ELTRA's CHS-580 is an ideal carbon, hydrogen, and sulfur analyzer for simultaneous determination of organic samples.
Even samples up to 500mg or more, and even non-uniform materials, can be reliably analyzed. The temperature of the horizontal resistance furnace and ceramic tube can reach 1550 ℃, which is adjustable at 1 ℃. The analyzer can be equipped with three independent infrared detection cells according to user requirements, which are suitable for most organic samples.
ELTRA's CHS-580A is an ideal carbon, hydrogen, and sulfur analyzer for simultaneous determination of organic samples.
ELTRA's CHS-580A analyzer (A=automatic loader) is equipped with an automatic sampler that can analyze large amounts of samples without the need for an operator. The sampler has 36 crucibles and 130 crucibles.
The CHS-580A series is a vertical resistance furnace and ceramic tube technology based on the CHS-580 analyzer, with a heating temperature of * * 1550 ℃ and an adjustable temperature of 1 ℃. Samples weighing up to 500mg and even uneven materials can be reliably analyzed. This analyzer can be assembled according to user requirements to meet various applications.
Application Examples
oil, soot, Waste, plant materials, rubber, tobacco, coke, coal ..
advantage
Capable of simultaneously measuring carbon, hydrogen, and sulfur in small samples
Elemental analysis for organic samples
Fast, accurate, and reliable analysis
The combustion temperature of the horizontal resistance furnace is 1550 ℃, adjustable at 1 ℃
Customizable measurement range
Using a gold-plated detection cell can effectively prevent corrosion of the detection cell when analyzing samples containing halogens or acids.
Powerful software features (multilingual, customizable display, output results)
Single point and multi-point calibration
No maintenance required
Sturdy construction, suitable for laboratory and production control
performance metrics

Principle of action
CHS-580 is easy to operate
After weighing the sample, it is placed in a ceramic sample boat, and the weight value is transmitted to the computer (or manually entered). Then, the sample boat is placed in a resistance furnace for combustion, with an average analysis time of 60 to 180 seconds. The detector signal and instrument parameters can be displayed during the analysis process.
*The evaluation of the post signal and the display of the analysis results will be automatically completed, and the data can be transmitted to the Laboratory Information Management System (LIMS).
CHS-580A operation
CHS-580A involves loading the sample into a crucible and then using a pair of pliers to place the sample onto the base of an automatic loader, allowing the sample to continuously burn in the furnace. The average analysis time is 60 to 180 seconds, and both detector signals and instrument parameters can be displayed during the analysis process. *The evaluation of the post signal and the display of the analysis results will be automatically completed; The data can be transmitted to the Laboratory Information Management System (LIMS). This series only requires maintenance for dust removal and filtration devices and chemicals, and is very easy to operate and complete.
Measurement principle of CHS-580
The CHS-580 sample is burned in an oxygen atmosphere at temperatures up to 1550 ℃. The temperature inside the furnace can be freely selected to gradually increase or decrease by 1 ℃. The combustion gases (carbon dioxide, water, sulfur dioxide) from the furnace first pass through a particulate filter and then enter the heated H2O
Infrared pool. Afterwards, it is a dry gas that chemically absorbs water vapor, carbon dioxide, and sulfur dioxide. Three infrared pools can be configured as needed.