The OPTI-LYNX quick connect system manually tightens the right angle rotary seal sleeve with a low volume/low dispersion interface in the critical are
Product details

OPTI-LYNX™Quick connect system

  • Manually tighten the right angle rotary sealing sleeve
  • Low volume in the critical volume region/Low dispersion interface
  • True zero dead volume connection
  • Online and direct connection card sleeve design
  • Card sleeve hardware only needs to be tested once
  • No tools required, manually tighten
  • Simple, innovative, and easy to use

widely used

OPTI-LYNX is the first to introduce HPLC and HPLC/MS low dispersion rapid connection systems, making it the most effective solution for high-throughput and single instrument laboratories. The system is simple, fast, and easy to use.

The OPTI-LYNX system is designed with modularity and strong versatility. The OPTI-LYNX accessory can be used with filters, protective columns, capture columns, or analytical columns. The end cap of the card sleeve is a surface with the same characteristic interaction, and only the card sleeve needs to be replaced. To install a protective column, simply unscrew the previous front column filter. If you want to use directly connected filters with different porosities and diameters, simply replace the embedded parts. It can be easily switched on and off in various application scenarios or any place where liquid pipeline connections need to be frequently interrupted. OPTI-LYNX is flexible to use and does not require any changes.

Can be replaced without any toolsOPTI-LYNX ™ plugin

working principle

useOPTI-LYNX, Simply manually rotate a quarter turn to immediately complete or disconnect the pipeline connection. The OPTI-LYNX connection is made by assembling two components (slotted edge and fixed edge) together and connecting them to the joint. The OPTI-LYNX system combines practicality and versatility, as the connectors can be replaced with filters, capture columns, protective columns, and even analytical columns. Almost any component in the HPLC flow path can be assembled into the OPTI-LYNX insert.


OPTI-SOLV®Online filter

rated pressure6000psi(400)bar


The OPTI-SOLV online filter is installed between the pump and the sampler/automatic sampler, which can protect downstream components and avoid instrument shutdown and manual operation.

Just tighten by handPEEK fasteners can achieve high-pressure sealing. There are also stainless steel models available for wrench fastening. OPTI-SOLV is suitable for various application environments, such as high temperature environments.

OPTI-SOLV ® Online filter set

10-04-02372 0.2 μ m, PEEK online filter (hand tight)

10-04-02371 0.2μm, Stainless steel online filter (wrench fastened)

10-04-00386 0.5 μ m, PEEK online filter (hand tight)

10-04-00383 0.5μm, Stainless steel online filter (wrench fastened)

10-04-00391 2 μ m, PEEK online filter (hand tight)

10-04-00390 2μm, Stainless steel online filter (wrench fastened)

*The above sets all include card sleeves, accessories, and 2 sieve plates

OPTI-SOLV ® Online filter card sleeve

10-04-03685 PEEK card sleeve (hand tight)

10-04-03686 Stainless steel card sleeve (tightened with wrench)

OPTI-SOLV ® sieve plate

10-04-02370 0.2μm, 0.187' Dia. 筛板, 10/Pk

10-04-03699 0.5μm, 0.062' Dia. 筛板, 10/Pk

10-04-03701 0.5μm, 0.125' Dia. 筛板, 10/Pk

10-04-00100 0.5μm, 0.187' Dia. 筛板, 10/Pk

10-04-03700 2μm, 0.062' Dia. 筛板, 10/Pk

10-04-03702 2μm, 0.125' Dia. 筛板, 10/Pk

10-04-00103 2μm, 0.187' Dia. 筛板, 10/Pk


OPTI-SOLV®micro filter

rated pressure6000psi(400)bar

The OPTI-SOLV micro filter provides low impact filtration, with a volume similar to that of a hand grip accessory. The use of micro filters can extend the lifespan of analytical columns and prevent small particle damage to mass spectrometers.

Through patented automatic depth adjustment of pipe stop, perfect zero dead volume connection can be achieved every time. The unique deep filtering element supports larger capacity without bandwidth expansion or performance loss. Efficient design allows direct access to any device without the need for clamps or threads10-32 interface.

