Electrostatic oil fume purifier, oil fume purification
The oil fume is sucked into the electrostatic oil fume purifier by the fan, and some of the larger oil droplets and oil particles are trapped on the f
Product details

The oil fume is sucked into the electrostatic oil fume purifier by the fan, and some of the larger oil droplets and oil particles are trapped on the flow plate due to mechanical collision and obstruction. When the airflow enters the high-voltage electrostatic field, under the action of the high-voltage electric field, the oil fume gas ionizes, the oil mist charges, and most of it is degraded and carbonized; A small number of tiny oil particles move towards the positive and negative plates of the electric field under the electric field force and airflow of the adsorption electric field, and are collected on the plates and flow to the oil collection tray under their own gravity. They are discharged through the oil discharge channel, and the remaining micrometer sized oil mist is degraded into carbon dioxide and water by the electric field and finally discharged into clean air; At the same time, under the action of the high-voltage generator, ozone is generated in the air inside the electric field, removing most of the odors in the flue gas.

微信图片_20200819084633

Precautions for using oil fume purifier

1. Anti leakage measures should be taken at the connection points of each air duct. To ensure the infectivity of the equipment.

2. The variable diameter air duct adjacent to the inlet and outlet of the equipment should be as smooth as possible to ensure the transmission efficiency of the equipment. It is necessary to assemble straight pipes with a length more than 4 times the diameter of the pipe, and use smooth pipes to connect them.

3. To ensure the outcome of infection, the individual fan airflow is assumed to be greater than the intended airflow of the equipment. The equipment must operate at the intended air volume, and users can use a frequency converter to control the fan or install a regulating valve device at the fan outlet to achieve this.

4. So soft connections must be used when connecting the air ducts of the equipment's light fan. The device will not function properly if it is subjected to vibration during operation.

5. To reduce the additional resistance of the fan. It is best to keep a straight pipe section of 1-2 meters at the inlet of the fan.

6. When a unified exhaust fan is used for ventilation, multiple devices are used in parallel. It is also necessary to ensure that the proportion of air volume allocated to each device is close to the proportion of air volume it intends to handle.

7. The equipment should operate under negative wind pressure to ensure its infectivity. The fan must be located in front of the equipment.

8. Rainproof and sunshade awnings should be installed for outdoor assembly. Save the impact on the normal operating life of equipment and increase unnecessary maintenance costs.