Product Introduction
A vacuum hot water boiler utilizes the low boiling point of water at low pressure to quickly heat the heat medium water filled in the sealed furnace, causing the heat medium water to boil and evaporate high-temperature steam. The steam condenses on the heat exchange tubes to heat the cold water inside, achieving the purpose of supplying hot water.
The vacuum hot water boiler is equipped with industrial burners with excellent technical performance, which adopt advanced technologies such as automatic proportional adjustment of combustion, automatic adjustment of water supply, program start stop, and fully automatic operation. It also has high and low water level alarms and automatic protection functions such as extremely low water level and shutdown. This type of boiler has the characteristics of compact structure, safety and reliability, easy operation, rapid installation, low pollution, low noise, and high efficiency.
Schematic diagram of heat conversion in vacuum boiler:
Oil (natural gas) → Combustion → Heat medium water → Boiling steam condensation heat transfer (vaporization → condensation → vaporization) → Heat exchanger → Heat conduction → Water
Low nitrogen vacuum hot water boilers have the characteristics of compact structure, safety and reliability, easy operation, rapid installation, low pollution, low noise, and high efficiency. They are widely used for hot water and heating in facilities such as enterprises, hotels, hospitals, office buildings, and civil buildings.
Performance advantages
(2) One machine is versatile, and one boiler can be designed with multiple heat exchangers to provide heating, domestic hot water, swimming pool heating, and more.
(3) Safe and reliable, can be placed in basements and rooftops, and is not restricted by relevant national departments. No approval procedures are required.
(4) No scaling or corrosion (stainless steel design for heat exchangers), with a designed service life of over 20 years.
(5) The integrated design of the boiler and heat exchanger saves space and greatly reduces the footprint.
(6) Fully automatic control system, highly automated, no need for dedicated personnel to be on duty.
(7) Imported burner, efficient combustion, extremely low noise and exhaust emissions.
(8) Efficient and energy-saving, with low operating costs, and a thermal efficiency of up to 96%.
Technical Parameter
Project/Model | ZKW0.7-8560-Y(Q) | ZKW1.05-8560-Y(Q) | ZKW1.4-8560-Y(Q) | ZKW1.75-8560-Y(Q) | ZKW2.1-8560-Y(Q) | ZKW2.8-8560-Y(Q) | ZKW3.5-8560-Y(Q) | |
Heat medium water capacity (L) | 410 | 520 | 568 | 700 | 830 | 980 | 1250 | |
Rated heat generation (MW/h) | 0.7 | 1.05 | 1.4 | 1.75 | 2.1 | 2.8 | 3.5 | |
Rated heat generation | 60 | 90 | 120 | 150 | 180 | 240 | 300 | |
Fuel | Light diesel oil (Kg/h) | 64 | 96 | 128 | 160 | 192 | 256 | 320 |
Heavy oil (Kg/h) | 67.3 | 100 | 134 | 168 | 202 | 269 | 363 | |
Natural gas (m ³/h) | 165 | 116 | 155 | 193 | 232 | 310 | 387 | |
City gas (m ³/h) | 77 | 247 | 330 | 412 | 494 | 659 | 824 | |
Liquefied gas (m ³/h) | 29 | 44 | 58 | 73 | 88 | 117 | 146 | |
heat exchanger | Material/Structure | stainless steel; Straight pipe | ||||||
Work pressure (MPa) | 1.0 | |||||||
Dedicated for heating | Maximum heat generation | 36 | 54 | 72 | 90 | 108 | 144 | 180 |
Warm water circulation volume | 36 | 54 | 72 | 90 | 108 | 144 | 180 | |
pressure loss | 2.2 | 3.0 | 2.0 | 2.6 | 2.5 | 3.5 | 3.3 | |
Heating outlet (DN) | 65 | 80 | 80 | 100 | 125 | 125 | 133 | |
Heating area (㎡) | 6000 | 9000 | 12000 | 15000 | 18000 | 24000 | 30000 | |
Hot water dedicated | Maximum heat generation | 24 | 36 | 48 | 60 | 72 | 96 | 120 |
Heating water volume (m ³/h) | 6 | 9 | 12 | 15 | 18 | 24 | 30 | |
Hot water temperature | 50 | |||||||
pressure loss | 2.0 | 0.6 | 1.5 | 1.8 | 1.5 | 1.8 | 2.0 | |
Discharge diameter (DN) | 40 | 65 | 65 | 80 | 100 | 100 | 125 | |
voltage | Voltage (V) | 220/380 | ||||||
Power Consumption | 2.2(2.6) | 3.7(4.1) | 5.0(6.5) | 7.5(9) | 11(2.5) | 15(16.5) | 18.5(20) | |
Power consumption of blower | 2.2 | 3.7 | 5.0 | 7.5 | 11 | 15 | 18.5 | |
Oil pump power consumption | 0.4 | 0.4 | 1.5 | 1.5 | 1.5 | 1.5 | 1.5 | |
size | Chimney diameter (mm) | 350 | 350 | 400 | 450 | 500 | 550 | 600 |
Length (m) | 2700 | 3200 | 3400 | 4050 | 4700 | 4900 | 5500 | |
Width (m) | 1365 | 1365 | 1600 | 1600 | 1600 | 1800 | 2020 | |
Height (m) | 2345 | 2400 | 2500 | 2580 | 2580 | 2630 | 2700 |