English

Shenzhen Shangyoutai Technology Co., Ltd
Home>Products>Fluorescence method for measuring dissolved oxygen analyzer
Fluorescence method for measuring dissolved oxygen analyzer
The DO-702 fluorescence based dissolved oxygen online analyzer is an online analytical instrument widely used for continuous monitoring of dissolved o
Product details
Fluorescence method for measuring dissolved oxygen analyzerDetailed Introduction

DO-702 Using fluorescence method to measure dissolved oxygen, the emitted blue light is irradiated on the fluorescent layer, and the fluorescent substance is excited to emit red light. The oxygen concentration is inversely proportional to the time it takes for the fluorescent substance to return to the ground state. There is no oxygen consumption during measurement, the data is stable, the performance is reliable, there is no interference, and the installation and calibration are simple. Humanized sensing of dissolved oxygen data measured by sensors.

Fluorescence method for measuring dissolved oxygen analyzer

Function:% saturation concentration
Measurement range: 0.0 to 400.0, 0.00 to 40.00, 0.0 to 200.0 ug/L
Measurement resolution: 0.1 0.01/0.1
Measurement accuracy±0.2±0.02
Temperature compensation methodPt-1000/NTC22K
Temperature measurement range-10.0 to+130.0 ℃
Temperature compensation range-10.0 to+130.0 ℃
temperature resolution0.1℃
Temperature Accuracy±0.2℃
Range of electrode current measurement-2.0 to+400 nA
Accuracy of electrode current measurement±0.005 nA
Polarization voltage-0.675V
Pressure adjustment range500 to 9999 mBar
Salinity compensation range0.00 to 50.00 ppt
Ambient Temperature0 to+70 ℃
storage temperature-20 to+70 ℃
DisplayLarge backlit dot matrix LCD
Dissolved oxygen current output1 Isolation type 4 to 20 mA Output, * large load 500 Ω
Temperature current output2 Isolation type 4 to 20 mA Output, * large load 500 Ω
Accuracy of current output±0.05 mA
RS485 Modbus RTU Standard Agreement
Communication speed 9600/19200/38400
Relay contact capacity 5 A/250VAC、5A/ 30VDC
Cleaning settings ON:1 Up to 1000 seconds OFF:0.1 Up to 1000.0 hours
A multifunctional relayCleaning/cycle alarm/error alarm
Relay delay action0-120 seconds
Data recording500000 transactions
Language selectionEnglish/Traditional Chinese/Simplified Chinese
USB interfaceRecord downloads and software updates (96 series does not have this feature)
protection gradeIP65
power supply90 to 260 VAC, Power consumption<5 watts
Installation methodPanel installation/wall mounted installation/pipeline installation
weight144 series 0.85 Kg , 96 series 0.55 Kg。

Fluorescence method for measuring dissolved oxygen analyzer