Jiangsu Guochuang Analytical Instrument Co., Ltd
Home>Products>GCTN-9000 Fully Automatic Luminescent Nitrogen Analyzer
GCTN-9000 Fully Automatic Luminescent Nitrogen Analyzer
Brief description: The GCTN-9000 fully automatic luminescent nitrogen analyzer system uses chemiluminescence method to determine the total nitrogen co
Product details
brand Self operated brand Price range discuss personally
Instrument type Chemiluminescence nitrogen analyzer application area Environmental protection, chemical industry, biotechnology, petroleum, energy

GCTN-9000The system uses chemiluminescence method to determine the total nitrogen content, which improves the ability to resist impurity interference, avoids the complex operation of the titration cell caused by the electric method, and greatly improves the sensitivity of the instrument. The key components of the system are imported, ensuring reliable performance of the entire machine.

characteristic

High degree of automation

be based onWindowsChinese operation interface, direct human-machine dialogue. The collection, processing, storage, and printing of data are controlled by computers.The instrument automatically adjusts gas flow rate, samples, cleans, changes samples, generates standard curves, and goes into sleep mode after the analysis process is completed. It can also be set to wake up at regular intervals, fully realizing unmanned analysis.

The instrument execution standard is

SH/T 0657-1998 Determination of Trace Nitrogen in Liquid Petroleum Hydrocarbons (Oxidative Combustion and Chemiluminescence Method)
GB/T 17674-1999 Determination of nitrogen content in crude oil and its products - Chemiluminescence method

ASTM D4629-2010 Standard Test Method for Trace Organic Compound Nitrogen in Liquid Petroleum Hydrocarbons by Injection/Insertion Oxidized Fuel and Chemiluminescence Method

ASTM D5762-2010 Test Method for Nitrogen in Petroleum and Petroleum Products by Ship Inlet Chemiluminescence Method

ASTM D6069-2001- Standard Test Method for Trace Nitrogen in Aviation Hydrocarbons by Oxidative Combustion and Reduction Pressure Chemiluminescence Detection

system configuration

Standard configuration: Computer+GCTN-9000System+fully automaticinjector16Position or110position



GCTN-9Type 000fully automaticLuminescent nitrogen analyzerTechnical Parameter
Basic parameters:Sample type: Liquid
Measurement method:Chemiluminescence method (N)
Sample injection volume:Liquid samples: 5-20μL
Measurement range:0.0520000mg/L(High concentration can be diluted)
measuretimeAbout 2 minutes

PMT high voltage range:DC400V~900V

Measurement accuracy:

Concentration value(ppm)

Injection volume(μL

RSD()

0.1x≤1.0mg/L

20

10

1x≤10mg/L

10

6

10x≤100mg/L

10

2

100

10

1


Temperature control range:Room temperature~1300
precision±1

Correlation coefficient of standard curve≥0.999
Gas source requirements:High purity argon gas: purity99.9%the above,
High purity oxygen: purity99.9%the above
Power supply:AC220V±22V50Hz±0.5Hz1500 W
External dimensions:host:505(W)×541(D)×960(H)mm
Weight:host:40kg

GCTN-9Type 000fully automaticAdvantages of Luminescence Nitrogen Analyzer

  1. The instrument adoptsVertical injectionmode.

  2. Implement injection needleAutomatic cleaning and sample replacementThe program can be set according to requirements.

  3. select16positionthe aboveFully automatic sampler, accurate positioning, one-time setting, fully automatic detectionIt can automatically set the injection volume. Realize unmanned operation and automatic analysis.

  4. The gas flow rate is precisely controlled by a mass flow meterNo manual adjustment is required.

  5. The gas pressure and temperature are precisely controlled by response sensors.

  6. The computer controls the entire process of analysis, data processing, etc., and displays the working status of the entire process. The standard curve can be automatically completed.

  7. Using imported high-quality heating furnace wire,extendLong service life of cracking furnace. The data processing software has an over temperature protection and automatic cut-off function. When the temperature exceeds the set limitlimitThe instrument automatically cools down and enters a protective state.

  8. *The nitrogen reaction chamber enhances the reaction intensity between nitric oxide and ozone, as well as rapidly discharges exhaust gas and reduces tailing.

  9. The aromatic hydrocarbon barrier filtration system and detection system with selective permeable membrane are impossible to contaminate.

  10. Specially designed quartz cracking tube, no need to disassemble or replace, completely solves the problem of carbon deposition in combustion tubes.

  11. The instrument is equipped with a gas filtration and purification system.

  12. Abnormal gas flow rate and pressure, automatic cooling protection of the instrument.

  13. Gas pipelines are connected using spherical clamps for easy maintenance.

  14. The instrument can set the temperature and sleep/wake functions of the cracking furnace. After analyzing the sample, the instrument automatically enters sleep mode.

    The key components are imported componentsReduced instrument noise and improved detection sensitivity.