Shanghai Keyou Automation Technology Co., Ltd
Home>Products>FG gear flowmeter
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
  • Address
    1st Floor, Building 2, No. 89 Huguang East Road, Meilian Industrial Park, Minhang District, Shanghai (201108)
Contact Now
FG gear flowmeter
The principle consists of a measuring box and a pair of elliptical gears installed inside the measuring box, forming a sealed lunar cavity with upper
Product details

principle

A sealed lunar cavity (not absolutely sealed due to the rotation of the gears) is formed by a measuring box and a pair of elliptical gears installed inside the measuring box, along with upper and lower cover plates, as the unit for calculating the primary displacement. When the measured liquid enters the flowmeter through the pipeline, the pressure difference generated at the inlet and outlet drives a pair of gears to rotate continuously, continuously delivering the liquid measured by the initial lunar cavity to the outlet. The product of the number of revolutions of the elliptical gear and four times the displacement per time is the total flow rate of the measured liquid.

structure

The elliptical gear flowmeter consists of a flow transmitter and a counting mechanism. Installing a radiator between the transmitter and the counting mechanism constitutes a high-temperature flowmeter. The transmitter consists of a measuring chamber equipped with a pair of elliptical gear rotors and a sealed coupling, while the counting mechanism includes a reduction mechanism, an adjustment mechanism, a counter, and a transmitter.

application

Suitable for asphalt Lubricating oil. vegetable oil. Diesel fuel Oil Residual oil Kerosene engine oil. Gasoline Heavy oil Fuel oil Thermal oil Crude oil Light oil Insulating oil Hydraulic oil. Waiting for various oil products.

FG齿轮流量计

Technical Parameter

Nominal diameter (mm) DN10~DN200
Measured liquid viscosity: 2~3000(mPa.s)
Protection level: IP65 (specially customized IP68)
Repetitive error: ± 0.2% and ± 0.5% of the measured value
Accuracy level: Level 0.2, Level 0.5
Temperature of the tested medium: Room temperature type:- 20~60℃
High temperature type:+ 60℃~200℃
Ultra high temperature type: 220 ℃
Rated working pressure:
(High voltage can be customized)
Cast iron: ≤ 1.6MPa
Stainless steel: ≤ 1.6MPa or 2.5MPa
Cast steel: ≤ 2.5MPa (4MPa, 6.5MPa optional)
Output signal: Pulse signal or 4-20mA current signal
Current output: load resistance 0~10mA:0~1.5kΩ
4~20mA:0~750 Kω
Digital frequency output: The upper limit of output frequency can be set within 1-5000Hz with photoelectric isolation
The collector of the transistor is open circuited for bidirectional output. External power supply
When conducting at ≤ 35V, the maximum collector current is 250mA
Power supply: DC24V or 3.6V battery
Total power consumption: Less than 20W
Environmental temperature: Minus 40 to+60 ℃
Relative humidity: 5%~95%

Caliber and Flow Parameters Table (Table 1)

Pipe diameter (DN) Selection code Flow range (m3/h)
Conventional viscosity range (mPa. s) Higher viscosity range (mPa. s)
0.3~0.6 0.6~2 2~200 200~1000 1000~2000
mm Accuracy 0.5 Accuracy 0.2 Accuracy 0.5 Accuracy 0.2 Accuracy 0.5 Accuracy 0.2 Accuracy 0.5 Accuracy 0.2
10 10 0.2~0.5 0.15~0.5 0.1~0.5 0.1~0.5 0.05~0.5 0.06~0.3 0.03~0.3 0.03~0.2
10 10(min.) 0.08~0.2 0.1~0.25 0.05~0.25 0.08~0.25 0.05~0.25 0.03~0.05 0.02~0.05 /
15 15 0.75~1.5 0.5~1.5 0.3~1.5 0.3~1.5 0.15~1.5 0.2~1.0 0.1~1.0 0.07~0.7
20 20 1.5~3 1~3 0.5~3 0.5~3 0.3~3 0.4~2.1 0.2~2.1 0.15~1.5
25 25 3~6 2~6 1~6 1~6 0.6~6 0.8~4.2 0.4~4.2 0.3~3
40 40 7.5~15 5~15 2.5~15 2.5~15 1.5~15 2.1~10.5 1.0~10.5 0.7~7.5
50 50 8~24 8~24 4.8~24 4.8~24 2.4~24 2.4~16.8 1.6~16.8 1.2~12
40(50) 40B(50B) 6~20 6~20 4~20 4~20 2~20 2.8~14 1.4~14 1.0~10
65 65 20~40 15~40 8~40 8~40 4~40 5.6~28 2.8~28 2~20
80 80 30~60 20~60 12~60 12~60 6~60 8.4~42 4.2~42 3~30
100 100 50~100 34~100 20~100 20~100 10~100 14~70 6~70 5~50
150 150 95~190 64~190 38~190 38~190 19~190 26.6~133 13.3~133 9.5~95
200 200 170~340 114~340 56~340 56~340 34~340 47.6~238 23.8~238 17~170
pipe diameter Selection code Flow range (L/h)
Conventional viscosity range (mPa. s) Higher viscosity range (mPa. s)
0.8~2.5 2.5~20 20~150 150~350
DN Accuracy 0.5 Accuracy 0.3 Accuracy 0.5 Accuracy 0.3 Accuracy 0.5 Accuracy 0.3 Accuracy 0.5 Accuracy 0.3
6 6 30~120 60~120 20~120 40~120 10~110 20~110 6~60 12~60

