FB0803Industrial diffusion silicon pressure transmitter

Industrial site process pressure detection and control

Ships and Navigation Systems

Aircraft and aviation systems

Air separation equipment and thermal and hydroelectric units

Gas and oil pipelines

Boiler pipeline pressure control

FB0803XCompact diffusion silicon pressure transmitter

Hydraulic and pneumatic control system

Industrial process detection and control

Laboratory pressure calibration

Engine, internal combustion engine

Locomotive braking system

Refrigerator, air conditioner

Thermal power unit

Compressor, gas dispenser

FB0803ZSanitary diffusion silicon pressure transmitter(No pressure inlet, no cavity, flat membrane structure, anti scaling)

food

medicine

hygiene

make wine


Stable output with high sensitivity

The output of a typical strain gauge sensor is only10mvLeft and right, while the full range output of the diffusion silicon sensor is100mvThe influence of factors such as left and right, interference, and noise is relatively small, and the resolution is greatly improved,There is no dead zone near zero pressure.

High precision and good repeatability

The diffusion silicon piezoresistive pressure sensor realizes pressure sensing, pressure transmission, and electrical conversion on the same component, without intermediate conversion links, pressure hysteresis, or mechanical displacement deformation, ensuring minimal repeatability and hysteresis errors, with good linearity, stability, reliability, and long service life.

Good temperature characteristics

Due to the use of advanced technologies such as laser resistance adjustment and computer compensation, as well as clever control of diffusion concentration, full range temperature drift (sensitivity temperature coefficient) self compensation is achieved. Overcoming the defect of high temperature coefficient in semiconductor chips, the zero position and full temperature drift of the transmitter have reached a high level, expanding the operating temperature range.

Suitable for applications in hazardous and explosive fields and locations

The diffusion silicon pressure transmitter has the characteristics of low current, low voltage, and low power consumption, and belongs to the intrinsic safety explosion-proof product. It has obtained the explosion-proof certificate issued by the national safety explosion-proof organization.

High reliability and anti-interference performance

The product is made of stainless steel material and has a special protective structure. The circuit is designed with a series of protection measures such as lightning protection, anti-interference, overvoltage, and overcurrent, which improves the ability to seal and resist corrosion and harsh working environments. It is fully suitable for the needs of general industrial field measurement and control.


TECHNICAL INDEX

using objects

Liquid, gas or vapor

measuring range

Gauge pressure:010kPa60MPa Absolute pressure: 0100kPa10MPa

Negative pressure:-0.1MPa2MPa

transport go out

420mADC

electricity source

1230VDC

load characteristics

420mADCTwo line system loadR≤50(V-12)Ω

temperature range

ambient temperature -20+70;Standard medium temperature -20+80

Shell protection

be better thanIP65

Explosion proof type

Intrinsically safe typeExiaCT6 GaShould be equipped with external safety barriers;Explosion proof typeExdCT6 Gb

performance index

comprehensive accuracy

Accuracy level:±0.1%±0.25%±0.5%

stability

be better than±0.1%FS/year

Temperature influence

exist -20+70Within the range, the change is less than±0.18% /10

vibration effect

The vibration frequency in any direction is20200HzWhen the change is less than±0.02% FS

impact

Any direction100Gimpact11msAfterwards, the change amount is less than±0.02% FS

Load impact

As long as the terminal voltage of the input transmitter is higher than12VThere will be no load impact

position effect

The installation position does not affect the zero point

structure indicator

Structural materials

Shell:Polyurethane baked paint low copper cast aluminum alloy

The contact medium material is related to the type of sensor selected and the sealing method used

“O”Ring sealing structure: Fluororubber

Process connection

Standard provisionM20×1.5External thread

Electrical connection

Can be led out from any outlet as needed, suitable for cable diameters inφ8.5φ10.0Industrial cables are used as leads for sealing purposes.Universal cable connectors can be selected for the lead out jointPG16perhapsM20×1.5Seal the non lead end with an end cap