GermanyWTWFDO700IQFluorescence based dissolved oxygen sensorUnfilled electrolyte;GermanyWTWFDO700IQFluorescence based dissolved oxygen sensorAdopting intelligent thin film correction(IQMC)Technology, no need for calibration;GermanyWTWFDO700IQFluorescence based dissolved oxygen sensorGreen light technology(GLT)The fluorescent cap has a long lifespan.
GermanyWTWFDO700IQFluorescence based dissolved oxygen sensorWorking Principle:
A layer of fluorescent dye is covered on the thin film at the top of the sensor. When a short wavelength light is irradiated onto the fluorescent dye, it emits long wavelength red light when it returns from the excited state to the ground state. The red light is the test signal. The higher the concentration of dissolved oxygen, the shorter the duration of red light. By testing the duration of red light, the concentration of dissolved oxygen can be determined. The fluorescent dissolved oxygen sensor of the first generation has the following drawbacks:
1. The longer the film is in contact with water, the greater the signal drift
2. Fluorescent dyes are prone to aging after exposure to blue light
3. Sensors are more sensitive to bubbles
WTWby virtue of60Years of manufacturing experience have successfully overcome the above difficulties and launched the second-generation fluorescence based dissolved oxygen sensor. The technological advantages of the second-generation sensors are mainly reflected in the following aspects:
· IQMCtechnology:Each diaphragm undergoes strict calibration before leaving the factory, and the calibration data is stored in the chip on the diaphragm.
· EPRSEqual optical path reference system:The test optical path and reference optical path, as well as the complete symmetry of the optical path system, can synchronously eliminate the influence of optical component aging. Ensure high testing accuracy within the lifespan of the sensor.
· GLTGreen light technology:Green light has relatively less energy compared to blue light, which can avoid the fading effect of fluorescent dyes and extend the service life of the film, usually achieving2Years of lifespan.
· 45Degree testing technology:The top of the sensor does not adopt a flat structure, but has a45The slope of the degree can avoid the accumulation of bubbles, thus solving the problem of the first generation being easily disturbed by bubbles.
· C2Light speed correction calibration:The fluorescence method ultimately boils down to the issue of testing time, thereforeWTWThe time testing system is strictly calibrated according to the physical constant of light speed, ensuring accurate time testing.
WTWHaving the above technological advantages, thereforeFDOFluorescence based dissolved oxygen sensors do not require calibration during use, and have high measurement accuracy and stability, bringing great convenience.
GermanyWTWFDO700IQLumineOptical dissolved oxygen transfersensorFeatures:
· Two year warranty
· Adopting intelligent thin film correction(IQMC)Technology, no need for calibration
· C2Light speed correction, high measurement accuracy
· Green light technology(GLT)The fluorescent cap has a long lifespan
· Equal optical path reference systemEPRSStable measurement without drift
· 45Degree design, not affected by bubbles
· Unfilled electrolyte
· No requirement for very low flow rate
GermanywtwFDO700IQFluorescence based dissolved oxygen sensorTechnical Specifications:
|
test method |
Green light fluorescence method |
|
Range (25 ℃) |
O2Concentration: 0... 20.00 mg/l |
|
resolution |
O2Concentration: 0.01 mg/l |
|
measurement accuracy |
When<1mg/l, it is+/-='' 0.05='' mg/l=''> |
|
Repeatability |
+/- 0.05 mg/l |
|
Reaction time at 25 ℃ |
t90<150>150> |
|
Very low flow rate |
No requirements |
|
Electric inspection is very important |
Thin film monitoring function |
|
signal output |
digital signal |
|
Correction |
No need |
|
Power consumption |
0.7 watts |
|
Temperature test |
-5 ℃...+60 ℃, built-in NTC probe |
|
temperature compensation |
-5℃…+50℃ |
|
Voltage resistance |
10 bar (including sensor cable) |
|
surrounding environment |
Work: -5 ℃...+50 ℃) |
|
Connector |
2-core shielded wire, IQ specific connector |
|
input power |
IQ Sensor Net power supply |
|
Lightning protection circuit |
have |
|
EMI/RFI protection |
EN 61326, Class B, FCC Class A, |
|
Certification |
CE, cETLus |
|
Construction |
Film head: POM, PVC, silicone |
|
Size |
400X40 mm SW: 400X59.5 mm |
|
Weight |
About 900g SW, about 1500g |
Ordering Guide
|
Dissolved oxygen sensor |
Order Number |
|
|
FDO® 700 IQ |
Fluorescence dissolved oxygen sensor, sewage detection |
201650 |
|
FDO® 700 IQ SW |
Fluorescence dissolved oxygen sensor, seawater detection |
201652 |
|
SACIQ-7.0 |
IQ sensor dedicated cable, 7 meters long |
480042 |