G91, G92 Handheld Unidimensional Gauss Meter
Description: • G91: Accuracy of 2%, range up to 30kG; • G91: Frequency response range DC -10kHz; • G92: accuracy of 1%, range up to 100kG; • G92: freq
Product details


Provide professional magnetic field measurement solutions

Strong magnetic field measuring instrument(0 - 20T)

model

principle

type

number of axles

DCaccuracy

maximum range

Highest resolution

X113

hall

hall sensor

1

<>

15T

TC: 30ppm/K

G80

hall

handheld

1

2%

2T

10μT

G81

hall

handheld

1

0.8%

10T

1μT

G82

hall

handheld-high frequency

1

0.8%

10T

1μT

G83

hall

handheld

3

0.8%

10T

1μT

G92

hall

handheld

1

1%

10T

10μT

G93

hall

handheld

3

1%, 0.5%

20T

1μT

G201

hall

Desktop computer

1

0.2%

10T

1μT

G203

hall/reluctance

Desktop computer

3

0.2%

10T

10nT

G401

hall

Desktop computer

1

0.04%

10T

1μT

G403

hall

Desktop computer

3

0.04%

10T

1μT

GSP301A

hall

Analog transmitter

1

1%, 0.2%

10T

Output: ±3V

GSP301D

hall

Digital transmitter

1

1%, 0.2%

10T

1μT

GSP303D

hall

Digital transmitter

3

1%, 0.2%

20T

1μT

GSP303D-S

hall

Digital transmitter

3

0.5%, 0.1%

3T

1μT

Magnetic field testing system

GAS3000

Array magnetic field detection system, synchronous detection up to128The magnetic field at a certain location

GMS980

High precision Gaussian meter calibration system (High precision Tesla meter calibration device)

Weak magnetic field measuring instrument(0- 2mT)

Weak magnetic field Gaussian meter

model

principle

type

number of axles

DCaccuracy

maximum range

Highest resolution

GMR61

reluctance

handheld

1

0.8%

600μT

10nT

GMR63

reluctance

handheld

3

0.8%

600μT

10nT

GF601

fluxgate

handheld

1

0.5%

1mT

0.1nT

GF603

fluxgate

handheld

3

0.25%

1mT

0.1nT

GF633

fluxgate

Desktop computer

3

0.1%

100μT

0.01nT

GFP703

fluxgate

Smart Transmitters

3

0.5%

1mT

0.1nT

GFP703S

fluxgate

Spectrum analyzer

3

0.5%

1mT

0.01nT

GFP803

fluxgate

Smart Transmitters

3

0.2%

1mT

0.1nT

Communication magnetic field measurement(DC- 1MHz)

model

principle

type

number of axles

ACaccuracy

maximum range

frequency response

AMS-2K

alternating current coil

Analog sensor

1

1%

3mT

30Hz- 2kHz

AMS-1M

alternating current coil

Analog sensor

1

1%

3mT

2kHz- 1MHz

G1000

reluctance

Smart Transmitters

3

DC- 1% AC- 2%

400μT/ Axis

DC- 1MHz

GA1000

reluctance

handheld

3

2%

400μT/ Axis

30Hz- 1MHz

GSP301HFA

reluctance

Analog transmitter

1

1%

150μT

20Hz-1.2MHz

GSP303HFA

reluctance

Analog transmitter

1

1%

150μT

20Hz-1.2MHz

fluxgate sensor

model

principle

type

number of axles

noise level

maximum range

output

F901

fluxgate

Economic type

3

10 to 20pT

1000μT

±10V,single-ended

F902

fluxgate

low noise

3

<>

100μT

±10V,single-ended

F903

fluxgate

low-power consumption

3

10 to 20pT

200μT

±3V,finite difference

F904

fluxgate

low-power consumption|low noise

3

<>

100μT

±3V,finite difference

F905

fluxgate

high-performance|low noise

3

<>

100μT

±10V,single-ended

F23

fluxgate

split type|large range

3

<>

1500μT

±10V,single-ended

F53

fluxgate

High temperature type

3

≤ 300pT@175

100μT

±5V,finite difference

Magnetic flux gate sensor data acquisition unit

FDU301

Connectable1A three-axis flux gate sensor

ASA1000

Connectable2-126A single axis flux gate sensor or2-42A three-axis flux gate sensor

