feature
|
High Performance
High speed computation
|
Large capacity program memory
|
Independent annotation storage
|
Maximum I/O points
Up to 8 expansion units can be connected to one control unit. For this, the maximum number of I/O points can reach 300. In addition, if extension plugins and FP0 adapters are used, a maximum of 382 points can be achieved.
※ 1 Basic instructions 40%, data transfer and operation instructions 60%
※ 2 C14 is 16K steps
Line Up
20 types of control units
|
11 types of expansion units
|
|
Ry output
|
NPN output
|
PNP output
|
|||||
|---|---|---|---|---|---|---|---|
| AC | DC | AC | DC | AC | DC | ||
| control unit | two p.m. |
●
|
●
|
●
|
●
|
●
|
●
|
| 30 o'clock |
●
|
●
|
●
|
●
|
●
|
●
|
|
| 40 points |
●
|
×
|
●
|
×
|
×
|
×
|
|
| 60 points |
●
|
●
|
●
|
●
|
●
|
●
|
|
| Expansion Unit | two p.m. |
● (No power supply unit) |
-
|
-
|
-
|
-
|
|
| four p.m. |
● (No power supply unit) |
● (No power supply unit) |
● (No power supply unit) |
||||
| 30 o'clock |
●
|
●
|
●
|
●
|
●
|
●
|
|
97 combinations (I/O points)
14:00-300:00
16 types of extension plugins * 3
Input/output, pulse I/O, analog I/O, communication (RS485, RS232C, Ethernet), external memory
※ 3 'Limitations on the Use of FP-X Extension Plugin'
Please read carefully.
PLC FP-X C38AT with multiple functions in one
Input/output, pulse I/O, analog I/O, communication (RS485, RS232C, Ethernet), external memory
Built in analog input/output function.
Built in calendar/clock.
Super strong security performance.
Equipped with channel communication ports.
Equipped with a hybrid, low-cost small PLC FP-X C40RT0A with relay and transistor outputs.
High speed counter 6ch
Ultra high scanning speed of 80ns/step
Maximum 196 I/O points when expanding with abundant I/O points
The multi-functional analog input 2ch can achieve rich and colorful analog inputs (potential input, thermal input, voltage input).
Network
Maximum 3 channels
The communication plugin (2-channel type) and programming port have a total of 3 channels. Combined with rich communication functions, it can be used for various purposes
Ethernet
Use communication plugins (Ethernet) to easily collect inspection data, production data, and error messages through LAN.
Modbus-RTU
It can easily communicate with devices corresponding to the globally recognized industry standard Modbus RTU (binary) without any program. Temperature controllers and frequency converters, etc.
PLC link
If a communication plugin (RS485 type) is used, it is convenient to share bit/word data among up to 16 FP-Xs
Computer link
It can easily communicate with devices corresponding to the Panasonic open protocol "MEWTOCOL" without any program. Display, image detection device, temperature controller, power meter, etc
Universal Serial Communication
|
Positioning
Built in 4-axis pulse output function (transistor output type)
|
FP-X expansion unit
|
Input unit/output unit
| Product Name | power supply | Specifications | Order Product Number |
|---|---|---|---|
| FP-X E16X Extended input dedicated unit |
- (Powered by the left unit) |
24V DC input 16 points ※ 1 | AFPX-E16X |
| FP-X E14YR Extended output dedicated unit |
- (Powered by the left unit) |
2A relay output 14 points ※ 1 | AFPX-E14YR |
Input/output unit (relay)Output)
| Product Name | power supply | Specifications | Order Product Number |
|---|---|---|---|
