High temperature furnace temperature tracker, including Chinese version analysis software (switchable to English, German, French, Italian, Japanese, Korean, Vietnamese, etc.), computer networkingData LoggerData collector10Channel or20ChannelThermal BarrierA set of measuring heads for the insulation boxProbes、AntennaTransmitting antenna (option), receiver (option).
Tp3Recorder Recorder TP3-TX Recorder |
|
Data loggerdata loggerTP3 |
||
model |
TP3016 |
TP3026 |
Number of channels |
10 |
20 |
casing |
304stainless steel |
|
Sampling interval |
0.1Seconds~50 minutes,1Seconds~50 minutes (wireless telemetry) |
|
Thermocouple type |
Ktype(Other types can also be provided when needed |
|
Recorder accuracy |
±0.30C |
|
Maximum operating temperature |
700C~1000C(High temperature battery) |
|
temperature range |
-1000C ~13700C |
|
storage |
3,600,000A data point |
3,600,000A data point |
Multiple runs |
The recorder can store up to10Run separately next time |
|
battery |
Hydrogen charging battery (optional alkaline battery box or high-temperature battery) |
|
BATTERY LIFE |
1Minute sampling interval(700C)- 200hour |
1Minute sampling interval(700C)- 150hour |
Recorder communication |
USBOr Bluetooth (5-meter)* |
|
Size (length)XwideXHigh) |
200 mm x 98 mm x 20 mm |
|
weight |
1.15 kg |
1.10 kg |
Telemetry capability |
Wired telemetry - standard (cable or Bluetooth *) RFWireless telemetry is optional (seeTP3 RFData Sheet) |
hot boxTS01 20Channel temperature recorder (applyHeat treatment of glass, aluminum, and steel
Insulation box code |
Height mm |
Width mm |
lengthmm |
400℃ |
600℃ |
800℃ |
TS01-90 |
90 |
240 |
538 |
0.7hour |
0.5hour |
0.4hour |
TS01-125 |
125 |
240 |
588 |
2.2 hours |
1.4 hours |
1.1 hours |
TS01-150 |
150 |
300 |
588 |
5.0 hours |
3.0 hours |
2.0 hours |
TS01-175 |
175 |
300 |
588 |
7.0hour |
4.5hour |
2.5hour |
TS01-200 |
200 |
310 |
588 |
8.0hour |
5.0hour |
3.5hour |
TS01-250 |
250 |
350 |
605 |
12.2Hour by hour |
8.5 hours |
6.2hour |
TS01-300 |
300 |
400 |
655 |
16.5Hour by hour |
10.5 hours |
8.0hour |
TS02 20Channel temperature recorder(Heat treatment, uniformity of high-temperature furnace)NADCAP / AMS2750 / CQI9High temperature furnace calibration
The maximum temperature can reach1000℃Specific insulation boxes can be equipped according to usage conditions1100℃
Insulation box code |
heightmm |
widthmm |
lengthmm |
400℃ |
600℃ |
800℃ |
950℃ |
TS02-130 |
129 |
250 |
605 |
2.2hour |
1.4hour |
1.1hour |
0.90hour |
TS02-155 |
155 |
315 |
605 |
5.0hour |
3.0hour |
2.0hour |
1.6hour |
TS02-175 |
175 |
315 |
605 |
6.5 hours |
4.0hour |
2.2hour |
1.8hour |
TS02-200 |
200 |
315 |
605 |
9 hours |
5.5 hours |
3.75 hours |
2.5 hours |
TS02-250 |
250 |
355 |
630 |
12.2hour |
8.2hour |
6.2hour |
4.8hour |
TB02-300 |
300 |
405 |
680 |
16.5hour |
10.5 hours |
8.0hour |
7.0hour |
High temperature stainless steel310、Integral hookTemperature mutation expansion sheet structuretwo-sidedSurface outlet, replaceable probe outlet wear strip
TS03 20Channel temperature recorder(Heat treatment, uniformity of high-temperature furnace)NADCAP / AMS2750 / CQI9High temperature furnace calibration
Insulation box code |
heightmm |
widthmm |
lengthmm |
600℃ |
900℃ |
1000℃ |
1100℃ |
1200℃ |
TS03-100* |
100 |
271 |
538 |
0.8 hours |
0.6 hours |
0.49 hours |
0.43 hours |
0.38 hours |
TS02-250 |
250 |
351 |
630 |
7.3 hours |
5.3 hours |
4.1 hours |
3.8 hours |
3.5 hours |
TS02-300 |
300 |
401 |
680 |
9.2hour |
7.5 hours |
5.6 hours |
5.0 hours |
4.5 hours |
TB02-350** |
350 |
445 |
585 |
10.2 hours |
7.8 hours |
6.2 hours |
5.5 hours |
4.8 hours |
* apply to6thoroughfareTemperature recorder
**Octagonal insulation box
Insulated box(TS06)Water/Polymer quenching insulation box aluminum solid fusion and age hardening(T6)
The system passes through a quenching tank filled with water or polymer (usually a tight aging treatment furnace)
Insulation box code |
height |
width |
length |
Weight Kg |
Weight Kg (filled with water) |
500℃ |
550℃ |
Quenched water |
200℃ |
TB4101 |
210 |
450 |
610 |
31 |
43 |
|
10 hours |
|
|
TB4072 |
160 |
400 |
560 |
26 |
38 |
|
5 hours |
|
|
Insulated box(TS08)Controlled atmosphere brazing(CAB)
No lining material design, reduces harmful oxygen leakage inside the insulation microporous material, and ensures brazingquality
Insulation box code |
Height mm |
Width mm |
500℃ |
600℃ |
700℃ |
TS08-085-1 |
85 |
272 |
|
0.58 |
0.5 |
TS08-104-1 |
104 |
272 |
|
0.83 |
0.58 |
TS08-125-1 |
125 |
272 |
1.5 hours |
1.25 hours |
1 hour |
Insulated box(TS07)Slab addition/Heating of steel billetsSteel slab / billet / bloom reheat
Insulation box code |
height |
width |
length |
Weight Kg |
Weight Kg (filled with water) |
1000℃ |
1200℃ |
1300℃ |
TS07-300-1 |
300 |
595 |
707 |
61 |
87 |
13 hours |
9 hours |
7.5 hours |
Insulated box(TS05)Tunnel kilnKiln Tracker
Insulation box code |
height |
width |
length |
Weight Kg |
Weight Kg (filled with water) |
150℃ |
200℃ |
250℃ |
TS05-120-10 |
120 |
220 |
450 |
10 |
13 |
100 hours |
50 hours |
32 hours |