AFS

Array flux gate sensor detection system, capable of connecting multiple flux gate magnetic field transmitters

GMR-16

Micro weak magnetic field sensor array, capable of synchronous acquisition2-16Data from a miniature weak magnetic field sensor

GR100

Digital three-axis flux gate gradiometer

remarks:

1Magnetic field unit conversion:1T= 10kG; 1mT= 10G; 1μT= 10mG; 1nT= 10μG

2Click on the left side of the table abovemodelYou can refer to the product information of the corresponding model


Tag: Magnet Toy Magnetic Measuring Instrument High Frequency Magnetic Field Measuring Instrument Wide Range Gauss Meter Pulse Magnetic Field Measuring Instrument

G91, G92Handheld single dimensional Gaussian meter


sketch:

G91 and G92 Gaussmeters are high-performance handheld single dimensional Gaussmeters launched by Koehler Technologies GmbH in Germany, which can be used for scientific research, laboratories, industry, manufacturing and other users. The 3.2-inch color industrial touch screen provides rich display content, with functions such as maximum/minimum/hold value/magnetic pole/alarm threshold, real-time magnetic field strength, time-domain graph, etc. The G92 Gaussian meter has the widest frequency response range in the world, DC -100kHz.

The DC basic accuracy of Gaussian meter G91 is 2%, with a resolution of 0.2G (20 μ T), a range of up to 30kG (3T), and a frequency response range of DC-10kHz. Radial probe, axial probe, and ultra-thin probe (0.5mm) can be selected.

The DC basic accuracy of Gaussian meter G92 is 1%, with a resolution of 0.1G (10 μ T), a range of up to 100kG (10T), a frequency response range of DC-100kHz, and very low zero drift. The G92P Gaussian meter has a sampling frequency of up to 2000kSPS, allowing it to capture positive and negative pulse magnetic fields with a width of only 200 μ s. This is an ideal choice for most magnetizers and other fast pulse applications.

Users can choose from various types of probes: radial probes, axial probes, miniature axial probes (diameter ≤ 2mm), wide range probes (10T), high-frequency probes (100kHz), high temperature resistant probes (≤ 160 ℃), ultra-thin probes (0.5mm), and probes with built-in temperature sensors. The conventional probe of Gaussian meter G92 does not include a temperature sensor,Its typical temperature coefficient is ± 500ppm/℃The probe with built-in temperature sensor has temperature compensation function, which can improve the accuracy and stability of measurement data when the temperature changes. Therefore, it is strongly recommended to purchase a probe with built-in temperature sensor.

Gauss meters G91 and G92 have passed CE certification and EMC (electromagnetic compatibility) testing.





characteristic

Ergonomic design

Graphical interface operating system

3.2inchLCDcolorful touch screen

Maximum value/minimum value/hold function

Time domain graph display and alarm function

SperhapsNMagnetic pole display

Intelligent recording and viewing

Rechargeable batteries can work continuously for more than24hour

G91: Accuracy2%, with a range of up to30kG

G91frequency responseDC- 10kHz

G92: Accuracy1%, with a range of up to100kG

G92Frequency responseDC- 100kHz

G92High temperature resistant probe(≤160℃)

G92Optional probe with built-in temperature sensor

G92Miniature axial probe(diameter≤2mm)

G92P200μsPeak Sampling Mode





Application industry
Military industry, universities and research institutions, laboratories, industry, manufacturing, food processing industry, toy industry, etc.



