VIP member
Guangdong Xingning UV Disinfector
The Guangdong Xingning ultraviolet disinfection equipment is suitable for sterilizing purified water quality, such as tap water, purified water, aquac
Product details
UV sterilizer (UV sterilizer)Adopting specially designed high-efficiency, high-strength, and long-life ultraviolet radiationCStrong ultraviolet radiation generated by the light generating deviceCLight shines on flowing water.The treated water isUV sterilizer (UV sterilizer)The inlet enters the reactor and flows through the reaction chamber at a certain speed, producing microorganismsDNATheRNAThe internal structure has been damaged and cannot be replicated, thus meeting national inspection standards without the use of any chemical drugs.And wavelength185nmThe spectral lines can also decompose organic molecules in water, generate hydrogen radicals, and oxidize organic molecules in water to carbon dioxide, achieving removalTOCThe purpose.
UV sterilizer (UV sterilizer)Product features:
304or316Polishing stainless steel;
·Quartz sleeve to ensure the highest UV transmittance;
High output, using hard glass ultraviolet lamps to achieve maximum efficiency;
·Sound and visual lighting alarm devices;
·A precise nanometer ultraviolet monitoring device is composed of various output devices, including light-emitting diodes and measuring instruments;
·The all stainless steel shell is treated with anodic rust prevention;
Using thermistor to control the control board and reactor;
·Using an electronic timer;
·Solenoid valves and remote control equipment, including infrared output devices;
The equipment is clean, electroplated and polished, suitable for high purification environments;
·The electrical configuration of the equipment is suitable for markets around the world;
Specially designed appearance, more convenient to use.
UV sterilizer (UV sterilizer)Purpose and classification of equipment
1UV sterilizer (UV sterilizer)The removal rate of various viruses and bacteria from treated seawater, freshwater or other water bodies can reach99.99%The above.
2·The removal rate of viruses and bacteria in water reaches99.99%Under the above premise, the cost per ton of water treatment is4Li here1Splitting money in RMB (depending on the cleanliness of the water body).
3·Improving the survival rate of seawater and freshwater seedlings and aquaculture to this day50%Above (depending on the survival rate without sterilization)
4·Accelerate the growth rate of aquaculture populations.
5·Improve the overall health level of seedlings and breeding populations, cultivate healthy seedlings and healthy adults.
6·Without changing the original ingredients, taste, and color of various beverages and other fluid foods, the removal rate of pathogenic bacteria and other pathogens can reach99.99%The above.
7·Using ultraviolet pre sterilization treatment for swimming pool water can reduce the chlorine content in the water0.5milligram/Improve the removal rate of viruses and bacteria99.99%The above.
8·Adding UV sterilization to the application water terminal can achieve the standard of directly using water.
9·Sterilize urban sewage and reduce the total bacterial count to200a/100mlBelow, Escherichia coli20a/100mlfollowing.
UV sterilizer (UV sterilizer)Equipment model parameters:
| model |
water treatment capacity T/H |
Imported pipe diameter mm |
power W | Overall dimensions |
work pressureMPa
|
| Φ×L | |||||
| GY55-4 | 18-20 | 80 | 220 | 219×1300 | 0.6 |
| GY55-5 | 22-25 | 80 | 275 | 219×1300 | 0.6 |
| GY55-6 | 30-35 | 100 | 330 | 219×1300 | 0.6 |
| GY55-8 | 45-48 | 100 | 440 | 250×1300 | 0.6 |
| GY55-10 | 70-75 | 125 | 550 | 250×1300 | 0.6 |
| GY75-4 | 25-30 | 80 | 300 | 219×1660 | 0.6 |
| GY75-5 | 35-40 | 100 | 375 | 219×1660 | 0.6 |
| GY75-6 | 45-50 | 100 | 450 | 219×1660 | 0.6 |
| GY75-7 | 55-58 | 125 | 525 | 250×1660 | 0.6 |
| GY75-8 | 60-65 | 133 | 600 | 250×1660 | 0.6 |
| GY75-9 | 70-80 | 150 | 675 | 300×1660 | 0.6 |
| GY75-10 | 80-100 | 150 | 750 | 300×1660 | 0.6 |
| GY150-4 | 75--80 | 133 | 600 | 219×1660 | 0.8 |
| GY150-5 | 90-110 | 150 | 750 | 219×1660 | 0.8 |
| GY150-6 | 120-130 | 150 | 900 | 250×1660 | 0.8 |
| GY150-7 | 140-160 | 150 | 1050 | 250×1660 | 0.8 |
| GY150-8 | 170-180 | 200 | 1200 | 300×1660 | 0.8 |
| GY150-9 | 200-210 | 200 | 1350 | 300×1660 | 0.8 |
| GY150-10 | 230-240 | 200 | 1500 | 350×1660 | 1.0 |
| GY150-11 | 260-280 | 250 | 1650 | 350×1660 | 1.0 |
| GY150-12 | 300--320 | 250 | 1800 | 350×1660 | 1.0 |
| GY300-8 | 400-430 | 250 | 2400 | 350×1660 | 1.0 |
| GY300-10 | 460-510 | 250 | 3000 | 350×1660 | 1.0 |
| GY300-14 | 600-650 | 300 | 4200 | 400×1660 | 1.0 |
| GY300-20 | 800-900 | 350 | 6000 | 500×1660 | 1.0 |
Attachment:1The equipment provided in this technical parameter table is suitable for sterilization of purified water quality, such as tap water, purified water, aquaculture water, food processing water, differentiated water supply, pharmaceutical water, etc.
