Shanghai Keyou Automation Technology Co., Ltd
Home>Products>FW2 Variable Area Float Flow Meter
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
  • Address
    1st Floor, Building 2, No. 89 Huguang East Road, Meilian Industrial Park, Minhang District, Shanghai (201108)
Contact Now
FW2 Variable Area Float Flow Meter
Principle: The float of the structural flowmeter operates based on the principle of variable area and floats inside the conical measuring tube
Product details

Principle, structure

The float of the flowmeter operates based on the principle of variable area and floats inside the conical measuring tube

FW2变面积浮子式流量计

main features

● Full panel scale display

application

Gas liquid dual-use type, industrial automation/mechanical equipment/air compression industry/refrigeration and air conditioning.

Technical Parameter

Setting range: See parameter table for details
accuracy: ± 2.5% total range
Voltage resistance: Customized 200bar (optional)
Average pressure loss: 0.3 bar (at 25 L/min)
Medium temperature: Maximum 100 ℃
texture of material: Shell: 316L stainless steel SUS1.4310
Piston: Glass/316L stainless steel SUS1.4310
Spring: 316L stainless steel SUS1.4310
Connector: 316L stainless steel SUS1.4310
buffer: 316L stainless steel SUS1.4310
seal up: Viton rubber

Parameter Table

Model Type Pressure resistance value PN bar Maximum flow rate L/min (oil) Display range L/min (oil) Total amount KG (k1)
FW2-008F…003 100 60 0.6..8 0.62
FW2-008F…008 100 60 0.6..8 0.62
FW2-008F…015 100 60 1…15 0.62
FW2-010F…003 100 60 0.6..8 0.7
FW2-010F…008 100 60 0.6..8 0.7
FW2-010F…015 100 60 1…15 0.7
FW2-015F…003 100 60 0.6..8 0.8
FW2-015F…008 100 60 1…15 0.8
FW2-015F…015 100 60 2..18 0.8
FW2-015F…028 100 60 2…28 0.8
FW2-020F…008 100 60 0.6..8 1.1
FW2-020F…015 100 60 1…15 1.1
FW2-020F…028 100 60 2..18 1.1
FW2-020F…028 100 80 2…28 1.1
FW2-025F…008 100 60 0.6..8 1.2
FW2-025F…015 100 60 1…15 1.2
FW2-025F…028 100 80 2…28 1.2

dimension

尺寸图
Taking DN15 as an example in the above figure

Applicable Medium

适用介质
Calibrate according to the actual medium

install

Calibration of indication range is applicable for vertical upward flow increase

Model Selection Table

FWR- Flow indicator
Applicable pipe diameter
Threaded interface G1/4 nominal diameter DN8
Threaded interface G3/8 nominal diameter DN10
Threaded interface G1/2 nominal diameter DN15
Threaded interface G3/4 nominal diameter DN20
Threaded interface G1 nominal diameter DN25
Threaded interface G1 1/4 nominal diameter DN32
Connection method
Internal thread (female joint)
MATERIAL DESCRIPTION
POM reinforced plastic liquid body
Stainless steel 1.4301 (304) liquid body
Stainless steel 1.4435 (316L) liquid body
Display range range
Display range: 0.1... 3L/min
Display range: 0.5... 8L/min
Setting range: 1... 15L/min
Setting range: 2... 28L/min
The above selection table does not include selection codes. If you need selection codes, please contact us or fill in your information
Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!