Ordering Information

OPTI-SOLV ® micro filter

10-04-00095 OPTI-SOLV Micro Filter, 0.5 μ m, 5/Pk

10-04-00097 OPTI-SOLV Micro Filter, 2.0 μ m, 5/Pk

10-04-02768 OPTI-SOLV Micro Filter, 5.0 μ m, 5/Pk


OPTI-SOLV®miniature/Micro/Nano Filters:


  • Design filter particles to effectively extend the service life of the column
  • Perfect zero dead volume connection every time
  • Floating valve stem can automatically adjust at any depth interface
  • No need to use tools
  • The rated pressure is 6000 psi

OPTI-SOLV®Micron filter

rated pressure6000psi(400)bar

The OPTI-SOLV micro filter is designed for filtration with volume requirements. Based on the design of micro filters, micro filters reduce the internal volume to below 200nL while retaining the ease of use and functionality of micro filters.

Micro filters are used for low volume, high-sensitivity chromatographic applications as the last line of defense against debris. Like all protective products,The OPTI-SOLV micro filter adopts patented floating rod (automatic adjustment) technology to achieve zero dead volume connection.

Ordering Information

OPTI-SOLV ® Micron filter

10-04-03621 OPTI-SOLV Micron Filter, 0.5 μ m, 5/Pk

10-04-03357 OPTI-SOLV Micron Filter, 1.0 μ m, 5/Pk

10-04-03389 OPTI-SOLV Micron Filter, 2.0 μ m, 5/Pk

10-04-03707 OPTI-SOLV Micron Filter, 10 μ m, 5/Pk

OPTI-SOLV ® Biocompatible Micron Filter

10-04-03936 OPTI-SOLV Biocompatible Micro Filter, 0.5 μ m, 5/Pk

Liquid receiving materialPEEK and titanium metal

OPTI-SOLV ® Nano filter

rated pressure6000psi(400)bar

The internal volume of the OPTI-SOLV nanofilter is less than 50nL, making it an ideal choice for mass spectrometry analysis

Optional, it can protect the top of electric spray and nano spray from being blocked by debris.

Ordering Information

OPTI-SOLV ® Nano filter

10-04-03625

OPTI-SOLV Nano Filter, 0.5 μ m, 5/Pk

OPTI-SOLV ® Biocompatible Nanofilter

10-04-03939

OPTI-SOLV biocompatible nanofilter, 0.5 μ m, 5/Pk

Liquid receiving materialPEEK and titanium metal

OPTI-TRAP™

rated pressure6000psi(400)bar

OPTI-TRAP is a bidirectional capture card system that can be used individually or in series for sample concentration and purification. The OPTI-TRAP system is composed of a durable biocompatible trap jacket, which is made entirely of PEEK (capillary structure) or stainless steel with PEEK flow paths (micro and macro structures). OPTI-TRAP has low back pressure and can be manually loaded and eluted using a syringe, or injected into the injection valve online through a syringe.

OPTI-TRAPs contain titanium sieve plates that are fully biocompatible.


OPTI-TRAP ™ the advantage of

  • The rated operating pressure of the hand grip can reach1,500 psi (100 bar)
  • Low back pressure, used for loading syringes/Elution or online capture
  • Transparent card sleeve for visual inspection of column bed
  • Bidirectional card sleeve for flushing and bed regeneration
  • Color coded tape is used to identify the type of filler


OPTI-LYNX™ MICRO

The OPTI-LYNX Micro has convenient quick connect card sleeves, providing a variety of filling card sleeve options for chromatographs. Multiple specifications are available for online and offline sample pre concentration and cleaning. The external dimensions of each card sleeve are the same, allowing different sizes and porosity to be used in the same card sleeve hardware. There are two styles of card sleeves available at the same time. The OPTI-LYNX Micro online card sleeve provides complete biocompatibility, while the direct threaded design facilitates access to all 10-32 interfaces.

The OPTI-LYNX capture column is an ideal tool for optimized capture technology. Whether separating peptide hydrolysate from its matrix for further analysis or preparing diluted small molecule samples for liquid phase injection without losing the sample, these chromatographic columns can be loaded at maximum and regenerated repeatedly.

