APS-7200/7300 Programmable AC Power Supplycharacteristic
• Output capacity: APS-7200(2000VA、310Vrms、16.8Arms)/ APS-7300 (3000VA、310Vrms、25.2Arms)。 The output can be expanded to (0~600Vrms/45~999.9Hz) through optional accessories.
ARB waveform output, Surge/ Dip control
The measurement function includes VOLT CURR、PWR、SVA、IPK、IPKH、FREQ、PF、CF
10 sets of Sequence functions allow editing of output waveforms/10 sets of Simulate mode for fast simulation of power transients/10 sets of Program mode for custom measurement sequence/10 sets of panel memory function
• Support automatic execution of Sequence, Simulate, Program mode, and output functions upon startup
• Standard interface: USB Host, USB Device, LAN
Optional interface: GPIB (APS-001); RS232(APS-007)
Guwei Electronics has launched the APS-7200&7300 AC power supply. The maximum rated output of APS-7200 is 2000VA and 310Vrms 16.8Arms; APS-7300 is 3000VA, 310Vrms, 25.2Arms, with an output frequency of 45.00~500.0Hz. The output voltage of 0-600Vrms and the output frequency of 45-999.9Hz can be directly expanded at the user end through optional methods, without the need for factory modifications. Suitable for testing and development of AC-DC power supply devices, consumer electronics products, automotive electronics, and electronic components.
APS-7200&7300 have a total of 9 measurement items (Vrms, Irms, F, Ipk, W, VA, PF, Ipk hold, CF) in terms of measurement functions, and provide an approximate AC Power Meter operation interface, suitable for LED industry or standby power consumption measurement. In ARB mode, APS-7200&7300 provide SINE waveform Triangle waveform、Staircase waveform、Clipped Sinewave、Crest factor waveform、Surge waveform And Fourier series has nearly 20000 types of combined waveforms in seven major categories, which can meet the testing needs of various industries in simulating abnormal waveforms of input power supplies. 10 sets of Preset settings, allowing users to store ten sets of settings; The Power ON Output setting allows Sequence, Simulate, and Program to automatically execute output after startup.
In order to meet the testing conditions of common input power supply changes in consumer electronic products, APS-7200&7300 provides five ways to respond to special or abnormal voltage, frequency, and phase changes, with 10 sets of Simulate simulating power interruption, voltage increase, or voltage decrease behavior; 10 sets of sequences for users to customize parameters and generate sine waves through steps editing; 10 sets of programs are used to edit the output of AC waveforms, and can also customize the upper/lower limits of measurement items for different DUTs; Ramp Control allows users to set the speed at which the output voltage rises and falls; Surge/DIP Control can simulate the input power supply of DUT generating a Surge or Dip voltage superimposed on the output voltage waveform at a specific time. APS-7200&7300 not only provide OCP/OPP/OTP protection, but also display the front panel reading in red font to remind users when a voltage current phase difference of 180 degrees (reverse current) is detected at the output end of the back panel. It is suitable for inverter feedback grid testing, where the current measurement results of the feedback grid are displayed.
The APS-7200&7300 backplate Ethernet Port can be remotely programmed, the Sync Output Socket provides 10V output voltage for external synchronization, and the Signal Output connector provides monitoring of program execution results. APS-7200&7300 also provide Trigger In/Out and Output on/off remote control functions, which can be used by customers on the J1 connector on the back panel.
APS-7200/7300 AC power specifications
model |
APS-7200 |
APS-7300 |
||
power input | ||||
phase |
Single Phase |
|||
Input power supply |
230Vac ± 15% |
|||
input frequency |
50/60Hz |
|||
Maximum current |
32A |
50A |
||
apparent power |
7.2KVA or less |
10.8KVA or less |
||
Power factor |
0.7 Typ. |
|||
AC output | ||||
rated power |
2000VA |
3000VA |
||
Output voltage |
0 ~ 155Vrms, 0 ~ 310Vrms |
|||
OUTPUT FREQUENCY |
45.00 ~ 500.0 Hz |
|||
Maximum current (effective value) * 1 |
0 ~ 155 Vrms |
16.8A |
25.2A |
|
0 ~ 310 Vrms |
8.4A |
12.6A |
||
Maximum current (peak value) |
0 ~ 155 Vrms |
Peak value which is four times of the maximum current |
