1
Product images
IIProduct Features:
◆1-4 types of gases can be combined in any way, supporting over 1000 types of detection
Any combination of 1-4 gases, unlimited technical principles, and unlimited detection range
◆Intelligent sensing technology, automatic recognition extension, one machine for multiple purposes
Intelligent gas sensor, plug and play, automatic recognition; By replacing different intelligent gas sensors, it is possible to achieve the improvement of existing onesDetecting gases other than 4 types, with one machine for multiple uses, saving costs; After the expiration of the service life of gas sensors as consumables, there is no need to disassemble or return them to the factory. Simply replace the smart gas sensor, which is easy to maintain.
◆Friendly human-machine interface, perfectly displaying various monitoring data
High definition LCD color screen, real-time display of gas detection, detection unit, detection concentration value, temperature, humidity, alarm records and other information.The combination of gas safety factor and color warning method is used to remind the corresponding safety factor through visual color management.
◆Sensitive response, precise measurement, high accuracy
IIITechnical parameters:
product type |
Single gas detector, composite gas detector (supporting up to four gases for simultaneous detection according to customer needs) |
Support sensors |
More than thirty types of sensors can be freely combined, and up to four types of sensors can be equipped simultaneously |
Sampling method |
Diffuse (optional internal/external sampling pump) |
Concentration unit |
Ppm mg/m ³ can be switched to display with one click, and the concentration value is automatically converted by the system |
display technique |
Monochrome dot matrix 128 * 128 LCD graphic display |
Backlight |
The backlight time can be manually set to automatically turn on when the alarm is triggered |
Direct reading |
Gas molecular formula concentration unit measurement time battery power alarm status data recording status |
data transmission |
Output RS485 signal |
calibration |
Calibration of two target points, both points can be set with calibration values and support one click full channel automatic zero calibration function |
Alarm method |
Sound and light alarm, high and low alarm points can be set with three optional alarm states: on/off, mute |
Explosion proof grade |
Exia CT4 |
protection grade |
IP65 |
working voltage |
24VDC |
operation temperature |
-20℃-50℃ |
Working humidity |
0-90% RH (non condensing, high humidity requires filtering and drying device) |
4Product model and meaning:
GQ - SY- 2□00
G Representing point type combustible gas detectors for industrial and commercial purposes
Q Representing other gases
SYRepresentative enterprise code
2 Representative product serial number
□ doAt 0 o'clock, it represents the principle of catalytic combustion
doAt 1 o'clock, it represents the infrared principle
doAt 2 o'clock, it represents the principle of laser
doAt 3 o'clock, it represents the principle of electrochemistry
doAt 4 o'clock, it represents the PID principle
doAt 6 o'clock, representing otherscombination
00 Representative Design Number
The explosion-proof type of the product is: explosion-proof type, marked asEx d Ⅱ C T6 Gb.
Product execution standards:GB 3836.1-2010、GB 3836.2-2010、GB14048.1-2012、GB4208-2017,GB/T50493-2019,GB15322-2019。