Product Introduction
summary:
- Interchangeable 'smart' sensors
- Data recording time exceeds one year
- Standard short-term exposure level (S) and time weighted average (TWA)
- Compatible with Docking Station
The GasBadge Pro is designed with high quality and reliability standards from Innovent, providing protection against hazardous gases. The interchangeable 'smart' sensors enable GasBadge?Pro can quickly adapt to oxygen or the following toxic gases recognized by the monitor as non safe levels: carbon monoxide, hydrogen sulfide, nitrogen dioxide, sulfur dioxide, phosphine, ammonia, hydrogen cyanide, and hydrogen.
GasBadge Pro communicates directly with optional accessories such as Docking Station through an infrared interface Datalink and infrared printer continue to simplify and automate the calibration process, functional (impact) testing, and data downloading. The standard short-term exposure level (S), time weighted average (TWA), and up to one year of survey data recording function, as well as an event recorder capable of recording 15 alarm events.
This product is equipped with a shockproof shell, which is not affected by radio frequency interference, and has the characteristics of waterproofing and durability. The shockproof protective layer protects the product from damage caused by harsh working environments. Its easy-to-use and sensitive four key navigation allows for easy installation, setup, operation, and calibration functions.
Technical parameters:
Shell: |
Durable and sturdy, with a waterproof polycarbonate shell and protective rubber filling. Prevent radio frequency interference. |
||||||||||||||||||||||||||||||||||||||||||||||||
Size: | 3.2 x 1.9 x 1.1 inches (81.3 mm x 48.3 mm x 27.9 mm) |
||||||||||||||||||||||||||||||||||||||||||||||||
Weight: |
3 oz. (85 grams) |
||||||||||||||||||||||||||||||||||||||||||||||||
Range: |
|
||||||||||||||||||||||||||||||||||||||||||||||||
Display screen: |
Customized LCD display with icon display, simple and easy to use. |
||||||||||||||||||||||||||||||||||||||||||||||||
Alarm: |
User selectable low/high alarm device. |
||||||||||||||||||||||||||||||||||||||||||||||||
Battery (running time): |
User replaceable 3V, CR2 lithium battery Under normal circumstances, the running time can reach over 2600 hours |
||||||||||||||||||||||||||||||||||||||||||||||||
Event record: |
Continuously running. Record 15 alarm events, including their occurrence time, duration, and visible gas leakage concentration during the event. Event records can be viewed on a computer or directly transmitted from the instrument to an infrared printer for printing. |
||||||||||||||||||||||||||||||||||||||||||||||||
Data recording: |
One year, with an interval of one minute | ||||||||||||||||||||||||||||||||||||||||||||||||
Temperature range: |
Normally: -40? Up to 60? C (-40 to 140? F) | ||||||||||||||||||||||||||||||||||||||||||||||||
Humidity range: |
Normally: 0-99% RH (non condensing) | ||||||||||||||||||||||||||||||||||||||||||||||||
|
performance |
advantage |
Running time |
Continuous operation for over 2600 hours, power supply: replaceable CR2 lithium battery.
|
|
|
display |
Users can configure the display screen to display real-time readings directly (in ppm or% content) (O2)Or only display the gas type.
|
|
|
Display Size |
The direct gas reading display screen is the larger and more visible display screen used in single gas detection instruments. Icons make the user interface simple and refreshing.
|
|
|
Time weighted average (TWA) and short-term exposure limit (S) |
The current viewing function for TWA and S values is GasBadge?Pro standard configuration.
|
|
|
TWA and S alarms can be adjusted by users themselves. |
The time weighted average (TWA) and short-term exposure limit (S) alarms can be adjusted by the user to ensure that the device will enter an alarm state when the customized set point is exceeded, prompting the user of the alarm situation that has occurred.
|
|
|
data record |
Standard one-year data recording energy.
|
|
|
Adjustable data recording interval |
The adjustable recording interval allows users to choose the frequency at which the instrument records information.
|
|
|
GasBadge? data connection |
The GasBadge data link is an optional accessory that enables instant download of alarm events, instrument details, and hygiene data to a computer (via USB connection).
