Duzhi Instrument (Shanghai) Co., Ltd
Home>Products>FISCHER PHASCOPE PMP10 DUPLEX Thickness Gauge from Germany
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    15921165535
  • Address
    No. 418 Huajing Road, Shanzhong Science and Technology Park, Waigaoqiao Free Trade Zone, Pudong New Area, Shanghai
Contact Now
FISCHER PHASCOPE PMP10 DUPLEX Thickness Gauge from Germany
PMP10 DUPLEX 采用相位敏感测量技术,适用于测量粗糙底材上的涂镀层厚度或钢上的镀镍层厚度。对于汽车行业,必须测量铝或镀锌钢板上油漆涂层厚度,而 PMP10 DUPLEX 是此类应用的理想解决方案。该设备可通过单次测量精确测定各涂层的厚度,从而节省时间和成本。PMP10 特别适用于电镀或电路
Product details

Product Description


FISCHER PHASCOPE PMP10 DUPLEX Thickness Gauge from Germany-------A handheld instrument used to measure the thickness of double-layer coatings, PMP10 DUPLEX adopts phase sensitive measurement technology and is suitable for measuring the thickness of coating layers on rough substrates or nickel plating layers on steel.For the automotive industry, it is necessary to measure the thickness of paint coatings on aluminum or galvanized steel plates, and PMP10 DUPLEX is an ideal solution for such applications. This device can accurately measure the thickness of each coating through a single measurement, saving time and cost. PMP10 is particularly suitable for the electroplating or circuit board industry and can be used to inspect conductive coatings on various substrates.
PHASCOPE PMP10 DUPLEX, together with the ESG20 probe, is specifically developed for measuring dual phase coatings (paint/zinc on steel or iron) in the automotive industry. The thickness of the paint and zinc layer is recorded in a separate measurement process and displayed separately on the monitor. Due to the automatic recognition of substrate materials, paint layers can also be measured on aluminum without the need for additional probes.



PHASCOPEPMP10 DUPLEX combines three measurement methods

--------Magnetic induction method DIN EN ISO 2178

Used to measure the total thickness of paint and zinc coatings on iron
--------Amplitude sensitive eddy current method DIN EN ISO 2360

Used for measuring individual paint layers on aluminum

--------Phase sensitive eddy current method ISO 21968

Used for measuring zinc coatings on iron without considering coating overlap





PHASCOPEPMP10 DUPLEXtechnical parameter

measuring method Magnetic induction Magnetic induction
and phase-sensitive
Amplitude-sensitive
Measurement mode DUAL DUPLEX DUPLEX or DUAL
application NE / Fe Iso / Zn / Fe Iso / NE
measuring range 0 - 700 µm Iso 0 - 550 µm
Zn 0 - 150 µm
0 - 2000 µm

measurement error

According to FISCHER standard film

0 - 100 µm ≤ 1 µm
100 - 400 µm ≤ 1 %
400 - 700 µm ≤ 2%
Zn 2 - 30 µm ≤ 0.5 µm
Iso 2 - 100 µm ≤ 1 µm
Iso 100 - 500 µm ≤ 1 %
5 - 100 µm ≤ 2 µm
100 - 2000 µm ≤ 2 %
Repetitive accuracy
withFISCHER standard film shall prevail
0 - 100 µm ≤ 0.5 µm
100 - 700 µm ≤ 0.5 %
Iso 2 - 100 µm ≤ 0.5 µm
Iso 100 - 500 µm ≤ 0.5 %
5 - 100 µm ≤ 0.5 µm
100 - 2000 µm ≤ 0.5 %




PHASCOPEPMP10 DUPLEXcharacteristic

Accurate measurement of nickel, zinc, or copper coating thickness on steel using phase sensitive measurement technology

It can even be measured on rough surfaces

Using DUPLEX to simultaneously measure the paint layer and galvanized layer on galvanized steel plates
Easy measurement using Fischer DataCenter softwareSubsequent processing of values
stableHandheld measuring devices for direct on-site testing


PHASCOPEPMP10 DUPLEXanswerUse:

Nickel coating on steel, copper coating on iron or bronze
Non ferromagnetic metal coatings on non-conductive substrates, such as copper coatings on circuit boards
Double layer application, such as paint layer on aluminum or galvanized steel (PMP10 DUPLEX only)
Hot spray aluminum (TSA) coating on steel
Specially suitable for measuring positions of curved surfaces, convex and concave shapes, as well as rough surfaces
Equipped with special probes for interlayer connection holes in circuit boards
Micro scale coatings on non-magnetic metals, iron, or steel
Micro scale multilayer composed of a single-layer coating layersystem



FISCHER Data Center Software

fromPHASCOPEPMP10 DUPLEXFast and convenient transmission of data to computers is essential, and FISCHER DataCenter software is a powerful tool that provides a wide range of graphical display and statistical analysis functions, making it an ideal choice for quality control: statistical process control charts, cumulative frequency charts, and FISCHER's own FDD ® (Factory diagnostic diagram). The built-in report editor allows measurement data to be easily processed, archived, and printed as separate inspection reports.


Standard configuration and order number:

With attachmentsPHASCOPE PMP10 DUPLEX 603-689
PC-DATEX software for transferring data to Excel
FISCHER DataCenter software for data analysis

Probe and accessory ordering number:

ESG20 probe 603-690
V12 BASE Bracket 604-420



Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!