Suzhou Bangxin Electronic Technology Co., Ltd
Home>Products>Gas chromatography instrument Shimadzu GC-2010 (Jiangsu second-hand gas chromatography)
Gas chromatography instrument Shimadzu GC-2010 (Jiangsu second-hand gas chromatography)
The main features of the second-hand Shimadzu GC2010 gas chromatograph (Jiangsu second-hand gas chromatograph) are: 1. High sensitivity detector serie
Product details


Second hand Shimadzu GC2010 gas chromatograph (Jiangsu second-hand gas chromatograph)Main features:

1、 Suitable for trace analysis
2010 Plus High Sensitivity Detector Series
With the continuous strictness of various laws and regulations, the demand for high-sensitivity trace analysis is increasing. To meet this demand, Shimadzu's FPD, FID and other detectors have been thoroughly redesigned and processed to achieve superior sensitivity levels in the world, making them more suitable for trace analysis.
2、 Various functions to improve analysis efficiency
Rapid cooling of column temperature box, reverse blowing technology, carrier gas saving function, etc.
1. Rapid cooling of column temperature box
An independent cooling fan has been added and air circulation has been optimized, resulting in a significant increase in the cooling speed of the column temperature box (from 450 ° C to 50 ° C in just 3.4 minutes). The fan noise has also been reduced. When using the blowback function, the analysis time will be further reduced.
2. Advanced Flow Technology (AFT) series
The new flow control technology meets the requirements of high-throughput and high-efficiency analysis.
Backblowing system
Shorten analysis time
When the target compound is detected, the blowback system changes the flow direction of the carrier gas to blow out the remaining residual substances from the diversion flow path at the injection port end, shortening the analysis time and improving the analysis efficiency.
Detector diversion system
Improve qualitative accuracy and analysis efficiency
The detector splitting system splits the separated substances from the analytical column into different detectors to obtain various spectral information, thereby obtaining accurate qualitative information.
3. Rich self checking function to prevent instrument failures
By using the self check function, it can be confirmed whether the device is operating normally. Detailed inspection of temperature sensors, control conditions, gas supply pressure, etc. can be carried out to prevent accidental shutdown of the instrument.
4. The carrier gas saving function can reduce the consumption of carrier gas
This function reduces the amount of carrier gas discharged from the diversion outlet by adjusting the diversion ratio, truly achieving carrier gas savings and reducing analysis costs.
By using this function, the split flow rate can be reduced from 50mL/min to 5mL/min after injection, greatly saving analysis costs.
5. The hydrogen connection joint adopts reverse thread to avoid incorrect pipeline connection (* * design)
Reverse threading avoids hydrogen gas * * problems caused by incorrect pipeline connections.
The label indicates the direction of rotation of the switch, ensuring maximum usage.
6. Dual automatic sampling system
The combination of two AOC-20i automatic samplers and one AOC-20s automatic sampler forms a dual automatic sampling system. Simultaneous injection of two routes improves analysis efficiency and fully meets the requirements of NY/T 761-2008 Determination of Multiple Residues of Organophosphorus, Organochlorine, Pyrethroid and Carbamate Pesticides in Vegetables and Fruits.

Second hand Shimadzu GC2010 gas chromatograph (Jiangsu second-hand gas chromatograph)Technical parameters:

(Jiangsu Second hand Gas Chromatography) Second hand Shimadzu GC2010 Gas Chromatography Instrumentcolumn oven
temperature range

Room temperature+4 ℃~450 ℃ (when using liquid carbon dioxide * -50 ℃~450 ℃)

*Additional optional parts are required when using liquid carbon dioxide

size Length 280mm x Width 175mm x Height 280mm
internal volume 13.7L
Temperature accuracy Set value (K) ± 1% (can be calibrated at 0.01 ℃)
Temperature deviation Within 2 ℃ (on a circumference 30mm away from the inner wall and 200mm in diameter)
Correlation of room temperature changes <0.01℃/℃
Number of program segments 20 segments (cooling program available)
Program ratio setting range -250~250 ℃/min
Total program time ~9999.99 minutes
Cooling rate 450~50 ℃ for about 3.4 minutes

Second hand Shimadzu GC2010 gas chromatographSample injection unit

*Up to 3 injection units can be installed, each with independent temperature control (the number of units installed at the same time depends on the type of injection unit); Standard configuration includes split/no split injection unit

Split/Non Split Injection Unit (SPL-2010 Plus) Temperature Range: Room Temperature+5 ℃~450 ℃

Direct (full) injection unit (WBI-2010 Plus) temperature range: room temperature+5 ℃~450 ℃

Column loading/programmed temperature injection unit (OCI/PTV-2010) temperature range: room temperature+5 ℃~450 ℃;
Heating rate: within 3 minutes from 50 ℃ to 450 ℃; Cooling rate: 450 ℃~50 ℃ for 8 minutes (at column temperature of 50 ℃); Heating program: Heating rate of 250 ℃/min, capable of 7 stages of heating. The temperature rise and injection units for each program on the column can be switched (changes to OCI and PTV must replace the connection of the diversion piping)


Second hand Shimadzu GC2010 gas chromatographdetector
*Up to 4 detectors can be installed, with each unit having independent temperature control; The detector gas adopts APC electronic pressure control (the number of installations at the same time depends on the type of detector)
Temperature range of hydrogen flame ionization detector (FID):~450 ℃; Detection limit: 1.5 pgC/s (dodecane); Dynamic range: 107
Thermal conductivity detector (TCD) temperature range:~400 ℃; Sensitivity: 20000mV · mL/mg (decane)
Electron Capture Detector (ECD) temperature range:~400 ℃; Detection limit: 6fg/s (γ - BHC); Dynamic range: 104
Temperature range of flame photometric detector (FPD):~350 ℃; Detection limit: P 55fgP/s (tributyl phosphate), S 3pgS/s (dodecanethiol); Dynamic range: P 104,S 103
Temperature range of flame ionization detector (FTD, NPD, TSD):~450 ℃; Detection limit: N 0.1pgN/s (azobenzene), P 0.03pgP/s (malathion); Dynamic range: N,P 103
Second hand Shimadzu GC2010 gas chromatographFlow control unit
Advanced Flow Controller (AFC)
Pressure setting range for diversion/no diversion method: 0~970kPa; Number of program segments: 7 segments (available voltage reducing program); Program ratio setting range:- 400~400kPa/minute; Setting range of diversion ratio: 0~9999.9; Full flow setting range; 0~1200mL/min; During the heating process, the average linear velocity of the chromatographic column can be kept constant.

Direct (full volume) injection method, pressure mode, pressure setting range: 0~970kPa; Number of program segments: 7 segments; Program ratio setting range:- 400~400kPa/minute; Flow rate setting range: 0~1200mL/minute; Number of program segments: 7 segments; Program ratio setting range:- 400~400mL/min; During the heating process, the average linear velocity of the chromatographic column can be kept constant.

Second hand Shimadzu GC2010 gas chromatographdisplay
240 × 320 dot graphic display (30 columns × 16 rows)

Second hand Shimadzu GC2010 gas chromatographSize, weight, power supply (GC host)
size Length 515mm x Width 530mm x Height 440m
weight 30kg (FID type)
power supply AC230V±10%,2600VA,50/60Hz































Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!