The performance characteristics of the 12Z type non-magnetic metal conductivity meter from Germany's Yabai eddy current conductivity meter are as follows:
12ZUsed to measure the conductivity of non-magnetic metals
main features:
lHandheld design
lThe calibration standard is an internationally traceable standard(Boeing)
ldirect%IACSreading
lNon contact measurement with lift off compensation
lautomatic temperature compensation
l 4×AABattery, providing approximately100Hour by hour operation
leasy to operate
Technical parameters of the 12Z type non-magnetic metal conductivity meter from Germany's Yabai eddy current conductivity meter:
Measurement range:1.5 - 110% IACS
Min interface: diameter10mm(standard)perhaps7.5mm(optional)
resolution: 0.1% IACS (65 - 110% IACS)
0.05% IACS (30 - 65% IACS)
0.02% IACS (10 - 30% IACS)
0.01% IACS (1.5 -10% IACS)
Measurement accuracy at ambient temperature: 10 - 30℃,±1%;0 - 40℃, in2%
Withdrawal compensation:up to200μm
frequency: 60 khz
power supply: 4×AAalkaline battery
operate temperature: 0 - 40℃
Advantages of the 12Z type non-magnetic metal conductivity meter from Germany's Yabai eddy current conductivity meter:
1Turn on the deviceimmediatelyuse
Like inputting parameters such as thermal drift, other devices require preheating and2Point or3Point calibration.
2.Single point calibration, automatic temperature compensation
In one operation, the instrument will display that it has been compensated for20The conductivity at ℃ is based on the standard of conductivity approaching the target material. This simplifies and accelerates the measurement process. This method also ensures accurate readings regardless of who the operator is.
3.Synchronized lift off readings
The model shows approximateμmThe lift off reading of the unit can be used to estimate the thickness of the coating.
4.Easy to use
Among all the instruments on the market,12ZIt is easy to use and less prone to operator errors.12ZThe training only takes a few minutes, saving employees' time. Since the instrument is calibrated with its own sensors, it is impossible for errors to occur due to the complex installation process of the new probe. If a probe needs to be installed, before returning to the customerZAPPITECDuring installation, we will ensure that the instrument readings are accurate in metric blue.
5Extremely long battery life
12ZUsing ordinaryAAAlkaline batteries are easy to replace. This allows the instrument to operate without interruption, without the need for charging, and maintain maneuverability without the need for a power outlet.
lMeasurement of Electrical Conductivity of Non ferromagnetic Metals
lComposition, Heat Treatment, Evaluation, and Sorting of Non Destructive Alloys
lHeat treatment evaluation of copper chromium, copper zirconium and aluminum alloys
lThermal damage determination of aluminum alloys for aerospace industry
lRaw material purity(Copper, silver, gold, aluminum)Quality control. Optional7.5mmsensor measurement8mmCopper rod cross-section
lApproximate analysis of some binary alloys
Measurement of Thermal Conductivity of Metals