| FP-X E16R Expand I/O unit |
- (Powered by the left unit) |
24V DC input 8 points, 2A relay output 8 points ※ 1 | AFPX-E16R |
| FP-X E30R Expand I/O unit |
100~240V AC | 24V DC input 16 points, 2A relay output 14 points ※ 2 | AFPX-E30R |
| FP-X E30RD Expand I/O unit |
24V DC | 24V DC input 16 points, 2A relay output 14 points ※ 2 | AFPX-E30RD |
Input/output unit (transistor output)
| Product Name | power supply | Specifications | Order Product Number |
|---|---|---|---|
| FP-X E16T Expand I/O unit |
- (Powered by the left unit) |
24V DC input 8 points, 0.5A/5~24V DC transistor output 8 points (NPN) * 1 | AFPX-E16T |
| FP-X E16P Expand I/O unit |
- (Powered by the left unit) |
24V DC input 8 points, 0.5A/24V DC transistor output 8 points (PNP) * 1 | AFPX-E16P |
| FP-X E30TD Expand I/O unit |
24V DC | 24V DC input 16 points, 0.5A/5~24V DC transistor output 14 points (NPN) * 2 | AFPX-E30TD |
| FP-X E30T Expand I/O unit |
100~240V AC | 24V DC input 16 points, 0.5A/5~24V DC transistor output 14 points (NPN) * 2 | AFPX-E30T |
| FP-X E30PD Expand I/O unit |
24V DC | 24V DC input 16 points, 0.5A/24V DC transistor output 14 points (PNP) * 2 | AFPX-E30PD |
| FP-X E30P Expand I/O unit |
100~240V AC | 24V DC input 16 points, 0.5A/24V DC transistor output 14 points (PNP) * 2 | AFPX-E30P |
Expand FP0 adapter
| Product Name | power supply | Specifications | Order Product Number |
|---|---|---|---|
| Expand FP0 adapter |
24VDC | After connecting the adapter, three FP0R expansion units can be connected to FP-X. Comes with an 8cm expansion cable and power cable. | AFPX-EFP0 |
| ※ | All units have 24V DC input as bidirectional input. |
|---|---|
| ※1 | Due to the lack of a built-in power circuit, it is not possible to connect two units. Comes with an 8cm expansion cable. |
| ※2 | Contains E16 and EFP0. It can be expanded up to a maximum of 8 units. Comes with an 8cm expansion cable. |
| ※3 | Maximum expansion of 3 units. Need to expand FP0 adapter. |
Optional parts
Wiring tools
| Product Name | Order Product Number | |
|---|---|---|
|
Terminal block screwdriver relayOutput type terminal block (Phonenix system) is required for wiring. |
AFP0806 |
|
Loose wire crimping tool Transistor output type accessoryconnectorRequired during wiring. |
AXY52000 |
assemble parts
| Product Name | Order Product Number | |
|---|---|---|
|
FPO installation plate narrow strip 30 type The mounting plate used for tightening screws. 30mm wide type. |
AFP0811 (including 10) |
|
FPO installation plate narrow strip type The mounting plate used for tightening screws. Narrow strip type. |
AFP0803 (including 10) |
|
mounting plate The mounting plate used for tightening screws. Flat type. |
AFP0804 (including 10) |
Input/output cable
| Product Name | Order Product Number | ||
|---|---|---|---|
|
Used for transistor output type I/O cable Attached on one sideconnector10 core loose cable AWG22、0.3mm2、 2 pieces (blue/white) 1 piece |
Length 1m 2 pieces, 1 set |
AFP0521 |
| Length 3m 2 pieces, 1 set |
AFP0523 |
||
| ※1 | For models such as FP0-C10RS, C14RS, E8RS, E16RS, etc., one set (two books) of I/O cables are required. |
| ※2 | For FP0-C16T/E16X and E16T/E16YT models, 1 set (2 pieces) of I/O cables are required each. |
| ※3 | For FP0-C32T/E32T/, 2 sets of I/O cables are required (4 in total). |
Flat cable connector kit (10 cores)
|
