Flue gas analyzer
The XZR500 oxygen sensor of the Michell instrument is used to detect and determine the amount of air required for complete combustion
Product details
The XZR500 oxygen sensor of the Michell instrument is used to detect and determine the amount of air required for complete combustion. It uses advanced zirconia technology to measure oxygen content in harsh environments such as boilers, incinerators, and blast furnaces. Combined with the XCU500 analyzer, it can provide fast and accurate readings under the harshest conditions.





highlight

  • Reliable measurement with good repeatability
  • Easy maintenance and convenient verification
  • Durable and sturdy design
  • Quick installation
  • Easy to operate
XZR-500 Series

technical indicators

sensor type XZR500ST+XCU500WM
Measuring principle Zirconia sensor with built-in reference standard and K-type T/C
performance
gas Damp, dirty, and hot are both acceptable
range 0.01-25% oxygen content
precision Better than ± 2% reading accuracy
response time T90< 15s
repetitiveness ± 0.1%
1% per month
linear Better than ± 1%
Sample gas flow rate The minimum flow velocity of combustion gas is 0.5 m/s
Maximum pressure of sample gas Depending on the application configuration
Maximum temperature of sample gas 最高 1300°C
output
output signal A 0/4~20 mA linear output with isolation; The second output is optional
Output load Greater than 1000 Ω
self-diagnosis contain
Output range Free setting within the range of 0.01-25%
call the police 2-channel alarm; User adjustable (10 W)
1-channel fault alarm
display resolution Standard 0.1%; (0.01% optional)
power supply 115 or 220 VAC, 50/60 Hz
power consumption 110 VA
ambient temperature 0°C ~ 55°C
sensor temperature 600~800 ° C, ideally 700 ° C
Operating Humidity 5-90% RH without condensation
mechanical properties
size 300 x 300 x 200 mm (control unit)
290 x 135 x 650 mm (sensing unit)
weight 10 ~ 15kg, Depending on the application configuration
material XZR-501-304 L stainless steel (700 ° C)
XZR-502- Inconel 600 (1000°C)
XZR-503- HR160 (600°C to 1000°C)
XZR-504-C2000 (600°C)
XZR-505- Halar coating (120°C)
XZR-506 Ceramic (1300 ° C)
Probe size Length 400mm, other options available
Installation method Installation of flue wall
Protection level around-the-clock