HT-VOC-2000F Volatile Organic Compounds Online Monitoring System
Product Overview: HT-VOC-2000F Volatile Organic Compound Emission Continuous Online Monitoring System (hereinafter referred to as HT-VOC-2000F System)
Product details
Product Overview
The HT-VOC-2000F volatile organic compound emission continuous online monitoring system (hereinafter referred to as the HT-VOC-2000F system) can continuously monitor methane/non methane total hydrocarbons, benzene derivatives, characteristic factors, particulate matter concentration, flue gas temperature, pressure, flow rate related parameters in real time online, and calculate emission rates, total emissions, etc., so as to effectively manage the measured data. The HT-VOC-2000F system has functions such as real-time transmission of on-site data, remote fault diagnosis, report statistics, and graphical data analysis. It has flexible networking and low operating costs. At the same time, the system adopts a modular structure, which is easy to combine and can fully meet the communication requirements with the internal DCS system and environmental protection department data system of the enterprise.
Product advantages
Adopting EPC technology for carrier gas pressure and hydrogen and air flow rates, with high accuracy;
Using low maintenance diaphragm pumps and quantitative rings for volumetric sampling;
Adopting imported VALCO ten way/six way valves, with low maintenance and long service life;
Using double column parallel blowback technology to analyze non methane total hydrocarbons, reducing peak broadening and shortening analysis time;
Adopting a miniature FID detector with higher sensitivity than conventional FID detectors;
19 'standard chassis, compact structure, can be integrated with instruments of the same type and installed in a vertical cabinet, occupies a small area, and is easy to maintain and operate on a daily basis. Built in standard industrial PC, high-definition color LCD touch screen, excellent human-computer interaction control software interface, based on Microsoft Windows operating system, can achieve automatic unmanned operation of the entire system.
Technical Specifications

size
Standard chassis, height 5U
power supply
220VAC,50Hz
power
< 500VA (starting less than 1000VA)
Operating Temperature
(5-35)℃
humidity
(20-90)%RH
detector
High sensitivity FID detector
detection limit
Methane: 0.1ppm
Non methane total hydrocarbons: 0.05ppm
Benzene derivatives: 0.1ppm
range
Non methane total hydrocarbons: 0-100/200/1000ppm (configurable)
Benzene derivatives: 0~20/50/100ppm (configurable)
Analysis cycle
5-minute (adjustable)
Sample gas temperature
160 ℃ (adjustable)
reproducibility
≤3%

Application field
petrochemical
electronics industry
medicine
rubber products
Organic solvent manufacturing
spraying
automobile manufacturing
printing