Tianjin Nengpu Technology Co., Ltd
Home>Products>FLUORO 9 PLUS Molecular Fluorescence Spectrometer
FLUORO 9 PLUS Molecular Fluorescence Spectrometer
Product Summary: Tianjin Energy Spectrum FLUORO 9 PLUS Molecular Fluorescence Spectrometer has high-speed fluorescence, luminescence, and phosphoresce
Product details
product description




Product Introduction:

Tianjin Energy SpectrumFLUORO9 PLUSMolecular fluorescence spectrometer hashigh speedFluorescence, luminescence, phosphorescencetest(3D scanning)Function,It is a fast and accurate method for sample analysisapproveWidely applicableUsed for analysis and monitoring of environmental objects, hygiene control, and process monitoringFood safety testing and material researchWaiting for industries.

Advantages and Characteristics

Using a super strong pulsed xenon lamp as the light source and a dual monochromator optical design, it can be calibrated with reference and transmission channels to improve measurement accuracy

The key components used in the instrument, such as the long-life ozone removal xenon lamp light source and the photomultiplier tube detector, are allImportOriginal components200nm-900nmwideWithin the spectral rangehaveAdequate light intensity signal and detection sensitivity.

Unique optical system design,super highSignal to Noise RatioMeet various experimental tests;

Has multi-level bandwidth adjustable functionSuitable for various testing scenarios;

Multiple measurement accessories: including film and powder sample measurement accessoriesUltra trace sample pool,Accessories for semiconductor constant temperature sample pool, water bath temperature control colorimetric dish rack, etcOptional;

high speedWavelength scanning speedCan be inEasily achieve 3D fluorescence spectrum scanning of samples within 1 minute.High speed scanning can shorten the analysis time for unknown samples,Ideal instrument for three-dimensional fluorescence analysis and synchronous fluorescence analysis

uniqueThe optical design ensures high sensitivity of the instrument, with high sensitivity and stability for analysis

exceedtraceSample size testing designCan meet0.5mL sampleThe detection

The system complies withFDA、 Authentication standards, with access control, permission allocation, audit trail, electronic signature and other functions, meet GMP/GLP requirements. Optional 3Q service available

widely used

Serial Number

category

Testing items

Main customer groups

1

vitamin/trace element

VB₁VB₂VAVCSeA1Znclass

Food, medicine, quality inspection, universities(Food BiologyFermentation major)

2

Harmful substances in food

Formaldehyde, fluorescent whitening agent, aflatoxin, benzo [a](a)Pyrene, cyanide, etc

Food, quality inspection, universities(College of Food Science and Technology)

3

pesticide residue

Ethoxytrimethoquinoline, etc

Food, quality inspection, universities(Food BiologyFermentation major)

4

ambient water quality

gutter oil(sodium dodecyl benzene sulfonate)Oil

Class, Benzo(a)Pyrene, etc

Environmental protection, quality inspection, universities(Ocean University)

5

Food coloring additives

Rouge, Eosin, Fluorescent Peach, Sodium Fluorescein, Sunset Yellow, Lemon Yellow, Nitrite, etc

Food, quality inspection, universities(Food BiologyFermentation major)

6

biomedical science

groupAmine, calcium ion concentration, amino acids(Alanine, phenylalanine, tyrosine, tryptophan)classNucleic acid research, such asDNA and RNA, protein research, enzyme kinetics, cellular research, including intracellular ion assays;

Biology, medicine, universities(School of Biomedical Sciences)

7

fluorescence

Fluorescent powder, fluorescent plate, quantum dotsmaterialRare earth materials, etcVoIP ForensicsAnalysis objects of spectral characteristics of ink, paper, etc

Materials, medicine, universities(materializationworker)

8

Ecological Geology

Used in ecological geological researchThe "fluorescence labeling" method is used to study hydrogeological processes. Pollution sources of oil products in ports, rivers, and reservoir waters; Research on the biodegradation process of oil products in natural water bodies by external factors; Study on the effect of reservoir biological activity on chlorophyll fluorescence;

Ecological Geological ResearchUniversities, etc.

9

scientific research

Measurement of luminescent spectral characteristics, study of organic and inorganic luminescent substances, luminescent labels, embedded in biological objectsSpectral purity analysis of fluorescent powder and other luminescent powders;

Research institutes, etc





FLUORO 9 Molecular Fluorescence Spectrometer Technical Parameters

parameter

describe

SCAN

Excitation, emission, synchronization

data pattern

Fluorescence, luminescence, phosphorescence (3D scanning)

monochromator

High resolution machine engraved concave diffraction grating

Detecting receiver

Imported original photomultiplier tube

wavelength range

200~900nm

Photometric range

-9999~9999

light source

150W imported long-life high-pressure xenon lamp, high-performance stabilized light source, automatic ozone removal design

Test sample size

0.5Ml or above (using standard 10mm pool)

operation temperature

15~35℃

Working humidity

45~80% (no condensation, below 70% at 35 ℃ or higher temperature)

Standard energy consumption

380W

transmission mode

usb data transfer

system support

WinXP、Win7、Win10

volume

620Wx520Dx300Hmm

weight

41kg