Conner (Shanghai) Environmental Technology Co., Ltd
Home>Products>Electromagnetic Radiation Analysis and Detection Instrument EM93
Electromagnetic Radiation Analysis and Detection Instrument EM93
The EM93 electromagnetic radiation analysis and detection instrument is commonly used to measure electromagnetic radiation from mobile communication b
Product details

EM93 Electromagnetic Radiation Analysis and Detection InstrumentScope of application
Commonly used for measuring electromagnetic radiation from mobile communication base stations, broadcasting and television, medical equipment, radar, satellite communication equipment, pager stations, heat sealers, drying equipment, and microwave heating equipment.
EM93 can meet the requirements for measuring ultra-high frequency (ultra short wave) and microwave radiation.
EM93 is divided into three types: EM93A, EM93B, and EM93C, and the probes of each model of instrument are not exactly the same:
-EM93A consists of HF-60105 in the 1MHz-9.4GHz frequency range and HL60100 probe in the 680MHz-10GHz frequency range;
-EM93B consists of EM93A and BL30100E probes;
-EM93B consists of EM93A and BL30100E probes.

EM93 Electromagnetic Radiation Analysis and Detection InstrumentTechnical indicators and configuration
1)EM93A

Technical parameters Technical indicators Instrument features
frequency range 1MHz – 9.4GHz Large frequency range
Reference time base accuracy 0.5ppm The highest precision among similar products
Typical background noise DANL –170dBm/Hz The highest sensitivity in the world
RF peak power probe 1MHz-10GHz Non selective frequency broadband measurement (optional)
electric field intensity 1μV - 1000V/m The maximum limit for electric field strength set by the state is
19V/m(GBZ 2.2-2007)
power density 1μW - 100mW/cm2 The maximum limit for power density specified by the state is
0.1mW/cm2(GBZ 2.2-2007)
Maximum input power +20dBm High safe input power
Typical measurement accuracy <1dB High measurement accuracy
Resolution bandwidth RBW 1kHz–50MHz Configure EMC filter
50MHHz RBW, with a scanning width of 6GHz and a scanning time of less than 3 seconds, is beneficial for detecting sudden interference
display mode Real time maximum value, maintain average value, maximum average value Has spatial averaging function
RF interface SMA interface, female, 50 ohms It can also be transferred to the N interface
volume 260x86x23mm Ultra small volume
weight 430 grams Extremely lightweight
Microcomputer software Significant expansion of original machine functions to achieve a multifunctional testing platform Allow users to set their own limit standards
Other characteristic examples True RMS detection, AM/FM/PM demodulation

Note: Microcomputer software can greatly expand the functions of EM81, EM83, and EM93 electromagnetic radiation analyzers, making them not only suitable for on-site measurement of electromagnetic radiation, but also for continuous monitoring of electromagnetic radiation. All microcomputer software is free, and software upgrades are free.


2)EM93B
EM93B consists of EM93A and BL30100E probes. The technical specifications of BL30100E probe are as follows:

Working frequency band gain Antenna factor impedance Size (cm) Weight (grams) Type of connector
30MHz-1GHz -31-1dBi 17-31dB/m 50Ω 54/23/23 1150 N-type, vaginal head


3)EM93C
EM93C consists of EM93A, BL20300 probe, and high gain external preamplifier. The technical specifications of BL20300 probe are as follows:

Working frequency band gain Antenna factor impedance Size (cm) Weight (grams) Type of connector
20MHz-3GHz -45-1dBi 20-51dB/m 50Ω 35/16/14 350 N-type, vaginal head

The technical specifications of high gain and low noise preamplifier are as follows:

Working frequency band 1MHz gain 6GHz gain impedance Size (mm) Weight (grams) Type of connector
1kHz-8GHz 40dB 35dB
High precision linearity
50Ω 82/48/26 300

An SMA Yin Head Input
Another SMA positive head output


EM93Supply List for Each Model
1)EM93A:
-HF-60105 spectrum analyzer: 1 unit;
-Standard HL60100 directional probe: 1;
-Multi functional tripod: 1 piece;
-1300mAh rechargeable battery: 1 unit;
-Charger: 1 unit;
-SMA joint tightening wrench: 1 piece;
-SMA adapter: 1 piece;
-1 meter long SMA cable: 1 piece;
-User manual and microcomputer software CD (with available software for built-in configuration): 1 each;
-USB cable: 1 cable;
-Instrument sheath: 1 piece;
-Aluminum box: 1 piece.
2)EM93B:
-Including all materials in the EM93A supply list mentioned above, in addition to:
-BL30100E probe: 1;
-1 SMA-N adapter;
-Pressure resistant engineering plastic box: 1 piece.
3)EM93C:
-Including all materials in the EM93A supply list mentioned above, in addition to:
-BL20300 probe: 1;
-SMA-N adapter: 1 piece;
-Pressure resistant engineering plastic box: 1 piece;
-High gain external preamplifier: 1 unit;
-USB cable: 1 piece;
-Charger: 1 unit;
-Pre amplifier user manual: 1 unit;
-Aluminum box: 1 piece.

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!