Product details


1Equipment Composition


IIEquipment principle

portable(Handheld) Doppler ultrasoundopen channelA flowmeter utilizes the Doppler effect of sound waves propagating in a fluid to measurecalmflow

bodyDoppler frequency shift of sound waves scattered by medium motion particlescomeObtain the velocity of the fluid, combined with the built-in pressure type water level gauge, and utilize the velocity surfaceamass

The law,It can measure the flow rate of the liquid. HMIwithinStorage spaceUp to 16MB, capable of storing over 100000 pieces of data, with built-in high-performance lithium batteries

Pool,oneThe second charge can work continuously for more than 12 hours, equipped with a LCD display screen that can display the flow rate in real timewater levelinternet trafficWaiting for data.

Average flow velocity measurementThe measurement of flow velocity is achieved by emitting and receiving ultrasonic signals through an ultrasonic probe (transducer) and performing corresponding measurements

countObtained through computational processing:transducer1The transmission frequency isf1Ultrasonic signals are emitted from underwater at a certain angle towards the surface of the water, and upon contact

watercentreAfter the suspension of particles or bubbles, the frequency shifts andf2The frequency is reflected back to the transducer2That's moreuniversalLe Bian,f2

givef1thisDifference is moreuniversalLe frequency differencefdLet the fluid flow rate bevThe ultrasonic velocity isc, manyuniversalLe frequency shiftfdProportional to fluid velocityv.

waterThere will beA large number of impurity particles and bubbles, each reflecting particle corresponds to more than oneuniversalLe frequency shiftfdBy conversion, the flow velocity can be obtained,

These large quantitiesThe average velocity of particles, also known as the average velocity of fluids.

IIIApplication scope

lakesReservoir, river water intake, urban drainage network, rainwater network

Agricultural irrigation Sewage discharge

Water supply and diversion channels, livestock farms, and factories discharge pollutants

4equipment installation


5、 Equipment features

1. It can measure the flow rate of non full pipes (round pipes, egg shaped pipes, or other irregular pipes);
2. It can measure the flow rate of channels (circular channels, rectangular channels, or other irregular channels);
3. It can measure the natural flow of rivers and streams;
4. It can measure the flow rate of sewage discharge channels or pipelines (sewers);
5. Can provide instantaneous and cumulative flow values;
6. The instrument is equipped with a built-in data storage device;
7. The sensor can work for a long time in harsh environments and sewage quality;
8. Optional SMS or GPRS wireless module for remote telemetry.


·Flow rate:

·Range: 20mm/s to 6000mm/s.
·Accuracy: ± 1% of the measured flow rate.
·Resolution: 1mm/s.

·Temperature:
·Range: 0 ℃ to 60 ℃.
·Resolution: 0.2 ℃.

·Water level:
·Range: 0-10m.
·Resolution: 1 mm.
·Accuracy: ± 0.5% of the measured water level.

·Traffic:
Accuracy: ± 2% of the measured flow rate.

·Power supply:
12V DC or 220V AC.

·Output interface:
Standard RS232, RS485, 4-20mA.

·Communication protocol:
Modbus。

·Data storage capacity:
Collect one record every minute and store data for more than 6 months.

·Operating temperature:
The water temperature ranges from 0 ℃ to 60 ℃.

·Shell material:
PC or PVC plastic.

·Shell protection level:
IP68。

·Reliability:
MTBF≥25000h。

·Measuring rod length:
4 meters, 6 meters.
Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content