Product Details
1、 The LKJ type formaldehyde metal tube float flowmeter has the characteristics of simple structure, reliable operation, wide applicability, accurate measurement, and easy installation. There are two types of metal rotor flow meters with high temperature and high pressure resistance: ordinary and corrosion-resistant. The above two types are divided into on-site indication type and electric remote transmission type, ordinary flow sensor, instrument material (1Cr18Ni9Ti), and anti-corrosion type (1Cr18Ni9Ti) lined with PTEF.
If the medium measured by the metal rotor flowmeter contains ferromagnetic particles, a magnetic filter should be installed at the inlet of the flowmeter. Its material should be the same as the corresponding flowmeter.
2、 Technical parameters of LKJ type formaldehyde metal tube float flowmeter
Measurement range: Water (20 ℃) 1-200000 l/h
Air (20 ℃, 0.1013MPa) 0.03-4000m3/h
Refer to the flow chart, special flow rates can be customized
Range ratio: Standard 10:1 Special 20:1
Accuracy: Standard Type 1.5 Special Type 1.0
Pressure rating: Standard type: DN15-DN50 4.0MPa DN80-DN200 1.6MPa
Special type: DN15-DN50 25MPa DN80-DN200 16MPa
The pressure rating of the jacket is 1.6MPa
Special types should be negotiated with the factory before selection and ordering
Pressure loss: 7kPa-70kPa
Medium temperature: Standard type: -80 ℃ -+200 ℃: PTFE: 0 ℃ -85 ℃
High temperature type: up to 400 ℃
Medium viscosity: DN15: DN25: DN50-DN150: Environmental temperature: Liquid crystal type -30 ℃ -+85 ℃
Pointer type -40 ℃ -+120 ℃
Connection form: Standard type: DIN2501 standard flange
Special type: Any standard flange or thread specified by the user
Cable interface: M20 * 1.5
Power supply: Standard 24VDC two-wire 4-20mA (10.8VDC-36VDC)
Communication type: 85-265VAC 50HZ
Battery type: 3 6V@4AH Nickel-metal hydride battery
Alarm output: upper or lower limit instantaneous flow alarm
Standard type: open collector output (large) 100mA@30VDC Internal impedance of 100 ohms
Special type: Relay output (large contact capacity) 5A@250VAC )
Pulse output: Accumulated pulse output, with small intervals of 50 milliseconds
LCD display: instantaneous flow display value range: 0-50000
Accumulated traffic display value range: 0-
Protection level: IP65
Explosion proof mark: intrinsically safe type ia Ⅱ CT6, explosion-proof type d Ⅱ CT6
3、 Formaldehyde metal tube float flowmeter LKJ type flow parameters
Tongjing (mm) |
flow range |
Pressure loss kPa |
|||
Water L/h* |
Air M3/h* |
water |
air |
||
Conventional type |
corrosion-resistant type |
Conventional type, anti-corrosion type |
|||
15 |
2.5~25 |
--- |
0.07~0.7 |
6.5 |
7.1 |
4.0~40 |
2.5~25 |
0.11~1.1 |
6.5 |
7.2 |
|
6.3~63 |
4.0~40 |
0.18~1.8 |
6.6 |
7.3 |
|
10~100 |
6.3~63 |
0.28~2.8 |
6.6 |
7.5 |
|
16~160 |
10~100 |
0.40~4.0 |
6.8 |
8.0 |
|
25~250 |
16~160 |
0.7~7.0 |
7.2 |
10.8 |
|
40~400 |
25~250 |
1.0~10 |
8.6 |
10.0 |
|
63~630 |
40~400 |
1.6~16.0 |
11.1 |
14.0 |
|
25 |
100~1000 |
63~630 |
3~30 |
7.0 |
7.7 |
160~1600 |
100~1000 |
4.5~45 |
8.0 |
8.8 |
|
250~2500 |
160~1600 |
7~70 |
10.8 |
12.0 |
|
400~4000 |
250~2500 |
11~110 |
15.8 |
19.0 |
|
40 |
500~5000 |
--- |
12~120 |
10.8 |
9.8 |
600~6000 |
---- |
16~160 |
12.6 |
16.5 |
|
50 |
630~6300 |
400~4000 |
18~180 |
8.1 |
8.6 |
1000~10000 |
630~6300 |
25~250 |
11.0 |
10.4 |
|
1600~16000 |
1000~10000 |
40~400 |
17.0 |
15.5 |
|
80 |
2500~25000 |
1600~16000 |
60~600 |
8.1 |
12.9 |
4000~40000 |
2500~25000 |
80~800 |
9.5 |
18.5 |
|
100 |
6300~63000 |
4000~40000 |
100~1000 |
15.0 |
19.2 |
150 |
20000~100000 |
--- |
600~3000 |
19.2 |
20.3 |
4、 Schematic diagram of LKJ type formaldehyde metal tube float flowmeter:


Customized processing: Yes
Type: Variable Area Formula
Measurement range:
Accuracy level: 1.5%
Nominal diameter: DN15-DN3000
Applicable media: liquid, gas
Work pressure: 1.6-64MPa
Working temperature: -80-200