Application Cases
1. Magnetic toy magnetic field detection (meets the magnetic field detection standards of toys in various countries and has been widely used in toy testing laboratories of major metrology institutes and entry-exit inspection and quarantine bureaus, such as Fujian Quality Inspection Institute, Shenzhen Metrology Institute, Dongguan Metrology Institute, Ninghai entry-exit inspection and quarantine bureau, etc.);
2. Monitoring of magnetic materials in food production lines, such as magnetic field detection of magnetic shelves at the material inlet of Arrow candy production lines and magnetic field detection of spare parts in Heshuo computer production lines;
3. [G92] High frequency magnetic field detection, such as circuit board induction welding environment magnetic field detection, etc;
4. [G92] Ultra strong magnetic field detection, such as magnetic field detection of superconducting magnets;
5. Narrow space (gap) magnetic field detection;
6. [G92] Pulse magnetic field detection, high temperature environment magnetic field detection;
7. Surface magnetic field detection of permanent magnet materials;
8. Detection of working magnetic fields for DC motors, speakers, magnetic separators, and permanent magnet separators.






Graphical interface operating system


Germany's Koley has developed the first industrial handheld watch operating system (graphical interface operating system), which allows users to operate by touch
G91andG92Gauss meter, efficient and convenient.




display style


color
LCDThe display screen displays various data such as time, real-time magnetic field strength, polarity of magnetic poles, maximum and minimum values, annotations, alarm thresholds, time-domain graphs, etc.







Intelligent recording and viewing

A detailed record list is provided, allowing users to view the details of each measurement data.

By clicking on any record list, users can see the complete stored information, which is displayed in a format similar to a screenshot and can be accompanied by notes for each record.



Magnetic field polarity indication


G91
andG92Gauss meter, in the form of colored dynamic cartoon images, clearly indicates the polarity of the magnetic field. This screen is fromPolarity indication modeAnd displayed in colorLCDOn the screen.







3D Mobile Platform


The 3D mobile platform is made of non-magnetic materials. The user fixes the probe at the front end of the bracket and manually rotates the knob to make the probe move along
X,Y,ZMove steadily in the axial direction to a certain position and lock it in place. The maximum stroke of each axis is150mmThe positioning accuracy is0.1mm.



Zero cavity calibration


exist
500GIn the following magnetic fields, the zero calibration cavity provides up to80Decibel attenuation, used for zero calibration of standard probes. Internal dimensions of the cavity: diameter6.8mm x 44.5mm.








SMARTsoftware


SMART
Computer software has rich functions: it can automatically record and display trend charts and curves; Real time display of magnetic field strength, maximum and minimum values; Can export data saved by the Gaussian meter host; Real time recording and storage of magnetic field strength data, etc.




Probe metal sleeve


The entire series of probes of the Koleos meter are protected by metal sleeves, which can be tightened and fixed with the probe handle to protect the probe from damage caused by impact, compression, etc. It is strongly recommended that users tighten and secure the metal sleeve after completing the magnetic field measurement.





Gauss meterG92Unique features of


200µsPeak Sampling Mode


G92P
The Gaussian meter has the function of capturing extremely short pulse magnetic fields and rapidly changing magnetic field intensity peaks, and can capture up to200μsThe peak value of magnetic field pulses.(This function is an optional feature)


Temperature compensation function


Conventional probes do not include temperature sensors, and their typical temperature coefficient is±
500ppm/℃The probe with built-in temperature sensor has temperature compensation function, which can improve the accuracy and stability of measurement data when the temperature changes. Therefore, it is strongly recommended to purchase a probe with built-in temperature sensor.


High temperature resistant probe


Thanks to the most advanced sensor technology and excellent design, the high-temperature resistant probes manufactured by Koley Company have a rare operating temperature range:
-20℃arrive+160℃ (-4℉arrive+320 ℉).



High frequency probe


Using special anti electromagnetic interference alloy materials and excellent process design, the high-frequency probe of Koley Company is specifically used to measure AC magnetic fields in strong electromagnetic radiation environments, with strong anti-interference ability and frequency response range
DC- 100kHzThe shape and length of the high-frequency probe can be customized.





