GC-920 gas chromatograph
GC-920 gas chromatograph
Product details
GC-920 gas chromatograph with superior performance and complete functions

GC-920 gas chromatograph is a high-performance gas chromatograph designed and produced by Shanghai Haixin Chromatography Instrument Co., Ltd. to meet the requirements of chromatographic users. This machine has the characteristics of modern advanced analytical instruments. Not only does it have a novel appearance, but it also has a unique design, compact structure, and excellent performance that achieves high separation and sensitivity. Suitable for various analytical fields such as petrochemicals, fine chemicals, environmental protection, pesticides, medicine and health, food flavors, etc.


Main Technical Performance

  • Advanced microcomputer control system

    ◎ Adopting microcomputer automatic control. Full keyboard operation;
    A highly stable circuit control system ensures that the instrument has a high degree of reliability;
    ◎ Equipped with comprehensive column box and detector overheat protection function;
    ◎ File storage function for ten analysis condition parameters; Stopwatch function
    ◎ Five stage program heating function;

  • High performance column box

    The temperature control range of the column box is wide. High temperature control accuracy ensures high reproducibility of analysis;
    The large volume structure ensures convenient installation of various specifications of packed columns and capillary columns for users;
    The automatic rear opening of the column box can accelerate the cooling of the furnace temperature and automatically adjust the amount of cold air intake, which is more suitable for capillary chromatography analysis.

  • Multiple configurations of injection system

    ◎ Various diameters of packed columns can be configured for vaporization injection or column loading, capillary split or non split injection, gas valve injection, etc.:
    The packed column and capillary column can be installed simultaneously, making it easy to change the separation method according to analysis requirements. Diversify the analysis.



  • A wide variety of detectors

    All detectors adopt a modular design. It has the characteristics of high sensitivity, low noise, and wide linearity.
    ◎ Multiple detectors can be configured, including TCD, FID, ECD, FPD, NPD, etc., and can also be used to detect elm species simultaneously

  • Specification

    • column oven
      ◎ Temperature range: 8 ℃ to 399 ° C at room temperature (increments of 1 ℃)
      Temperature control accuracy: ± 0.1 ℃
      Heating speed: 5 minutes from ambient temperature to 350 '℃
      ◎ Cooling rate: It takes 7 minutes from 350 '℃ to 100 ℃
    • TPD
      ◎ Maximum order: 5
      ◎ Heating rate setting: 0-40.0 ℃/min (increments of 0.1 ℃/min)
      ◎ Total program time: 655min

    • Sample injection system
      ◎ Temperature range: 10 ℃ to 399 ℃ at room temperature (increments of 1 ℃)
      Temperature control accuracy: ± 0.1 ℃
      Select the injection system from the following units:
      1. Fill column standard injection;
      2. Fill the column for rapid vaporization injection;
      3L large caliber capillary column injection:
      4 capillary column with or without split injection
      Gas valve injection.

    • detector
      ◎ Temperature range: 10 ℃ to 399 ℃ at room temperature (increments of 1 ℃)
      ◎ TCD furnace temperature control accuracy: ± 0.01 ℃
      ◎ Other furnace temperature control accuracy: ± 0.1 ℃

    • Size, weight, power supply
      ◎ Size: Width 650mm x Height 440mm x Depth 480mm
      ◎ Weight:~ 55kg
      ◎ Power supply: 220V 50HZ 2100W

    1. Flame ionization detector (FID)
    Detection limit: 1 × 10-11g/s (n-hexadecane)
    Noise: ≤ 5×10-13A
    Drift: ≤ 5×10-12A/30min


    2. Thermal conductivity detector (TCD)
    Sensitivity: ≥ 2500my · ml/mg (n-hexadecane)
    Structure: Semi diffusive, four arm rhenium tungsten wire
    Noise: ≤ 0.03my
    Drift: ≤ 0.1 mv/30min


    3. Electron Capture Detector (ECD)
    Method: Constant current method using 63Ni radioactive source
    Detection limit: ≤ 5 × 10-13g/ml (Hexachlorocyclohexane)


    4. Flame photometric detector (FPD)
    Method: S or P filter
    Detection limit: 5 × 10-11g (S)/s (sulfur in thiophene)
    1.4 × 10-12g (P)/s (phosphorus in parathion)


    5. Nitrogen phosphorus detector (NPD)
    Alkali source: Rubidium silicate
    Detection limit: 5 × 10-12g/s (N) (azobenzene)
    5 × 10-12g/s (P) (Malathion)