Zhengzhou Chengyue Scientific Instrument Co., Ltd
Home>Products>Flue oxygen analyzer
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    13837189935
  • Address
    401, 4th Floor, Building 5, Zhengzhou Yida Technology New City, Jinzhan Street, High tech Zone, Zhengzhou City
Contact Now
Flue oxygen analyzer
Brief introduction: The flue oxygen analyzer adopts a new imported zirconia sensor with minimal drift. The flue oxygen analyzer has a high-precision t
Product details
Details introduction:

Flue oxygen analyzerWidely used in power, metallurgy, heating, building materials, electronics and other sectors to analyze the oxygen content of flue gas in various industrial boilers and kilns. Monitor and analyze the oxygen concentration of combustion gases in large or small boilers, various industrial furnaces, and combustion devices to achieve reasonable low oxygen combustion, reduce fuel consumption and burn loss, stabilize processes, improve product quality, and reduce environmental pollution.

Flue oxygen analyzerMain features:


Single point calibration can meet the measurement accuracy of the entire range;

Friendly human-machine dialogue menu, intuitive and convenient operation;

With a microprocessor as the core, it has the characteristics of good stability, high reliability, and long calibration cycle;

High precision temperature automatic compensation system to eliminate the influence of environmental temperature;

The measurement range can be expanded to 0~240.00%O

(Oxygen enriched combustion), automatic range switching;

Users can freely set 4-20mA

Output the corresponding upper and lower limits of oxygen concentration;

Enable users to obtain higher precision analog outputs;

Unidirectional or bidirectional communication can be achieved with computers through communication interfaces;Advanced calibration function, online calibration of user standard gas.


Flue oxygen analyzer

Technical parameters:

measuring principle

4New zirconia

Display mode

Digital display2

measuring range

0 ~ 10/25.00% O2Expand range

0 ~ 10/25/40.00% O

(Oxygen enriched combustion)

resolution

0.01%

measurement accuracy

≤±1.5%FS

repeatability

≤±1%90response time

T

≤30SAnalog Output5004~ 20mA.DC

(Non isolated output, load resistance less than)Ohm)0~ 5V.DC(Non isolated output, load resistance greater than)

110KOhm)

Programmable dry contact type passive alarm output with large capacity contacts

220VAC/2A

Other interfaces

RS485

Calibration method

Online calibration

power supply

DC18 ~ 36V/2Aoperation temperaturemeter:

-10~ +50
Probe: Low temperature type:0three hundred and fifty

Medium temperature type:

0

seven hundred1

Dimension

Φ50mm ~ Φ90mm3Probe length

convention

Meter (customizable for other lengths)service life

Year (under normal usage conditions)Installation methodProbe insertion typeDN65Standard flange
Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!