high accuracy and excellent indicators.
  • 3. Equipped with a powerful microcomputer management platform, it can perform microcomputer verification, transmission, printing, and data management.
  • 4. The voltage and current ranges can be set according to the tested meter and automatically shift gears.
  • 5. Large screen LCD display, pop-up Chinese menu, cursor can be moved freely, providing online help prompts, easy operation, and rich display content.
  • 6. It can output AC/DC voltage and current, equipped with power, frequency, phase, power factor, and AC/DC voltage and current standards. During calibration, it can display both primary and secondary values, automatically calculate and display calibration errors, and store and preview calibration results.
  • 7. 2-31st harmonic output can be set to facilitate harmonic testing of various instruments.
  • 8. The AC/DC indicator calibration device has an external software calibration function.
  • 9. Strong load capacity, can directly carry 1 μ F capacitor (100V range).
  • 10. Multiple protections: power linkage protection, current limiting protection, automatic shutdown of amplifier output, etc.
交直流指示仪表校验装置

11. Strict overload test, shock test, misoperation test, high temperature aging test, with exceptionally good reliability.12. German standard chassis, small size, light weight, easy to carry.

Product Atlas

Product Picture

Product Attachment Diagram

Instrument host

交直流指示仪表校验装置电源线

TEST

交直流指示仪表校验装置说明书、检验报告、合格证

Interface cable

power line

Instruction manual, inspection report, certificate of conformity

Product detail diagram

host

Side of the host

Back of the host

panel

交直流指示仪表校验装置主机测试线插孔

Panel interface

交直流指示仪表校验装置主机数据线接口

Key control area

Test line socket

Data cable interface

screen

Local buttons

power switch

Back socket

Cooling window

交直流指示仪表校验装置主机转接头

accessory kit

交直流指示仪表校验装置主机转接头

Test clip

交直流指示仪表校验装置主机光盘

Adapter

交直流指示仪表校验装置接口线接头

Adapter

交直流指示仪表校验装置测试线插头

light disk

Interface cable connectorTest line plug

product certificate

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!