2The sterilization efficiency depends on the transparency, impurities, and temperature of the water body, with the lowest being99.9%Or specially designed.
3Manual or automatic cleaning devices can be configured according to customer needs.
UV sterilizer (UV sterilizer)The best usage conditions
(1)Water temperature:5℃~60℃Environmental temperature for use:-5℃~50℃Relative humidity around: not greater than93%(Temperature)25℃When)
(2)Voltage: AC220V±10V,50Hz.
(3)Drinking water: The water quality entering the treatment equipment1cmThe transmittance of(T254):95%~100%When the original water quality is lower than the national drinking water standard (e.g. chromaticity is higher than)15The degree and turbidity are higher than5The degree and iron content are higher than0.3milligram/First, use other purification and filtration methods to ensure that the purification meets the standard, and then use ultraviolet radiationCPurification of water treatment equipment.
(4)Aquaculture water: Fresh water and seawater treated and filtered by sand filtration or other equipment.
(5)Wastewater: According to sterilization requirements, the water quality entering the treatment equipment is1cmThe transmittance of(T254):≥40%Other requirements must meet the national "Comprehensive Wastewater Discharge Standards"GB8978-1996The second level standard in.
UV sterilizer (UV sterilizer)Maintenance and upkeep of equipment
(1)Regularly check to ensure the normal operation of the UV lamp.
(2)UV sterilizer (UV sterilizer)Continuous use9000After an hour or a year, the ultraviolet lamp should be replaced to ensure a high sterilization rate. Please pay special attention to keeping the ultraviolet light on continuously, as repeated turning on and off can seriously affect the service life of the lamp.
(3)When replacing the ultraviolet lamp, first unplug the lamp power socket and take out the ultraviolet lamp. When replacing the new lamp tube, be careful not to touch the quartz glass of the new lamp tube with your fingers, as stains can affect the sterilization light. At the same time, carefully place the lamp tube into the stainless steel sterilizer.
(4)If there is hardness in the water(Calcium or magnesium)If the substance is iron or manganese, then the quartz tube needs to be cleaned regularly. After cleaning the quartz tube, special plastic gloves should be worn to carefully install the quartz tube into the reactor. After installing the sealing ring, check for any water leakage, plug in the power supply, and ensure that the detection lamp emits stable light.
Note: Ultraviolet radiation has a strong killing effect on bacteria and can also cause certain harm to the human body. The most vulnerable part of the human body is the eyes, so it is not advisable to look directly at lit lamps at any time to avoid injury.
7UV sterilizer (UV sterilizer)Precautions for equipment installation
1The ultraviolet sterilization device should be placed in a place that is easy to clean and inspect.
2For the convenience of replacing accessories and installing ultraviolet sterilization devices, there should be a certain amount of space on both sides of the device, depending on the specific model.
3Do not allow equipment to freeze.
4It is recommended to use an environment with a temperature not exceeding60℃.
5In use200V/50HzWhen using a power source other than the one provided, please consult the seller first.
6、UV sterilizer (UV sterilizer)The biggest work pressure is1.2mpa
Compared with disinfection equipment produced by other manufacturers, our company's ultraviolet sterilizer (UV sterilizer) has sealed heads on both sides, no dead corners of water flow, no residue, and thorough disinfection. The outer shell of the pipe wall is2.5mm204Made of genuine stainless steel, capable of withstanding pressure up to16Kilogram, sturdy and durable, the lamp tube is imported from the United States and has a service life of Lysos12000Over an hour, thoroughly sterilized, widely used for disinfection of secondary water supply, drinking water, purified water, mineral water, and swimming pool water. And can be made according to customer requirements, including frame type UV sterilizers (UV sterilizers), automatic cleaning UV sterilizers (UV sterilizers), manual cleaning UV sterilizers (UV sterilizers), open channel type UV sterilizers (UV sterilizers), upper and lower type UV sterilizers (UV sterilizers), large split type UV sterilizers (UV sterilizers), etc
Online inquiry