Shanghai Keyou Automation Technology Co., Ltd
Home>Products>FR60 series turbine flowmeter (compact)
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
  • Address
    1st Floor, Building 2, No. 89 Huguang East Road, Meilian Industrial Park, Minhang District, Shanghai (201108)
Contact Now
FR60 series turbine flowmeter (compact)
Principle: The structural turbine flowmeter is a velocity flowmeter. As shown in the figure below, a turbine is placed at the center of the pipeline,
Product details

Principle, structure

Turbine flowmeter is a type of velocity flowmeter. As shown in the figure below, a turbine is placed at the center of the pipeline, supported by bearings at both ends. When the fluid passes through the pipeline, it impacts the turbine blades, generating a driving torque on the turbine, causing it to overcome friction torque and fluid resistance torque and rotate. Within a certain flow range, the viscosity of the fluid medium and the rotational angular velocity of the turbine are proportional to the fluid flow velocity. Therefore, the fluid flow velocity can be obtained by the rotational angular velocity of the turbine, and the fluid flow rate through the pipeline can be calculated.

The speed of the turbine is detected by a sensing coil installed outside the casing. When the turbine blades cut the magnetic field lines generated by the permanent magnet inside the casing, it will cause changes in the magnetic flux in the sensing coil. The sensing coil sends the detected magnetic flux periodic change signal to the preamplifier, amplifies and shapes the signal, generates a pulse signal proportional to the flow rate, and sends it to the unit conversion and flow integration circuit to obtain and display the accumulated flow value; At the same time, the pulse signal is also sent to the frequency current conversion circuit, which converts the pulse signal into an analog current quantity and indicates the instantaneous flow rate value.

fr60-

Selection Guide

FR60-F flange type FR60-C sanitary clamp type FR60-T thread type
Flange type turbine flowmeter Sanitary turbine flowmeter Threaded turbine flowmeter
Caliber: DN10 to DN250 Caliber: DN15 to DN50 Caliber: DN4 to DN50
Accuracy: ± 0.5%/± 0.2%/± 1.0% Accuracy: ± 0.5%/± 0.2%/± 1.0% Accuracy: Accuracy: ± 0.5%/± 0.2%/± 1.0%
Power Supply: DDC 12V to 30V ; Power Supply: DDC 12V to 30V ; Power Supply: DC 12V to 30V ;
Output: pulse, current, voltage, NPN optocoupler, LCD display Output: Three pulse, current, voltage, NPN optocoupler, LCD display Output: Three pulse, current, voltage, NPN optocoupler, LCD display
Flange standard: DIN、ASME 、JIS、 Product application standard Connection method: sanitary clamp Connection method: threaded connection
Can be selected from lubricated bearings Can be selected from lubricated bearings Can be selected from lubricated bearings

main features

● Install high reliability long-life bearings

Excellent repeatability, suitable for ingredients

Excellent low flow velocity measurement performance

Extremely fast response, suitable for use in batch control and proportioning control scenarios

Multi blade structure rotor with high precision

● Steam cleaning is allowed

● Compact type suitable for equipment installation

application

Finished oil, light crude oil, gasoline, light oil, jet fuel, light diesel, naphtha, ethylene, etc

Lubricating oil, hydraulic oil, etc

● Water, pure water, distilled water, deionized water, desalinated water, softened water, etc

Alcohol, benzene, toluene, xylene, butadiene, carbon tetrachloride, methylamine, acrylonitrile, etc

Formaldehyde, oxalic acid, caustic soda, carbon disulfide, etc

Milk, coffee, etc

High temperature media such as thermal oil and kerosene

FR60 index parameters

performance parameter
Accuracy: 0.5% of rate and 0.2% of rate
Repeatability: ± 0.1% of the measured value
Response time: Maximum 50 milliseconds relative to input change
Stability: Stability for more than 6 months is ± 0.1% of the measured value
The impact of environmental temperature: Exceeding the working temperature range is ± 0.25% of the measured value
The impact of installation location: It is necessary to ensure that the sensor is fully loaded and that there are sufficient straight pipe sections in front and behind, in order to ensure installation without any impact
Start time: Starting from zero traffic takes 50 milliseconds
Preheating time: It takes 5 minutes from power on to reaching the rated measurement accuracy
Sensor parameters
Size: DN4 to DN250
Temperature range of the tested fluid: -40 to 120℃; (For customized models with temperatures greater than 120 ° C and less than or equal to 180 ° C, please contact the sales engineer by letter)
Sensor body material: Stainless steel 1.4301 (304), stainless steel 1.4435 (316L), Hastelloy C
Material of impeller and accessories: 430F stainless steel, stainless steel 1.4435 (316L), Hastelloy C
Ball bearing material: 316L SST bearings or ceramic bearings
Process connection: PN10 to PN63
Coil impedance: 1600Ω
Terminal box parameters
Environmental temperature range: -20 to 140° F (-29 to 60 ℃ )
Material of junction box: Stainless steel 1.4301 (304), IEC60529 IP66 (standard), customizable stainless steel 1.4435 (316L)
Converter sealing ring: rubber
Power Supply: DC 12V to 30V, 1A quick fuse;
Protection level: IP65&IP67
Electrical interface: PG13.5
Power: max 0.3 w
Output: Pulse output (for total quantity)

