![]() Easily view details from a distance. |
|
![]() LaserSharp ® Auto focus makes it easy to align with the target you need - even when other devices are blocking. |
|
![]() 8 lenses to choose from, providing maximum versatility. |
|
Fluke TiX660 infrared thermal imager infrared image library
What is precision displacement imaging technology?
Normally, there are blank areas between pixels in infrared images that have not been captured by detectors, which are non sensitive spaces between sensing elements. However, Fluke's precision displacement imaging technology expands sensing elements by four times by capturing multiple thermal images instantly, covering 100% of the blank areas and increasing image resolution by four times.
What is Eversharp Multi Focus Imaging System?
The Eversharp multi-point focusing imaging system, which is exclusive to Fluke, can capture multiple images from different focal lengths and combine them into a sharp image, ensuring that your heat map is free from defocusing and every temperature data is accurately focused.
Transform excellent images into spectacular ones. Choose the best lens for your application. You can view the details of related products on the right side. For a complete list, please refer to the bottom of the "Model and Accessories" tab
- Through Fluke Connect ™ Connect to a large wireless testing and measurement tool network*(Not available in all regions).
- Maintain a safe distance for inspection and take close-up photos with a 32x digital zoom camera.
- Choose a convenient image transfer protocol for your application: thermal imager data port: image transfer: SD card USB 2.0、 Video output DVI-D (HDMI). GigE Vision and RS232 were launched in 2015. SmartView ® Software: SD card. USB 2.0, GigE Vision, and RS232 were launched in 2015.
- Capture * Clear IR Fusion with an 8 MP Visible Light Camera ® Image.
- There are multiple viewing options available for viewing images on site using the viewfinder outdoors.
- User defined programmable buttons can be personalized for quick access to commonly used functions.
- The only handheld thermal imager that can add high frame rate mode up to 240 Hz frame rate for premium applications (add option).
What is adding high frame rate mode?
Temperature fluctuations and drastic changes may be key components of certain analyses. Expert level thermal imagers (TiX1000, TiX660, and TiX640) offer optional addition of high frame rate mode (provided when purchasing the thermal imager). Usually only cooling type infrared thermal imagers have this function. By utilizing these infrared sequences, users can record and analyze a large number of data frames per second to better understand temperature fluctuations.
The following frame rates are optional additional options on the imaging device:
- Option 1: 384 × 288 (120 fps)
- Option 2: 640 × 120 (240 fps)
- *Within the wireless service area of the supplier.
| image quality | |||
| IFOV (Spatial Resolution) | 0.8 mRad | ||
| Image resolution (pixels) | 640 x 480 (307200 pixels) | ||
| 1280 x 960 (1228800 pixels) (Precision displacement imaging technology) |
|||
| Frame rate (* at high image resolution) | 60 and 9 Hz | ||
| Precision displacement imaging and dynamic precision displacement imaging (resolution enhancement) | Yes, MicroScan technology can achieve four times the number of infrared measurement pixels | ||
| Provide option to add high frame rate mode -9 Hz models do not have the option to add high frame rate mode: (can be added at the time of ordering) | Option 1: 384 × 288 (120 fps) Option 2: 640 × 120 (240 fps) |
||
| Field of View (FOV) with a standard 30mm lens | 30.9° x 23.1° | ||
| Thermal sensitivity (NETD) | At a target temperature of 30 ° C, ≤ 0.03 ° C (30 mK) | ||
| spectral range | 7.5 µm 至 14 µm | ||
| wireless connection | |||
| Compatible with Fluke Connect ® | Yes, there is Fluke Connect available ® WiFi SD card, only available in approved and certified regions | ||
| IR-Fusion ® technology | |||
| AutoBlend ™ pattern | have | ||
| View mode | Picture in picture, continuous splicing, color alarm (above and below user-defined temperature) | ||
| focus system | |||
| LaserSharp ™ autofocus | have | ||
| autofocus | have | ||
| manual focus | Yes, obtaining more compact framing through finger touch | ||
| EverSharp Multi Focus Imaging System | Yes, the multi focus recording function can capture images from different focal lengths, merge multiple images into one, and display each object clearly with the best image quality | ||
| temperature measurement | |||
