German Spike Direct Reading Spectro MAXx BT

Manufacturer Introduction
Spike Analytical Instruments, a German company, is currently the world's largest manufacturer of atomic emission spectrometers. Since its establishment in 1979, it has not only inherited the tradition of high-quality optical instrument manufacturing in Germany, but also maintained a leading position in the world of emission spectroscopy technology with its unique advanced technology, stable and reliable quality, and thoughtful after-sales service. At present, tens of thousands of various spectrometers have been provided to users around the world, and nearly 5000 SPECTRO direct reading spectrometers are in operation and use in China. There are 800 users using it in Guangdong Province.
Spike's products are widely used in various fields such as steel metallurgy, non-ferrous metals, petrochemicals, machinery manufacturing, energy and power, railway transportation, aerospace, food hygiene, environmental protection, and teaching and research.
The main products of Spike Company in Germany include:
Spark direct reading spectrometer series - SPECTRLAB/MAXx

Headquartered in Krevo, Germany (Boschstrasse 10)

• 3740 sq. Meters (40225 sq. ft.)
• Management Department
Research and Development Center
• Sales and after-sales service
• Finance

Since its establishment in 2005, Yide Instrument has always adhered to the concept of "quality, professionalism, and responsibility" and won the trust of customers with honest business practices. For the past 8 years, it has been the official authorized dealer of German Spike Analytical Instruments Company, specializing in the operation of German Spike direct reading spectrometers, providing users with world-class German quality spectral instruments and equipment, and customizing laboratory solutions for customers. Through professional, meticulous, and comprehensive technical support services, it realizes its commitment to "creating more value for customers". Our products cover various fields such as steel metallurgy, non-ferrous metals, petrochemicals, machinery manufacturing, metal recycling, energy and electricity, railway transportation, aerospace, food hygiene, environmental protection, and teaching and research.
At this point, we will continue to provide you with advanced and reliable instruments and thoughtful and timely professional services, becoming your good helper and partner in the field of analysis.
The Technical Attachments
of SPECTROMAXx
Technical documents
Part 1: Scope of Supply
A. The Scope of Supply of The Contract
Standard accessory
Standard Accessories MAXx (LMX06)
Standard Attachment Package
Standard Accessories (Revision 3)
Quantity |
Unit |
Description |
Part No. |
1 |
ea |
CONSUMABLES SPECTROMAXx (LMX06) STANDARD Standard Consumables Package |
|
1 |
ea |
User Manual for User MANUAL SPECTROMAXX (LMX06) |
|
1 |
ea |
CABLE POWER 1,8M BLACK GERMAN-SCHUCKO power cord |
|
1 |
ea |
TUBE CU with ARGON CONNECTION Argon Copper Tube |
|
Standard consumables package
Standard Consumables (Revision 1)
Quantity |
Unit |
Description |
Part No. |
1 |
ea |
DOCUMENT BAG 400 * 300 * 80MM BLACK file package |
|
1 |
ea |
WRENCH, ALLEN, 2MM WITH HANDLE LONG electrode wrench |
|
1 |
ea |
SCREWDRIVE RECESSED HEAD SCREWS/SIZE 2 Phillips screwdriver |
|
1 |
ea |
SPARE PART KIT O-RINGS FOR SPARK STAND O-Ring Spare Parts Set |
|
1 |
ea |
INSULING BODY ELECTRIC HOLDER Insulator |
|
5 |
ea |
Spring Pressure C=0113 N/MM L0=51.3 MM electrode spring |
|
10 |
ea |
SET SCREW HEX SOCKET M4*4/ST/ZINCED
Electrode top wire
|
|
3 |
ea |
WINDOW QUARTZ D=11/T=1.25 Airlight Chamber Stone Window |
|
10 |
ea |
DISK, D11 * 0,5 PTFE/NYLON nylon gasket |
|
2 |
ea |
HOSE CLIP AD=12-20MM Throat Clamp |
|
1 |
ea |
Filter MAT 265MM * 220MM filter screen |
|
1 |
ea |
Filter MAT F360 90MM * 70MM filter screen |
|
1 |
ea |
HOUSING TOOL FOR WINDOW SUPPORT D14 * 60 Disassembly quartz window special tool |
|
5 |
ea |
BRUSH STEEL WIRE L=100MM/D=5MM electrode brush |
|
3 |
ea |
ELECTRODE TUNGSTEN D6.15 * 56 Dual 90 ° Tungsten Electrode |
|
1 |
ea |
CABLE RJ45 "CROSSOVER" 3M CAT. 5 Ethernet cable |
|
1 |
ea |
SOCKET FIVE-FOLD 16A/250V with SWITCH European socket |
|
1 |
ea |
Poster PERIODIC TABLE 700 * 1000MM periodic table wall painting |
|
Part 2: Analysis Program
B. Analytical Program
The instrument is calibrated with limited international standard which Spectro Analytical Instruments GmbH have for general purpose. For special alloy and special elements, the instrument must be calibrated by customer themselves.
