Two laser beams with the same frequency and phase emitted from the light source intersect in the testing area, and two similar light intensity signals with fluctuations are obtained on two detectors. The part with the same fluctuation of the two light intensity signals is the actual light intensity signal of the particles, while the part with different fluctuations is the interference signal, which is filtered out. The photomultiplier tube sends the same real particle signal to the correlator for processing, and the correlator sends the processing results to the computer to obtain the final test report.
parameter |
Indicator |
measuring principle |
Photon Cross Correlation Spectroscopy (PCCS) |
Scope of testing |
0.5-10000nm, measurable suspension, emulsion, microemulsion and other systems |
data processing |
By using different calculation methods, detailed data on the average particle size and particle size distribution of nanoparticles can be provided |
concentration range |
ppm -70 vol.%*, And it can directly measure fluorescent substances and colored substances |
light source |
Semiconductor laser, wavelength 658nm, stable light source |
laser power |
30mw, laser power can be adjusted and controlled through software |
Product laser grade |
class a |
measuring technique |
Dual laser beams, dual detectors, TCP/IP transmission |
Correlators |
Multi channel correlator, minimum sampling time ≤ 30ns |
Temperature control system |
Peltier temperature control system, optimal testing range: 0-90 ℃, temperature automatically controlled through software Temperature stability: ≤ 0.1℃ |
Sample pool volume |
Trace amount: 50-2000 μ l; Constant: 4ml Max |
Testing time |
2-5 minutes, during the testing process, the monitor dynamically monitors the fluctuation of light intensity and particle size in real-time |
detector |
Photomultiplier tube (PMT) detector, with strong linear characteristics, does not require calibration |
Control and operation software |
Suitable for Windows system: Complete set of instrument operation and maintenance manuals One set of software operation manual in both Chinese and English Original CD of instrument software System recovery CD, instrument configuration list CD |
Power Supply |
AC65-260V, 50/60Hz |
Environmental requirements |
Temperature: 15-40 ℃, humidity 20-70%, no condensation |
Adopting the new Photon Cross Correlation Spectroscopy (PCCS) principle;
Dual beams and dual detectors work simultaneously, selecting only the single scattering signal generated by the particles, removing interference signals, and reducing environmental requirements;
Completely solve the problem of inevitable multiple scattering in high concentration liquids;
Can directly measure fluorescent substances and colored substances;
The testing time is 2-5 minutes, and real-time dynamic monitoring of light intensity fluctuations and particle size is carried out during the testing process;
Automatically adjust the position of the sample pool through computer software to obtain the most accurate measurement results;
According to the size of the measured particles, the output power of the laser source can be automatically adjusted by the computer;