| range | -40 ° C to+1200 ° C (-40 ° F to 2192 ° F), high temperature option - can be requested at the time of ordering: * High 2000 ° C (3632 ° F) | ||
| precision | ± 1.5 ° C or ± 1.5% | ||
| Correction function | LDC ™ - Distance correction based on laser rangefinder, emissivity (manual or material list) | ||
| Transmittance, ambient temperature, humidity (options) | |||
| Data storage and image capture | |||
| Image/video storage | SDHC storage card | ||
| Image/data transmission interface | Thermal imager data port support: Image transfer: SD card USB 2.0、 Video output DVI-D (HDMI). GigE Vision and RS232 were launched in 2015 | ||
| SmartView ® Software: SD card. USB 2.0, GigE Vision, and RS232 were launched in 2015 | |||
| General technical indicators | |||
| Laser pointer | Yes, laser level: 2 | ||
| Laser rangefinder | Accuracy: ± 1.5 mm Range: 70 meters (230 feet) Wavelength: 635 nm (red) Laser grade: 2 |
||
| display screen | Large 5.6 "color TFT display screen, 1280 × 800 pixel resolution, suitable for operation under sunlight | ||
| Geographic information positioning | Built in GPS for geographic positioning | ||
| Visible light digital camera | *High resolution of 8 million pixels, capable of capturing images and recording videos | ||
| digital zoom | *High 32x digital zoom | ||
| Text notes | have | ||
| Voice annotation | have | ||
| audio | Integrated microphone and speaker for voice annotation | ||
| A/D conversion | 16 bits | ||
| power supply | External: 12 VDC... 24 VDC Battery: Standard lithium-ion camera battery |
||
| A replaceable smart battery equipped with an LED level indicator | two pieces | ||
| Operating Temperature | -25 ° C to+55 ° C (-13 ° F to 131 ° F) | ||
| Storage temperature | -40 ° C to+70 ° C (-40 ° F to 158 ° F) | ||
| humidity | Relative humidity 10% to 95%, no condensation | ||
| impact | Operation: 25G, IEC 68-2-29 | ||
| vibration | Operation: 2G, IEC 68-2-6 | ||
| Protection level | IP54 | ||
| Ergonomic Design | Portable camera w/handle | ||
| viewfinder | Tiltable LCoS color viewfinder display screen with 800 × 600 pixel resolution | ||
| Size (including 30mm standard lens) | 210 mm × 125 mm × 155 mm (8.25 in x 4.9 in x 6.1 in) | ||
| Weight (including standard 30mm lens) | 1.95 kg (4.3 lb) | ||
| Measurement function (selection) | Multiple measurement points and target areas (ROI), hot/cold spot detection, isotherms, profiles, differences | ||
| Automatic function (selection) | Focus, image, level, range NUC、 Camera recognition, image optimization, alarm sequence | ||
| SmartView ® software | have | ||
| Supported languages | Czech, Dutch, English, Finnish, French, German, Hungarian, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese and Turkish | ||
| warranty period | 2 years | ||
| Model Name | description |
| FLK-TiX660 9 Hz |
Fluke TiX660 infrared thermal imager 9 Hz (640x480)
|
| FLK-TiX660 60 Hz |
Fluke TiX660 infrared thermal imager 60 Hz (640x480)
|
| Thermal Imaging Accessories | |
| FLK-X calibration | Inspection and calibration of standard 30mm lenses and cameras (1024 or 640 lenses) - recommended to be performed every two years. Suitable for TiX1000, TiX660, and TiX640 infrared thermal imagers. |
| FLK-X lens calibration | Single lens calibration for 1024 or 640 lenses (wide-angle, standard, and telephoto lenses) of TiX1000, TiX660, and TiX640 infrared thermal imagers. |
| FLK-X high frame rate mode | Calibrate each individual high frame rate mode of the thermal imager. Suitable for TiX1000, TiX660, and TiX640 infrared thermal imagers. |
| FLK-Xlens/Macro1 | Close range 0.2 times |
| FLK-Xlens/Macro2 | Close range 0.5 times |
| FLK-Xlens/Macro3 | Close range 0.5 times |
| FLK-Xlens/Wide | wide-angle lens |
| FLK-Xlens/Stan | Standard 20mm lens |
| FLK-Xlens/Sup-Wide | ultra-wide-angle lens |
| FLK-Xlens/ultra long focus | super telephoto lens |
| FLK-Xlens/telephoto lens | telephoto lens |
| Batteries, chargers, and adapters | |
| FLK-X charger | Sony BC-VM50 charger and power cord suitable for TiX1000, TiX660, and TiX640 infrared thermal imagers. |
| FLK-X power plug | A 15V power plug with 5 additional components suitable for TiX1000, TiX660, and TiX640 infrared thermal imagers. |
| FLK-X battery | Sony NP-QM battery suitable for TiX1000, TiX660, and TiX640 infrared thermal imagers. |
| Cables and hardware | |
| FLK-X HDMI | HDMI cable suitable for TiX1000, TiX660, and TiX640 infrared thermal imagers. |
| FLK-X Ethernet 5-meter connector | Gigabit Ethernet cable suitable for TiX1000, TiX660, and TiX640 infrared thermal imagers, equipped with LEMO connector, 5 meters long. |