|
|
|
Compatible with DS2 Docking Station? |
The DS2 Docking Station is a GasBadge?Optional accessories for Pro. The Instrument Docking Station (IDS) provides automatic instrument calibration, data maintenance, diagnosis, and data download functions. Utilize a central database to store information for archiving or printing purposes. Can link up to 100 IDS modules - can connect thousands of instruments.
|
|
|
Display screen backlight |
Users only need to press the button to view the current gas reading in low light environments. When an alarm condition occurs, the backlight will flash to alert.
|
|
|
Four key operation |
Users can easily configure the instrument. GasBadge Pro provides convenient user selection for single gas detection instruments.
|
|
|
Sensor options |
Interchangeable "smart" sensors can monitor oxygen or any of the following toxic gases: CO, H2S, O2, NO2, SO2, Cl2, ClO2, PH3, NH3, H2, CO/H2 (zero), etc.
|
|
|
waterproof |
GasBadge?Pro has waterproof function, ensuring that the device can be protected from outdoor environmental conditions, such as rain, water mist formed during flushing, and other harsh industry applications.
|
|
|
Event record |
GasBadge?Pro will continuously record 15 alarm events. When the event recorder is full, it will automatically overwrite old records with a write.
|
|
|
Infrared printing interface |
The infrared interface allows the device to easily print event records to POS printers with infrared ports.
|
|
|
The alarm can be adjusted by the user themselves |
The setting points for low-level and high-level alarms can be adjusted by users themselves. This enables users to set instrument alarm functions according to their own enterprise standards.
|
|
|
Top plug-in sensor |
Even when placed in a shirt pocket, it can provide continuous and uninterrupted protection.
|
|
|
Sensor over range protection function |
Ensure that the sensor is protected when exposed to high concentrations of gas. When an over range situation occurs, the instrument will prompt the user with "OR".
|
|
|
Powerful auditory alarm device with vibration and visual alarm functions (standard configuration). |
Standard high pitched (95 decibels) auditory alarm; Bright visual alarm display, easy to see; If there is a dangerous state, a vibration alarm will be triggered to alert the user.
|
|
|
Small size (3.7 x 2 x 1.1 inches) (94 mm x 50.8 mm x 27.9 mm) |
Compact structure, can be fastened to the body with fixtures, does not affect comfort; Or it can be placed in the front pocket of the shirt. Top plug sensors will not be obscured by pockets and affect performance.
|
|
|
Lightweight -3.0 ounces (85 grams) |
The device weighs 3.0 ounces (85 grams) and is comfortable to wear.
|
|
|
Anti vibration protective shell |
The protective rubber filling makes the equipment durable and easy to handle.
|
|
|
Peak detection |
This instrument can continuously detect while maintaining high gas readings (the gas that the sensor has been in contact with since the last peak clearance) visibility within the site.
|
|
|
Calibration indication |
The 'Last Calibration Time' function allows end users to view the number of days since the last calibration.
|
|
|
Lifespan indicator |
GasBadge?Pro can continuously monitor and display the remaining lifespan of the instrument until it becomes inoperable.
|
|
|
Card nail |
Each GasBadge set?Pro comes with a belt clip and spring clip (standard configuration). Other accessories such as handling boxes and fire ropes are also available for purchase.
|
|
|
Anti electromagnetic interference (EMI)/anti radio frequency interference (RFI) |
External radio frequency interference from mobile phones, handheld wireless devices, and other electronic devices will not cause false alarms.
|
|
|
Self testing |
The automatic self-test function ensures the correct operation of instruments, sensors, and circuits. Users can initiate auxiliary function testing to ensure the proper functioning of the alarm function.
|
|
|
End of Life Warning |
When the battery life is seven days left, the empty battery icon will emit a flashing alarm, indicating to the user that the device's life is about to end. When there are only four hours left in the lifespan, users will receive an urgent alarm prompt every 15 seconds and the empty battery icon will flash. Both types of alarms are advance notifications to users: please replace the device.
|
|
|
Continuous operational performance |
The 'normally on' performance allows end users to set the instrument to an on-site mode that cannot be turned off. In this way, the instrument can continue to operate until the battery is depleted.
|
|
|
Calibration overdue indication |