OPTI-LYNX ™ Advantages of Micro

  • Hand tight quick connection(Right angle rotation) system
  • The rated pressure is6000psi, No tools needed
  • online(BC) and direct connection configuration
  • Oil biocompatible bidirectional sleeve
  • New compact design reduces back pressure

OPTI-LYNX ™ Micro card sleeve

11-04824-AA OPTI-LYNX Micro direct connect card sleeve, including rear end accessories

11-03924-AA OPTI-LYNX Micro online card sleeve, including accessories and column tubes


OPTI-GUARD®Protection column

The analytical column is the core of the liquid chromatography system and also the most problematic part. The accumulation of fragment impurities in high-performance liquid chromatography columns can significantly reduce the service life of the analytical column, causing equipment shutdown, column failure, or other malfunctions.

Why do we need to protect the pillar

The best way to protect the analytical column from contamination is to use a protective column between the injector and the analytical column. The protective column can capture particles, solvent impurities, and retained sample components. The ideal protective column should not affect the separation efficiency of the analytical column. Therefore, in order to achieve the best results, protective pillars that match the bonding and the best hardware configuration should be selected.

Extra column volume

The application requirements of high-performance liquid chromatography are becoming increasingly stringent, such as smaller column bed volume, higher pressure, and higher sensitivity, therefore, better design of the protective column is needed. However, many manufacturers of protective columns overlook the dead volume that occurs when the protective column or sleeve is connected to the analytical column. Using preloading or integral nuts and clamps to design and secure the pipe rod will increase additional column volume(displayed in blue), and affects the column ratio. (Figure 1)

And other card sleeve protection columns require additional connectors and column tubes, which will also increase the additional column volume and reduce the overall performance of the system. (Image)2)

OPTI-GUARD® 1MM

OPTI-GUARD is a standard low impact, easy-to-use pre column protective column. The OPTI-GUARD is designed for conventional analysis columns (4.6mm, 3.0mm inner diameter) and narrow inner diameter analysis columns (2.1, 1.0mm inner diameter). The patented floating valve stem design can automatically adjust the pipe stopping depth after connecting any column tube, achieving true zero dead volume connection. The volume of OPTI-GUARD is the same as standard accessories. The filling material inside can be customized. ’

OPTI-GUARD ® 1mm protective column

10-02-00007 C18, 5/Pk

10-02-00010 C8, 5/Pk

10-02-03211 C4, 5/Pk

10-02-00014 Silica, 5/Pk

10-02-00018 Phenyl, 5/Pk

10-02-00022 Cyano/CN, 5/Pk

10-02-00026 Amino/NH2, 5/Pk

10-02-00030 Anion Exchange Filler, 5/Pk

10-02-00034 cation exchange filler, 5/Pk

10-02-04068 DVB, 5/Pk

10-02-03463 Customized Filler, 5/Pk

10-02-01714 Technical Development Kit, 5/Pk

OPTI-GUARD ® 1mm biocompatible protective column

10-02-03532 Biocompatible C18, 5/Pk

10-02-04708 Biocompatible C8, 5/Pk

10-02-03534 Biocompatible Silicon, 5/Pk

10-02-03538 Biocompatible Cyano/CN, 5/Pk

10-02-03536 Biocompatible Amino/NH2, 5/Pk

10-02-03680 Biocompatible Anion Exchange Filler, 5/Pk

10-02-03683 Biocompatible Cation Exchange Filler, 5/Pk


OPTIBack pressure regulator

The OPT flow-through back pressure regulator utilizes an active mechanism to maintain stable back pressure within the viscosity and flow rate range of the mobile phase. Placing a back pressure regulator downstream of the detector can prevent solvent depressurization and bubbles in the flow chamber, reducing baseline noise and drift.

The internal volume of each regulator is100μL, The preset pressures are 10 psi, 30 psi, 60 psi, 100 psi, and 150 psi.


Back pressure regulator

10-06-00120 Back pressure regulator, 10 psi

10-06-00128 Back pressure regulator, 30 psi

10-06-00129 Back pressure regulator, 60 psi

10-06-00130 Back pressure regulator, 100 psi

10-06-00132 Back pressure regulator, 150 psi

*All regulators include accessories