The bimetallic thermometer with thermocouple/thermal resistance adopts the integration of bimetallic thermometer and thermocouple/thermal resistance, which not only meets the on-site temperature measurement needs, but also meets the long-distance transmission needs. It can directly measure the temperature of liquid, vapor, gas media and solid surfaces within the range of -80-+500 ℃ in various production processes
● Main technical parameters
Scale dial nominal diameter: 100, 150
Thermal response time: ≤ 40s
precisionGrade I 1.5 ℃; Grade II 2.5 ℃
thermal resistorGrade A ± (0.15+0.005ItI) Grade B ± (0.30+0.005)
Protection level: IP55 Level: 1.0, 1.5
● Appearance and dimensions
| Form | D | A | B | E | d |
| RADIAL | 105 | 23 | 73 |
Φ10 Φ12 Φ14 |
|
| 155 | 23 | 73 | |||
| Axial type | 105 | 50 | 110 | 34 | |
| 155 | 50 | 110 | 34 | ||
| Universal type | 105 | 23 | 178 | 120 | |
| 155 | 23 | 178 | 120 | ||
| Axial type electrical contact | 105 | 40 | 135 | ||
| Radial type electrical contact | 105 | 72 | 150 | 42 | |
| Electric contact universal type | 105 | 40 | 175 | 98 |
● Model and specifications
| model | Dividing number | Temperature measurement range ℃ | accuracy class | Protective tube material | insertion length |
| WSSE-401 | E |
-80-+40 -40-+80 0-50 0-100 0-150 0-200 0-300 0-400 0-500 |
1 . 5 |
1Cr18Ni9Ti 304 316 316L Ha Shi C-276 |
150 200 300 400 500 750 1000 |
| WSSE-501 | |||||
| WSSE-411 | |||||
| WSSE-511 | |||||
| WSSE-481 | |||||
| WSSE-581 | |||||
| WSSP-401 | Pt100 | ||||
| WSSP-501 | |||||
| WSSP-411 | |||||
| WSSP-511 | |||||
| WSSP-481 | |||||
| WSSP-581 | |||||
| WSSXE-401 | E | ||||
| WSSXP-401 | Pt100 | ||||
| WSSXE-411 | E | ||||
| WSSXP-411 | Pt100 | ||||
| WSSXE-481 | E | ||||
| WSSXP-481 | Pt100 |
Note:thermocoupleLevel I,thermal resistorGrade A orders according to the agreement;
Order the remaining materials of the protective tube according to the agreement
● Selection Notice
Model A
bthermocouple/thermal resistorgraduation mark
cthermocouple/thermal resistoraccuracy class
dBimetal thermometeraccuracy class
E Temperature measurement range
F installation fixed form
Material of protective tube g
Insert length h
Example A:Thermocouple bimetallic thermometerAxial type, E-typeLevel I temperature measurement range 0-400 ℃. Active thread M27x2, protective tube 316 insertion length 300mm. That is: WSSE-401 0-400 ℃ l=300mm Grade I protective tube 316