FR60 sensor structure

component describe
1A \\ 1B \\ 1C \\ 1D Sensor casing
2 locating ring
3 Locknut
4 Signal line connector
5 Detection probe
6 support
7 Impeller and bearing components

FR60 turbine flowmeter

Hessman connector (DIN43650)

Sketch Map

FR60-3

Schematic diagram of FR60-B aviation socket connector type 4-20mA and pulse output amplifier

FR60-4

FR60: Schematic diagram of pulse output amplifier section

FR60 sensor size and flow range

Size (mm) Measurable flow range (flow velocity affects accuracy) Size (mm) Measurable flow range (flow velocity affects accuracy)
Minimum m ³/h Maximum m ³/h Minimum m ³/h Maximum m ³/h
4 0.005 0.317 50 0.71 49.5
6 0.01 0.712 65 1.2 84
10 0.028 1.978 80 1.81 127
15 0.064 4.5 100 2.83 198
20 0.113 7.9 125 4.42 309
25 0.177 12.4 150 6.36 445
32 0.289 20.3 200 11.3 792
40 0.452 31.7 250 17.67 1236

FR60-F flange type external dimensions

Size (mm) Flange end face size L (mm) Outer diameter of flange D (mm) Height H (mm) Approximately weight (kg)
PN16 PN40 PN16 PN40 PN16 PN40
10 80 90 90 144 144 3.0 3.0
15 75 95 95 146 146 3.0 3.0
20 85 105 105 151 151 4.0 4.0
25 100 115 115 156 156 4.5 4.5
32 120 140 140 169 169 6.0 6.0
40 140 150 150 180 180 7.0 7.0
50 150 165 165 192 192 9.0 9.0
65 175 185 185 210 210 11.0 11.0
80 200 200 200 224 224 13 13
100 220 220 235 244 251 16.0 19.0
125 250 250 270 271 281 23 27
150 300 285 300 300 307 31.0 37.0
200 360 340 375 353 370 43 53
250 420 395 450 406 433 64.0 80.0

FR60-T threaded connection type external dimensions

Size (mm) End face size L (mm) Outer diameter of the body A (mm) thread specification Height H (mm)
4 50 36 M30*1.5 109
6 50 36 M30*1.5 109
10 50 36 M30*1.5 109
15 75 40 G1 113
20 85 44 G1 117
25 100 52 G1-1/4 125
32 120 58 G1-1/2 131
40 140 69 G2 142
50 150 81 G2-1/2 154

FR60-C clamp connection type external dimensions

FR60-C external dimensions clamp connection
Size (mm) End face size L (mm) Clamp outer diameter (mm) Outer diameter of the body D (mm) Height H (mm)
15 75 51 51 124
20 80 51 51 124
25 100 51 51 124
32 120 51 51 124
40 140 64 64 137
50 150 77.5 77.5 151
65 175 91 91 164

FR60 installation requirements

FR60 Pressure Loss Curve

Ordering Tips

When placing an order, please specify the flow direction, type, diameter, and expected measurement range of the medium. We can help you complete precise calibration at the factory.

If it is a viscous medium, please indicate the viscosity, temperature, type of medium, and flow range.

Model Selection Table

FR60- turbine meter
orifice
DN4 DN6 DN10 DN15 DN20 DN25 DN32 DN40 DN50 DN65 DN80 DN100 DN125 DN150 DN200 DN250 (special pipe diameters such as DN300 are agreed upon for delivery)
output signal
pulse
0-5V
4-20mA
4-20mA+pulse+2-channel switch output
4-20mA+pulse+2-channel switch output+instantaneous flow display+cumulative flow display
Process connection type
Threaded sealed connection
Flange connection
Sanitary grade clamp connection
accuracy
Accuracy 0.2% (applicable for pipelines with DN ≥ DN15)
Accuracy 0.5%
Accuracy 1.0%
Connection
Stainless steel 1.4301 (304) junction box IP67
Aviation socket connector IP65
Hesman connector (DIN43650) IP65
Voltage resistance level
EN 1092-1(DIN) PN10 ASME B16.5(ANSI)CLASS150
EN 1092-1(DIN) PN16 ASME B16.5(ANSI)CLASS300
EN 1092-1(DIN) PN25 ASME B16.5(ANSI)CLASS600
EN 1092-1(DIN) PN40 ASME B16.5(ANSI)CLASS900
EN 1092-1(DIN) PN63 ASME B16.5(ANSI)CLASS1500
EN 1092-1(DIN) PN100 ASME B16.5(ANSI)CLASS2500
EN 1092-1(DIN) PN250 JIS 10K
EN 1092-1(DIN) PN400 JIS 20K
Special standards for product application areas
System power supply mode
12~30V DC
BODY MATERIAL
Stainless steel 1.4301 (304)
Stainless steel 1.4435 (316L)
Hastelloy C
Internal impeller and accessory material
430F stainless steel
Stainless steel 1.4435 (316L)
Hastelloy C
(Special alternative) VARIO
Customized with special parameters
The above selection table does not include selection codes. If you need selection codes, please contact us or fill in your information

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!