Product Introduction
In the industrial production process, it is often necessary to monitor the production process at each stage and accurately analyze the raw materials, auxiliary materials, semi-finished products, and finished products. Currently, the production process is mostly manually sampled and analyzed, which is extremely complex and cannot reflect the real-time fluctuations of production in a timely manner. It is difficult to accurately reflect the timeliness and accuracy of measurement results. Our company has designed a continuous online titration analysis system, which can be installed near monitoring points and can analyze accurate results without the need for personnel to be on duty and control. Can solve the daily analysis and monitoring needs of industrial process control.Product Features
- The analysis system automatically completes tasks such as sampling, injection, analysis, cleaning, data calculation, and storage.
- It can achieve periodic monitoring, timed monitoring, etc.
- Unmanned operation can completely replace manual analysis.
- DCS can remotely monitor the operational status of equipment.
Technical Specifications
project
content
Main control device
10”High definition full-color touch screen display
redox titration
Potentiometric titration, polarization titration, photometric titration, and conductivity titration.
(*Each titration method must use a suitable detection device. )
Titration mode
Coordination titration, automatic inflection point detection, set point detection, setting/Automatic endpoint detection, intersection points(F,B,V1,V2)Detection, allocation method, petroleum product road value (oil)1/oil2)ThePHValue detectionPHValue automatic stabilizer, dissociation constant detection, calculation mode.
Burette capacity
20 mLtransparent glassburette(Standard) (Optional parts:1,5,10,50 mLburette)
Minimum volume of titrant
1.25 µL(20 mLburette)
Accuracy of burette
Accuracy: ±0.1%within
(20 mLThe cylinder body is completely discharged
Repeatability:0.01 mLWithin(20 mLThe cylinder body is completely discharged,n = 6Standard deviation of time
Testing Scope
pH:0 to14,resolution0.01pH
mV:-2000 to+2000 mV,resolution0.1 mV
Automatic input function
Automatically input blank titration values, factors, concentration detection results, etc
calculate
Concentration calculation, statistical calculationPHAutomatic value compensation
burette
Scalable to10Each titration workstation
external output
RS 485 Modbus RTUor4-20mA
electrode
GE-101BGlass composite electrode
RE-201REFERENCE ELECTRODE
(Different titration methods and electrode configurations)
power supply/power consumption
AC100–240V, 50/60 Hz, 220 VA
Explosion-proof rating
ExdeibmpzⅡCT4Gc
Overall dimensions
1800(H)×700(W)×600mm(D)
Application field
Suitable for fields such as chemical engineering, environmental protection, food, pharmaceuticals, papermaking, textiles, metallurgy, metal surface treatment, water quality treatment, etcAnalysis and monitoring of acidity, alkalinity, water hardness, chloride, cyanide, cyanuric acid, ammonia water, etc.