Structural materials and pressure resistance, etc

model Collectively referred to as material Shell material gear Shaft and bearings Pressure resistance Mpa
FG10- cast iron cast iron Stainless steel 1.4301 (304)&aluminum alloy Stainless steel bearing 1.6MPa
FG20- cast steel cast steel ≤DN50,6.3MPa;
≥DN65,4.0MPa;
≥DN150,2.5MPa
FG30L- Stainless steel 1.4301 (304) Stainless steel 1.4301 (304) ≤DN50,2.5MPa;
≥DN65,1.6MPa
FG30K- Stainless steel 1.4435 (316L) Stainless steel 1.4435 (316L) 1.4435(316L) ≤DN50,2.5MPa;
≥DN65,1.6MPa

Outline parameter table

1. External dimensions of cast steel type

The nominal Tongjing L H A B D D1 N(one) Φ weightkg
15 200 138 180 232 105 75 4 14 12
20 250 164 160 220 125 90 4 18 18
25 300 202 185 252 135 100 4 18 22
40 300 202 208 293 165 125 4 23 27
50 384 262 312 394 175 135 4 23 66
80 450 337 332 452 210 170 8 23 118
100 555 442 310 478 250 200 8 25 210
150 540 510 347 557 300 250 8 26 260
200 650 650 476 720 36 310 12 26 430

2. Stainless steel type external dimensions

The nominal Tongjing L H A B D D1 N(one) Φ weightkg
10 170 100 167 216 90 60 4 14 7
15 200 120 172 228 95 65 4 14 11
20 230 150 225 238 105 75 4 14 17
25 280 195 232 246 115 85 4 14 21
40 260 178 265 349 145 110 4 18 24
50 260 178 265 349 160 125 4 18 24
65 365 260 319 436 180 145 4 18 60
80 420 305 324 459 200 160 8 18 82
100 515 400 373 554 220 180 8 18 127
150 540 515 397 607 280 240 8 23 280
200 650 650 397 646 340 295 12 23 435

PS: The external dimensions of the high-temperature elliptical gear flowmeter made of cast iron and steel are DN15~DN25. The A and B dimensions are based on the data in the above table plus 160mm heat dissipation extension pipe. The A and B dimensions are based on the data in the above table plus 300mm heat dissipation extension pipe. The remaining dimensions are the same as the corresponding dimensions in the above table. When the medium temperature is greater than 100 ° C, this option needs to be considered

A is suitable for DN15~25

B is suitable for DN40~100

Note: Gear products have different factors such as viscosity and pressure resistance, and cannot provide a detailed list of size items. If specific size drawings are required, please provide detailed parameters.

Model Selection Table

FG10- Cast iron universal gear flowmeter
FG20- Cast steel universal gear flowmeter
FG30L- Stainless steel gear flowmeter. 1.4301 (304)
FG30K- Stainless steel gear flowmeter. 1.4435 (316L)
Applicable pipe diameter
10 DN10- DN200 (mm) refer to the selection code table for details
Connection method
F Flange type connection
T External thread connection
Viscosity of the tested liquid
A 0.3~0.6mpa.s
B 0.6~2mpa.s
C 2~200mpa.s
D 200~1000mpa.s
E 1000~2000mpa.s
Temperature of the measured medium
1 Room temperature type -20~60 ℃
2 High temperature type 60-220 ℃
accuracy class
5 Level 0.5
3 0.25 level
2 Level 0.2
Voltage resistance value
1.0 See parameter options such as 1.0=1MPa for details
signal type
P pulse signal
A 4-20mA current signal
F no signal
Alternative: On site display system
/DA Mechanical character wheel accumulation display unit (optional)
/DA2 Mechanical character wheel accumulation display unit+reset function
/DB LCD digital display unit (optional)
/H Insulation jacket function (this option must be selected for easily curable media)
/C Shrinking and expanding function
FG10- 10 F A 1 5 1.0 P /DA ← Selection Example
Required option: Power supply mode DC 24V /DC24V
Lithium battery 3.6V /DC3.6V
Non powered pointer type 0

Ordering Tips

When placing an order, please specify the flow direction, type, diameter, and expected measurement range of the medium. We can help you complete precise calibration at the factory.

If it is a viscous medium, please indicate the viscosity, temperature, type of medium, and pressure rating inside the pipe.

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!