G91andG92Gaussian meter parameters

model

G91

G92 / G92P

Measurement parameters

accuracy(DC)

±2% Reading ± 0.2%

FS

±1% Reading ± 0.1%

FS

range

300G, 3kG, 30kG

(30mT,

300mT, 3T)

300G, 3kG, 30kG

(30mT,

300mT, 3T)

or

1kG, 10kG, 100kG

(0.1T,

4

4

1T, 10T)

Highest resolution

0.2G(0.02mT)

0.1G(0.01mT)

Display digits

display resolution

0

999.9G

0.1G(0.01mT)

0.1G(0.01mT)

1000G~9999G1G(0.1mT)1G(0.1mT)

≥10kG

10G(1mT)

10G(1mT)

Frequency response range[f

T]DC- 10kHzDC- 100kHzTypical temperature coefficient

±800ppm/±500ppm/(

Conventional probe

)±100ppm/

(

Probe with built-in temperature sensor

)

Typical zero drift0.1G/0.02G/

Peak sampling function

3.2NOG92PThe Gaussian meter has a fast pulse capture function that can capture up to

200μs

Peak value of magnetic field pulsefront paneldisplay screenInch color resistive touch screen,

320 x 240pixelDisplay unitsGaussian(G)Tesla

(T)

3Gaussian(G)Tesla

(T)

Ampere per meter(A/m)Display update rateorder

/

second

display modeDCACMaximum value, minimum value, alarm, polarity display, time-domain graph, etc

probe

Compatible probes1.5details30

Probe specifications

list

1Probe cable lengthstandardRice; The maximum length that can be customized is

2riceUSBinterfacefunctionCommunication interface: used for connectingPCMonitor and measure with Gaussian meter host;

Charging interface: used for connectingPCOr a portable power bank

(

power bank

)

+15Charge the Gaussian meter host.software/driveUpper computer software, no need to install other driversHost specifications

-10operation temperatureto+35(

accuracy rating

)to+60

(

Reduced accuracy

)storage temperature- 20

to +75Environmental magnetic field<>battery

rechargeable

4500mAH

Lithium Ion Battery

Battery operating time

>24

hour(Standard Test Environment)




sizetwo hundred and thirty-eightmm W × 95 mm H × 42 mm D

weight350g

authentication

CE

Certification

EMC

authentication

only

G92Function of Gaussian meter: Analog output Linearity

(DC)

±2% FS

function

Real time output, output voltage proportional to magnetic field strengthFull range voltage±3 V

Proportional relationship

3 Vcorresponding to






Selected range gear



response frequencyDC - 30 kHz

Simulate output impedance

< 100='' ω=''>

Short circuit protection

)

connect

BNC

Analog output conversion cable

Probe specificationsG91Gaussian meter probe

probe Typerange

resolutionFrequency response rangeProbe size

(mm)

operation temperature

(

)

DC

accuracy

(25

)

Surface material of probe rod

Standard radial probe

T08M150G91

30kG

(3T)

0.2G

(20μT)

DC-10kHz

80*2.2*1

-20 ~ +75

±2%

copper

Standard axial probe

A08M150G9130kG

(3T)

0.2G

(20μT)

DC-500Hz

130*Φ6

-20 ~ +75

±2%

aluminium

0.5mm

Ultra thin probe



T06U150G9130kG

(3T)

0.2G

(20μT)

DC-5kHz

60*2.5*0.5

-20 ~ +75

±2%

Polymer materials

G92 /G92PGaussian meter probe

probe Typerange

resolutionFrequency response rangeProbe rod

size

(mm)

operation temperature

(

)

DC

accuracy

(25

)

Surface material of probe rod

Standard radial probe

T08M150G92

T08M150G92T

30kG

(3T)

0.1G

(10μT)

DC-30kHz

80*2.2*1

-20 ~ +75

±1%

copper

Plastic radial probe

T08P150G92

T08P150G92T

30kG

(3T)

0.1G

(10μT)

DC-30kHz

80*2.5*1.3

-20 ~ +75

±1%

plastics

Wide range radial probe

T08W150G92

T08W150G92T

100kG

(10T)

0.1G

(10μT)

DC-30kHz

80*2.2*1

-20 ~ +75

±1%copperHigh temperature radial probeT40H150G9230kG

(3T)

0.1G

(10μT)

DC-30kHz

400*4.5*1

-20 ~

+160

(-4

- +320

)

±1%

copper

High frequency radial probe

T03HF030G92

30kG

(3T)

0.1G

(10μT)