||
0 ~ 310 Vrms |
Peak value which is four times of the maximum current |
|||
phase |
Single Phase, Two Wire (1P2W) |
|||
Total Harmonic Distortion (THD) * 2 |
≤ 0.5% at 45 ~ 500.0Hz (Resistive Load) |
|||
crest factor |
≧ 4 |
|||
Power regulation rate |
0.1% (% of full scale) |
|||
Load regulation rate |
0.5% (% of full scale) |
|||
reaction time |
< 100µS |
|||
Reverse Current |
30% of Maximum Output RMS Current (Continue) |
|||
setting | ||||
voltage |
range |
0 ~ 155Vrms, 0 ~ 310Vrms, Auto |
||
resolution |
0.01V at 0.00 ~ 99.99Vrms |
|||
accuracy |
± (0.5% of setting + 2 counts) |
|||
frequency |
range |
45 ~ 500 Hz |
||
resolution |
0.01Hz at 45.00 ~ 99.99Hz |
|||
accuracy |
± 0.02% of Setting |
|||
Power on/off phase angle |
range |
0 ~ 359° |
||
resolution |
1° |
|||
accuracy |
± 1° (Only 45 ~ 65Hz) |
|||
Measurement * 3 | ||||
Voltage (effective value) |
range |
0.20 ~ 38.75Vrms |
||
resolution |
0.01V at 0.00 ~ 99.99Vrms |
|||
Accuracy * 4 |
± (0.5% of reading + 2 counts) |
|||
frequency |
range |
45 ~ 500Hz |
||
resolution |
0.01Hz at 45.00 ~ 99.99Hz |
|||
accuracy |
± 0.1Hz |
|||
Current (effective value) |
range |
0.200 ~ 3.500A |
||
resolution |
0.001A |
|||
accuracy |
± (0.5% of reading + 5 counts) , 0.200 ~ 3.500A |
|||
Current (peak value) |
range |
0.0 ~ 140.0A |
||
resolution |
0.1A |
|||
accuracy |
± (1% of reading + 1 counts) |
|||
Power (W) |
resolution |
0.1W |
||
accuracy |
± (0.6% of reading + 5counts) , 0.2 ~ 999.9W |
|||
Apparent power (VA) |
resolution |
0.1VA |
||
accuracy |
± (1% of reading + 7 counts) , 0.2 ~ 999.9VA |
|||
Power factor |
resolution |
0.001 |
||
accuracy |
±2% reading + 2 counts |
|||
general | ||||
Remote output signal |
Pass, Fail, Test-in Process, Trigger in, Trigger out, OUT ON/OFF |
|||
Trigger Output |
Maximum low level output = 0.8V |
|||
Trigger Input |
Maximum low level input voltage = 0.8V |
|||
Synchronous output signal |
Output Signal 10 V, BNC Type |
|||
Preset group (number) |
10 (0~9 numeric keys) |
|||
protect |
OCP, OPP, OTP and Alarm |
|||
environmental condition |
Operating temperature range |
0 ~ +40 ℃ |
||
Storage temperature range |
-10 ~ +70 ℃ |
|||
Operating humidity range |
20 ~ 80% RH (no condensation) |
|||
Storage humidity range |
|
80% RH or less (no condensation) |
||
LCD panel display |
4.3 inch, 480 (RGB) x 272 |
|||
Size (mm) |
wide |
430 |
430 |
|
tall |
312 |
400 |
||
deep |
650 |
650 |
||
weight |
90Kg |
128Kg |
||
SEQUENCE / SIMULATION FUNCTION | ||||
Memory (number) |
10 (0~9 numeric keys) |
|||
Step order |
255 max. (for 1 sequence) |
|||
Step time range |
0.01 ~ 999.99 S |
|||
Step wise execution method |
Constant, Keep, Linear Sweep |
|||
parameter |
Ouptut Range, Frequency, Waveform (sine wave only), On Phase, Off Phase, Term Jump Count (0 ~255), Jump-to, Branch 1, Branch 2, Trigger Output |
|||
program control |
Start, Stop, Hold, Continue, Branch 1, Branch 2 |
|||
interface | ||||
standard |
USB Host, USB CDC, LAN |
|||
Optional |
GPIB (APS-001) |
|||
| ||||
Optional APS-003(Output voltage 0~600Vrms | ||||
model |
APS-7200 |
APS-7300 |
||
Output | ||||
rated power |
2000VA |
3000VA |
||
Maximum current (effective value) * 5 |
0 ~ 600 Vrms |
4.2A |
6.3A |
|
Maximum current (peak value) |
0 ~ 600 Vrms |
Peak value which is four times of the maximum current |
||
Setting up | ||||
voltage |
range |
0 ~ 155Vrms, 0 ~ 310Vrms, 0 ~ 600Vrms, Auto |
||
resolution |
0.01V at 0.00 ~ 99.99Vrms |
|||
Accuracy * 6 |
± (0.5% of setting + 2 counts) |
|||
measure | ||||
Voltage (effective value) |
range |
0.2 ~ 600.0Vrms |
||
resolution |
0.01V at 0.00 ~ 99.99Vrms |
|||
accuracy |
± (0.5% of reading + 2 counts) |
|||
| ||||
Optional APS-004(Output frequency 45~999.9Hz) | ||||
model |
APS-7200 |
APS-7300 |
||
Setting up | ||||
frequency |
range |
45.00 ~ 999.9Hz |
||
resolution |
0.01Hz at 45.00 ~ 99.99Hz |
|||
accuracy |
± 0.02% of Setting |
|||
Measurement | ||||
frequency |
range |
45.00Hz ~ 999.9Hz |
||
resolution |
0.01Hz at 45.00 ~ 99.99Hz |
|||
accuracy |
± 0.1Hz |
|||
Total Harmonic Distortion (THD) * 7 |
≤ 0.5% at 45 ~ 999.9Hz (Resistive Load) |
(This specification is applicable after 30 minutes of heating and in an environment between 18 and 28 degrees C.)
Attachment information
CD (manual, program control manual) x 1
quick guide
GTL-123 Test Line
power cord, 8mm2/3C, 3M length, 105℃