The following working curve was plotted by Spike Analytical Instruments in Germany using international standard samples (with a channel linear range greater than the range of the following working curve). For special alloys, elements, and analysis ranges proposed by users, standard samples will be provided by users and drawn free of charge by Spike Company.
element |
Carbon steel and medium low alloy steel |
|
Fe-10 |
|
% |
C |
0.0015--1.45 |
Si |
0.001--4 |
Mn |
0.0005--2.3 |
P |
0.0005--0.13 |
S |
0.0005--0.12 |
Cr |
0.001--7 |
Mo |
0.0015--4 |
Ni |
0.0015--5.5 |
Al |
0.001--2 |
Cu |
0.0005--1.2 |
Ti |
0.0007--0.82 |
V |
0.0005--1.1 |
Fe |
Remaining balance |
Part Three: Instrument Technical Configuration
C. Description
The SPECTROMAXx consists of the following components:
The SPECTROMAXX direct reading spectrometer consists of the following parts:
Optic
optical system
Spark stand
Spark stand
Spark source
spark light source
Spectrometer control
Spectrometer control system
Readout system
Data readout system
Spark Analyzer Pro Max Software
Spark Analyzer Pro analysis software
DESCRIPTION OF THE COMPONENTS
Description of each component
Optic optical system
High resolution Multi detectors
Multiple high-resolution detectors
Stabilized against fluctuations in temperature
Stable structure resistant to temperature fluctuations
Drift free due to the material used
Using materials that do not produce drift
Automated profiling
Automatic tracing
Analysis Modules Analysis Mode
Freely selectable analytical modules
Flexible choice of analysis mode
Optimized to customer requirements
Optimize according to specific user analysis requirements
Easily, on site addition of additional modules
Convenient to add analysis modes on-site for users
Spark Stand
Open spark stand for high sample throughput
Open spark table, fast sample switching
Analysis of samples with various kinds of geometrics
Suitable for analyzing samples of various geometric shapes
Optimized Argon flow
Optimization of argon gas flow
Minimized Argon consumption ( Argon Saver Module)
Minimum argon consumption design (argon saving mode)
Reduced cleaning intervals
Reduce cleaning frequency
Table plate easily exchangeable
Easy to replace spark table
Temperature absorbent design, water cooling not required
Design of heat absorption device, no need for water cooling
Integrated shutter system for optimum plasma viewing
Integrated shutter system for optimal plasma observation angle switching
Activate the system
Excitation System
Fully digital plasma generator. Digital discharge parameter setting, digital pulse generator, digital offline pulse control.
Fully digitalized plasma generator with digital discharge definition, digital pulse generation and digital offline pulse control
32 MHz microprocessor control
32 MHz micro-controller
Data readout rate: 200 microseconds with 400 discharges
Sampling rate: 400 in 200s-discharge
Energy resolution: 125 milliwatts
Energy resolution: 125 mW
Maximum single spark discharge time: 4000 microseconds
Max. spark duration: 4000s
Maximum spark power: 4 kW
Max. spark power 4 KW
Readout system
High Speed 12 Bit ADC
High speed 12 bit AD conversion
DSP-Controller with 66 MHz
66 MHz DSP controller
Serial Source-Interface
The light source is equipped with a serial interface
Spectrometer PC Control Computer System for Spectrometer Control
External computer system
External control computer system
Operating system Windows ™
Windows ™ operating system
Keyboard and mouse
Keyboard and mouse
TFT LCD Display
LCD display screen
Printer
printer
SparkAnalyzer Vision Mx Software (64 bit) analysis software
General Overall Function
ICAL – Intelligent Calibration Logic (only one sample for standardization)
ICAO Intelligent Logic Calibration (Standardization only requires one standard sample)
Visualized diagnostic system for maintenance request and real time System diagnostic
Hardware status diagnosis real-time display system, maintenance plan design and prompts
Software controlled Argon-Saver-Module
Software controlled argon gas saving mode
User friendly system surface under windows
Windows Environment User Friendly Interface
Function keys for routine operation
Daily operation function key control
Configuration of different User Levels
Parameter settings for different user levels
Multiple language support (pre-configured languages are GER, ENG)
Multi language support (default English, German)
Result Manager
Result Manager Data Management Software
Calibration Software
Curve fit up to cubic equation
Cubic equation regression curve
Calculation of spectral interferences and interelement corrections
Automatic or manual correction of spectral lines and coexisting elements
Graphic display of calibration curves with zoom function and calculated correction factors
The image display of the correction curve can be simplified and the correction coefficient can be calculated
Identification of calibration standards by alloy-group
Group correction standard samples for alloy categories
Standards library
Standard sample library
Measurement measurement
Calculation of concentration proportions using calibration polynome
Using polynomial correction method to calculate concentration ratio
Automatic switch over of spectral lines according to their concentration ranges
Automatically select analysis spectral lines based on the concentration of elements
Matrix correction
Matrix correction
Material (quality) specific Type recalibration
Material (brand) type recalibration
Automatic program selection (APF)
Automatic analysis program switching
Dynamic Pre-Spark Mode
Dynamic pre ignition time setting mode
Flagging of results beyond calibration range
Mark analysis results that exceed the concentration range of the working curve
Input and calculation of user defined formulas