DC-100kHz

30*2.2*1

-20 ~ +75

±1%

copper

Standard axial probe

A08M150G92

A08M150G92T

30kG

(3T)

0.1G

(10μT)

DC-1kHz

130*Φ6

-20 ~ +75

±1%

aluminium

Wide range axial probe

A08W150G92

A08W150G92T

100kG

(10T)

0.1G

(10μT)

DC-1kHz

130*Φ6

-20 ~ +75

±1%

aluminium

Miniature axial probe

A08M150G92A

A08M150G92B

A08M150G92C

A08M150G92D

30kG(3T)

0.1G

(10μT)

DC-1kHz

80*Φ2

80*Φ1.5

80*Φ1.2

80*Φ0.9

-20 ~ +75

±1%

copper

0.5mm


Ultra thin probe

T06U150G92T06U150G92T30kG(3T)0.1G(10μT)DC-10kHz

60*2.5*0.5-20 ~ +75±1%Polymer materials

Note:1The model contains letters at the end“T”The probe with built-in temperature sensor has temperature compensation function, and its typical temperature coefficient is±100ppm/



2Complete calibration range for each probe:≤±2T(±20kG)


3


The probe is only compatible with the corresponding model of host. For example, we cannot

G92

Insertion of Gaussian meter probe

G91Gaussian meter is used.480Sensor center position (radial probe):6.8Metal probe:D=1mm±0.2mmPlastic probe:

D=1.2mm±0.2mm

OptionstypedescribeZC10School zero cavity: in

500G

In the following magnetic fields, up toDecibel attenuation, used for zero calibration of standard probes. Internal dimensions of the cavity: diametermmx 44.5

mm

CAB30

BNC

Analog output conversion cable(Only used for Gaussian metersG92)SAMRT PC SoftwareComputer software for Gauss meter(Comes with the instrument)STD30



Host bracket

GHOLD100The three-dimensional mobile platform of the probe is made of non-magnetic materials. The user fixes the probe at the front end of the bracket and manually rotates the knob to make the probe move alongX, Y, ZMove steadily in the axial direction to a certain position and lock it in place. The maximum stroke of each axis is150mmThe positioning accuracy is

0.1mmCentral load10kg, self weight3.5kgThe most commonly used kitKit Product NumberG9201

Gaussian meter hostG92+probeT08M150G92Kit Product NumberG9202

Gaussian meter hostG92 +probeT08M150G92 +Zero cavity calibrationZC10Kit Product NumberG9101



Gaussian meter host


G91+

08

probe

150

T08M150G91

Kit Product Number

G9102

Gaussian meter hostG91+

probeT08M150G91 +

Zero cavity calibration

ZC10

Probe selection type description

T

M

G92

T

probe Type

A -

Axial probeT -radial probe

X - 2 AXISY - 3 AXISProbe length

06 - 6 cm08 - 8 cm10 - 10 cm

25 - 25 cm

Probe styleC

CRYOGENICF

FLEXIBLEH

HIGH TEMP.

L – LOW FIELD

M – METAL

P

9PLASTICS

– SMALL RANGE9U

ULTRATHIN9W – WIDE FIELDProbe cable length

150 – 150cm

Gaussian meter typeG

1 – G91 probe





G


2 – G

92 probe
G

3 – G
93 probe

Temperature compensation function(Probe with built-in temperature sensor)

T -

have

BLANK -

not have

Comparison with competitors

contrast

COLIY

MODEL G92

FWBELL

3.2MODEL 5180

accuracy

(DC)

1%1%maximum range

3100kG (10T)30kG (3T)Frequency response rangeDC- 100kHz

DC- 25kHz

displayInch color touch screen

Black and white screenDisplay digits *

4 (

give an example:

5678G)

1/2

(

give an example:

5.68kG)

Typical temperature coefficient

±500ppm/

±870 - ±950ppm/Probe protective cover

metal

Soft plastic

operateTouch Screen

key

Polarity display function

havenot have

High temperature resistant probe

(≤+160

)

have

not have

Wide range probe

(10T)

have

not haveHigh frequency probe(100kHz)

have

not have


Intelligent viewing and storage functionhave







Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!