Flat cable connector kit core | AFP0808 (4-pack) |
Repair parts
| Product Name | Order Product Number | |
|---|---|---|
|
Terminal socket Accessory relayOutput/terminal block type. Repair components. |
AFP0802 (Including 2) |
|
Loose wire crimping socket Belonging to the transistor output type |
AFP0807 (Including 2) |
|
FP0R power cable (1m in length) Attached to FP0R control unit. |
Afpg 805 (1 pack) |
Loose wire crimping connector
| Product Name | Order Product Number | Applicable cable size | wire gauge | |
|---|---|---|---|---|
| Cable diameter | remark | |||
| Loose wire crimping connector | AXW7221FP | AWG#22 | φ1.5~φ1.1 | AWG # 22 12/0.18 |
| AWG#24 | twisted pair | |||
| AXW7231FP | AWG#26 | φ1.3~φ1.1 | twisted pair | |
| AWG#28 | twisted pair | |||
4-point unit relay (power PhotoMOS type)
|
| Contact composition | category | Rated input voltage | 4-point unit relay | |||
|---|---|---|---|---|---|---|
| model | Order Product Number | Quantity per package | ||||
| 1a×4 | DC dedicated (Equipped with AQZ102) |
DC12V | RT3SP1-12V | Is 34001 | 1 inner box 20 outer boxes |
|
| DC24V | RT3SP1-24V | Is 34002 | ||||
| AC/DC dual-use (Equipped with AQZ204) |
DC12V | RT3SP2-12V | Is 35001 | |||
| DC24V | RT3SP2-24V | Is 35002 | ||||
| (Note 1) | Dedicated to PhotoMOS power. PA relay cannot be equipped. |
| (Note 2) | Please consult regarding the composition of the contact points. |
4-point unit relay (PA relay type)
|
| Contact composition | Rated input voltage | 4-point unit relay | |||
|---|---|---|---|---|---|
| model | Order Product Number | Quantity per package | |||
| 1a×4 | DC12V | RT3S-12V | Is 33001 | 1 inner box 20 outer boxes |
|
| DC24V | RT3S-24V | Is 33002 | |||
| (Note 1) | PA relay type. The standard model cannot be equipped with power PhotoMOS. Please make sure to use voltage driven type. |
| (Note 2) | DC5V can also be ordered. Please consult our company. |
| (Note 3) | Please consult regarding the composition of the contact points. |
4-point terminal
|
| category | Rated input voltage | Order Product Number |
|---|---|---|
| PA relay, power PhotoMOS voltage driven type | DC12、24V | Is 30000 |
|
|
Relays that can be equipped with 4-point terminals
| Product Name | Order Product Number |
|---|---|
| PA relay | APA3311、APA3312 |
| Power PhotoMOS (voltage driven type) | AQZ10 * D (DC specific type) |
| AQZ20 * D (AC/DC dual-purpose) |
| (Note 1) | Do not equip this product with relays other than those mentioned above, otherwise it may cause abnormal operation, malfunction, and connection equipment failure of the product. |
RT-2 relay terminal
|
|
DIN rail installation type
1. Used for crimping terminals
| Input/output format | Voltage specifications | model | Order Product Number | Quantity per package |
|---|---|---|---|---|
| Input for | DC12V | RT2S-ID16-12V | Is 231501 | 1 inner box 10 outer boxes |
| DC24V | RT2S-ID16-24V | Is 231502 | ||
| For output purposes | DC12V | RT2S-OD16-12V | Is 232501 | |
| DC24V | RT2S-OD16-24V | Is 232502 |
2. For direct wiring
| Input/output format | Voltage specifications | model | Order Product Number | Quantity per package |
|---|---|---|---|---|
| Input for | DC12V | RT2S-C-ID16-12V | Is 231511 | 1 inner box 10 outer boxes |
| DC24V | RT2S-C-ID16-24V | Is 231512 | ||
| For output purposes | DC12V | RT2S-C-OD16-12V | Is 232511 | |
| DC24V | RT2S-C-OD16-24V | Is 232512 |