Enter and calculate according to user-defined formulas
Input of user-defined sample identity codes
User defined sample identification code input
Free editable quality data base
Flexible editing of databases
Quality check function
Brand verification function
Quality identification function
Brand identification function
Output data output
Output of results in various concentrations and intensity mode
The analysis results are displayed in multiple modes, including concentration and intensity
Concentration unit selectable (%, ppm)
%, Ppm concentration display unit optional
Output of statistical data (e.g. average of up to 50 single sparks, rel. standard deviation)
Statistical result output (calculation of the average and relative standard deviation of up to 50 excitation results)
Average calculation manual set with the possibility to switch back to single sparks
Calculation of manual average value, and can return to the results of a single spark analysis
Common output for gliding average and single sparks on screen
Screen display of average value and single spark value
Fonts, font-size, count of single sparks, etc. are freely configurable
Display font, font size, single spark count, etc. can be flexibly set
Automatic and/or user controlled printout of analytical results and statistical data
Printed output of automatic or manual analysis and statistical results
Automatic and/or user controlled storage of analytical results and statistical data
Storage of automatic or manual analysis and statistical results
Transmission of results to remote printers and/or terminals
Transmission of results from remote printers and/or terminals
Transmission of results via TCP/IP
Data transmission through TCP/IP protocol
Electrical Requirements: Power Supply
230 V + 10 % / - 10 %, 50 Hz
max. 400VA during spark mode
During excitation, the maximum is 400VA
16 A slow-blow fuse
16A slow melting fuse
Temperature range
+10°C - +30°C
Air humidity range humidity
20 – 80%
Argon inlet pressure
7 bar
Argon quality (min.)
5.0 (99.999% Ar)
Argon flow rates
Constant flow rate of 29 l/h
Analytical flow 209 l/h
Part Four: After sales Service and Others
D. Service and Miscellanea
1. Installation, debugging, training, and equipment handover Commissioning
The total contract price includes installation and commissioning, instrument operation training, and equipment handover to the user. The total working time for installation, debugging, training, and acceptance at the user's site shall not exceed 3 days. Extra work requires additional charges. The handover of equipment shall be terminated by equipment acceptance. The perfect operation of the acceptance display analysis system, instrument performance and supply scope meet the contract description, and the acceptance report is signed by representatives of both parties. Before installation, the buyer must prepare the installation conditions according to the installation requirements provided by the seller. If the acceptance is not completed due to the buyer's reasons, additional fees will be charged for re acceptance.
The total price includes installation, commissioning of the analytical instrument and a basic training of its operation. The on-site installation and commissioning time of the system is limited to max. 3 days. Additional requirements such as (but not limited to) analytical help, training etc. will be invoiced. The commissioning is completed with an acceptance test, which shall demonstrate the perfect operation of the analytical instruments. Upon fulfilment of the Spectro specifications of the quoted analytical instrument, the acceptance protocol has to be issued and signed by both parties. Prior to commissioning, the laboratory and all necessary facilities for the commissioning of quoted analytical instruments must be fulfilled by the purchaser/end user according to the installation requirements which provided by Seller. Any reason caused by purchaser/end user to lead the failing of commissioning, the re-commissioning will be invoiced.
2. Warranty period
The warranty period is 12 months after acceptance or 18 months from the date of the German invoice, whichever comes first. Except for damages caused by improper use by the user, during the warranty period, Spike Analytical Instruments in Germany is responsible for free repair or replacement of the corresponding damaged parts for the user.
The warranty period is 12 months after acceptance or 18 month from invoice date, whatever occurs first. All faulty components will be repaired or replaced free of charge, except for damages caused by customer's negligence.
The supplier is responsible for lifelong maintenance. Outside the warranty period, the supplier shall continue to provide high-quality services to the user.
The Seller should always provide the buyer with good service after warranty.
The supplier has a bonded spare parts warehouse to ensure the supply of spare parts.
The Seller must supply the spare parts to the buyer in time.
3. Acceptance
Use recalibration standards for technical acceptance.
The international standard samples will be selected during acceptance.
Conduct inventory and acceptance according to the supply scope specified in the contract.
The quantity will be checked according to the supply scope of the contract.
4. Customs Tariff No
According to the Brussels Customs Treaty, the customs identification number for the instrument is 90.27.30.00
For this type of instrument Customs Tariff No. 90.27.30.00 has to be applied according to the Brussels Customs Tariff Scheme.
5. Country of origin of the equipment
Unless otherwise specified, this quotation covers all supply scope originating from the Federal Republic of Germany.
Except where otherwise stated, country of origin of the items quoted in this offer is the Federal Republic of Germany.