Controlled by an ARM-32 bit microprocessor, it is reliable, stable, and highly intelligent |
![]() |
Efficient power generation, MPPT design, and increased power generation in complex application scenarios. |
![]() |
Suitable for various DC inputs, photovoltaic, wind power, batteries, etc. |
![]() |
Intelligent fan cooling, low temperature rise, long lifespan |
![]() |
Fast dynamic response and stable speed |
![]() |
Adopting a 7-inch touch screen display and control, the interface is beautiful and the parameter display is diverse |
![]() |
Isolation of power frequency transformer, pure sine wave output of power frequency inverter power supply |
![]() |
RS485 communication interface, standard MODBUS-RTU protocol, can be converted to CAN, TCP/IP interfaces, remotely viewed and controlled through a mobile app |
input parameters
| parameter name | indicator | Remarks |
MPPT voltage range |
180-1150V |
Optional voltage, can accept non-standard customization |
Full load MPPT voltage range |
DC190V-380V DC380V-690V DC690V-1150V |
|
bus |
Multiple circuit options |
customizable |
input switch |
DC MCB switch |
Choose according to the situation |
output parameters
| parameter name | indicator | Remarks |
Rated grid voltage |
3/N/PE,230/400V,220/380V |
|
Voltage range of power grid |
312-528V |
|
Rated grid frequency/grid frequency range |
50Hz/45-55Hz,60Hz/55-65Hz |
|
Total current waveform distortion rate |
<3% (at rated power) |
|
DC component |
<0.5%In |
|
power factor |
>0.99(Under rated power) |
|
Adjustable range of power factor |
0.8 leading -0.8 lagging |
|
Number of Feed Phases/Number of Output Phases |
3/3; 1/1 |
|
efficiency |
90.5% |
Equipped with isolation transformer |
control parameters
| parameter name | indicator | Remarks |
Main control components |
The main measurement and control chip adopts ARM32-bit processor, and the inverter component adopts IGBT |
|
carrier frequency |
4K;8K; 12K; 16K optional |
|
Control voltage and current acquisition method |
valid value |
|
Control method |
Voltage closed-loop control or current closed-loop control |
|
interface |
RS485, MODBUS-RTU protocol |
Optional CAN, TCP/IP, GPRS |
Display parameters
| parameter name | indicator | Remarks |
Display medium |
7-inch touch screen |
|
Display rated parameters |
Input voltage and current; Output three-phase voltage and frequency; Average output line voltage; Output power factor; Output three-phase current; Electricity consumption; |
|
Display alarm content |
Fuse breakage, high IGBT temperature, high transformer temperature, IGBT failure, overload, input undervoltage, etc |
|
Rated parameter display accuracy |
Level 1.0 |
|
Voltage parameter resolution |
0.1V |
Customizable higher resolution |
Resolution of current parameters |
0.1A |
Customizable higher resolution |
protection parameters
| parameter name | indicator | Remarks |
Protection type |
Input no fuse switch, output no fuse switch, electronic circuit quickly detects overcurrent, overvoltage, overload, high temperature, IGBT alarm, fuse alarm, short circuit and automatic tripping protection and alarm |
|
protection method |
Cut off output |
|
DC reverse protection |
possess |
|
Leakage current protection |
possess |
|
DC switch |
possess |
|
Island protection |
possess |
|
Communication short circuit protection |
possess |
|
power grid monitoring |
possess |
|
surge protection |
DC Level 2/AC Level 2 |
|
physical parameters
| parameter name | indicator | Remarks |
Protection level |
Indoor IP20; Outdoor IP23 or higher rating |
|
Isolation method |
Isolation transformer |
|
Working temperature range |
-30-60 ℃ (derating for temperatures greater than 45 ℃) |
|
noise |
55dB |
|
Standby wear and tear |
≤10W |
|
Working humidity range (without condensation) |
0-100% |
|
cooling method |
Can only force cold air |
|
Maximum working altitude |
4000m (>3000m derating) |
|
display |
LED |
|
Power grid support |
LVRT,HVRT,ZVRT, Anti islanding, active and reactive power regulation (optional), PF control, slow start/shutdown |
Model Naming
|
![]() |
Three phase model specifications
| Model number | Capacity (kVA) |
Output current (A) |
Overall dimensions |
|
GCI-T3003 |
3 |
4.6 |
350×650×670 |
GCI-T3006 |
6 |
9.1 |
|
GCI-T3010 |
10 |
15.2 |
|
|
GCI-T3015 |
15 |
22.8 |
460×700×1170 |
|
GCI-T3020 |
20 |
30.4 |
|
|
GCI-T3030 |
30 |
45.6 |
|
|
GCI-T3045 |
45 |
68.4 |
780×650×1450 |
|
GCI-T3060 |
60 |
91.2 |
|
|
GCI-T3075 |
75 |
114.0 |
950×700×1600 |
|
GCI-T3090 |
90 |
136.7 |
|
|
GCI-T3120 |
120 |
182.3 |
|
|
GCI-T3150 |
150 |
227.9 |
1200×750×1800 |
|
GCI-T3200 |
200 |
303.9 |
|
|
GCI-T3250 |
250 |
379.8 |
1400×800×2000 |
|
GCI-T3300 |
300 |
455.8 |
|
|
GCI-T3350 |
350 |
531.8 |
1500×1050×2200 |
|
GCI-T3400 |
400 |
607.8 |
|
|
GCI-T3500 |
500 |
759.7 |
2400×1200×2200 |
|
GCI-T3600 |
600 |
911.6 |
|
|
GCI-T3800 |
800 |
1215.5 |
1500 × 1050 × 2200 two cabinets |
|
GCI-T31000 |
1000 |
1519.4 |
1500 × 1050 × 2200 three cabinets |
|
GCI-T31200 |
1200 |
1823.3 |
Note:Customizable external dimensions and protection level.
Single phase model specifications
| Model number | Capacity (kVA) |
Output current (A) |
Overall dimensions |
|
GCI-T1-500W |
0.5 |
2.3 |
425×436×173 |
|
GCI-T1001 |
1 |
4.5 |
|
|
GCI-T1002 |
2 |
9.1 |
350×650×670 |
|
GCI-T1003 |
3 |
13.6 |
|
|
GCI-T1005 |
5 |
22.7 |
|
|
GCI-T1010 |
10 |
45.5 |
|
|
GCI-T1015 |
15 |
68.2 |
460×700×1170 |
|
GCI-T1020 |
20 |
90.9 |
|
|
GCI-T1030 |
30 |
136.4 |
|
|
GCI-T1045 |
45 | 204.5 | 780×650×1450 |
|
GCI-T1060 |
60 |
272.7 |
|
|
GCI-T1075 |
75 | 340.9 | 950×700×1600 |
|
GCI-T1090 |
90 |
409.1 |
|
|
GCI-T1120 |
120 | 545.5 | 1200×750×1800 |
|
GCI-T1150 |
150 |
681.8 |
|
|
GCI-T1200 |
200 | 909.1 | 1400×800×2000 |
|
GCI-T1300 |
300 |
1363.6 |
Note:Customizable external dimensions and protection level.
Intelligent microgrid, energy storage inverter, photovoltaic, wind power generation, energy recovery, communication, power inverter power supply