1、 Main features:
1. The GS-500 liquefied gas analyzer can be started and analyzed with one click, with a high degree of automation, reducing human error, good reliability, simple operation, and ensuring stable and reliable instrument quality,
It can operate continuously for a long time, ensuring work efficiency and saving maintenance costs. It automatically remembers operating parameters and does not require resetting when starting up.
2. The GS-500 liquefied gas analyzer is equipped with a gas cut-off protection system to prevent instrument damage caused by misoperation.
3. The gas path system of the GS-500 liquefied gas analyzer adopts a high-precision valve structure, which greatly improves the stability of the instrument's gas flow rate, thereby obtaining well reproducible analysis results.
4. The GS-500 liquefied gas analyzer can analyze nitrogen, carbon dioxide, methane, ethane, propane, propylene, isobutane, n-butane, isobutene, n-butene, and isobutene in liquefied gas
The content of various components such as maleic anhydride, dimethyl ether, isopentane, n-pentane, etc. Content range: 0.01%~100%.Calculate the calorific value, Huabai number, density of gas based on the content of each component
Gasification rate, etc.
5. It can be used in the laboratory, online, or as a portable or vehicle mounted device.
2、 Analysis instrument configuration:
1. Liquefied gas analyzer host: Thermal conductivity detector (TCD), built-in hydrogen generator, computer;
2. Calorific Value Edition Gas Dedicated Workstation Set
3. Automatic sampling system
4. Chromatographic column: 1 set of liquefied gas specific chromatographic column
5. Sampling bag 2L
6. Common tools
3、 Instrument parameters:
1. Sensitivity: S ≥ 4000mv.ml/mg
2. Testing items: nitrogen, carbon dioxide, methane, ethane, propane, isobutane, n-butane, isopentane, n-pentane, low calorific value, high calorific value, density, gasification rate
3. Heating value detection range 0~20000kcal/m3
4. Noise: ≤ 0.01mv
5. Drift: ≤ 0.02mv/H
6. Temperature control range: 0~399 ℃
Temperature control accuracy: better than ± 0.1 ℃
Temperature gradient: ≤ 1%
Heating rate: 0-40 ℃/min
7. Hydrogen flow rate: 0-500ml/min
Hydrogen pressure: 0-0.4Mpa
Hydrogen purity: 99.999%
8. Working mode: dual channel simultaneous operation
9. Sampling method: airbag sampling or online use
10. Injection method: automatic
11. Number of digits: 24 digits
12. Sampling period: 60 times/second
13. Zui small resolution: 0.001mv
14. Integral sensitivity: 0.001mV.S
15. Dynamic range: 10-7
16. Analysis time: 7 minutes
17. Zui High Power: 500W
18. Power supply: AC 220V
19. Instrument size: 380 * 430 * 400
20. Instrument weight: 20KG