Electrical comprehensive monitoring system
1、 System Overview
Product details

1、 System Overview

In order to prevent electrical equipment and circuit failures from causing fires, eliminate electrical fire hazards, ensure the reliability and safety of fire equipment power supply, protect personal and property safety, and improve the utilization rate of system equipment, the "DGJ08-2048-2016 Civil Building Electrical Fire Protection Design Regulations" stipulate the relevant content of the electrical comprehensive monitoring system.

According to relevant standard requirements, Ankerui Electric Co., Ltd. has actively launched the Acrel-5000EIM electrical comprehensive monitoring system with strong research and development capabilities and more than ten years of rich experience in electrical safety solutions. The system deeply optimizes and integrates power monitoring system, energy consumption monitoring function, electrical fire monitoring, fire equipment power monitoring, surge protection monitoring and other system functions into a unified system, simplifies equipment configuration and on-site wiring, improves equipment utilization, reduces user costs, saves social resources, and reduces user operation and maintenance costs.

2、 System functions

① Real time warning
Real time monitoring of electrical fires, fire equipment power supply, fire doors, emergency lighting and evacuation instructions, surges, and the operation status of power supply and distribution equipment. In case of abnormal voltage of fire equipment power supply, abnormal residual current of circuits, abnormal temperature of cables or busbars, abnormal operation of surge protectors, etc., timely alarms are issued to remind operation and maintenance personnel to handle them, eliminate hidden dangers as soon as possible, and ensure personal and property safety. The system is capable of real-time monitoring of remote signaling changes, protection actions, accident tripping, as well as events such as voltage, current, power, and power factor exceeding limits in distribution circuit breakers, isolating switches, grounding knives, and other devices, and issuing alarms based on the event level. When the system alarms, a real-time alarm window will automatically pop up and sound or voice reminders will be issued.
② Run monitoring
The system monitors in real-time the current, voltage, power, electrical energy, residual current, cable and busbar operating temperature of each circuit outgoing from the substation, the operation status of the main and backup power sources of the fire-fighting equipment, surge protection, the opening/closing status of the fire door, the operation of emergency lighting and evacuation indicator batteries, the operation of lights, linkage signals, the closing and opening status of various distribution circuit breakers, isolation switches, ground knives, etc. It is dynamically displayed in graphics and has a user-friendly human-machine interface.
③ Energy consumption analysis of buildings
The electrical comprehensive management system supports statistical analysis of sub item energy consumption, branch energy consumption, and regional energy consumption, as well as statistical analysis of energy consumption on working days, non working days, etc., and generates analysis reports on a year-on-year and month on month basis.
④ Electrical safety assessment
Based on the current, voltage, residual current, main/backup power status, battery operation status, linkage signal, switch status, and fault tripping model of the power supply circuit, and considering abnormal events such as residual current action, cable overheating, fire equipment power overvoltage, undervoltage, short circuit, fault tripping, and current voltage exceeding limits, a safety analysis of the system or equipment is conducted to provide evaluation conclusions and recommendations for the operation and maintenance of user equipment and cables.
⑤ Viewing System History Events
Store and manage abnormal events such as residual current action, cable overheating, fire equipment power overvoltage, undervoltage, short circuit, fault tripping, current and voltage exceeding limits, etc., to facilitate users' historical traceability of system events and alarms, query statistics, and accident analysis.
⑥ Historical data statistics
The rich reporting system supports meter reading summary and statistics functions such as timed and time-based. Users can freely query the electricity consumption of each distribution node during any time period since the normal operation of the system, and provide statistical analysis reports on the electricity consumption of incoming lines and branch circuits at the station. This function makes electricity consumption visible and transparent, and can be analyzed and traced when there is a large error in electricity consumption, maintaining the correctness of the measurement system.

3、 Subsystem Introduction

1. Power monitoring system

① Introduction

The power monitoring system is suitable for monitoring and controlling the operation status of user end power supply and distribution systems with voltage levels of 35kV~0.4kV in various industries. It provides uninterrupted protection, monitoring, and control for user distribution networks and electrical equipment, improves the reliability of user power supply, enhances the automation level of user power supply and distribution systems, and achieves reliable, safe, and efficient distribution and use of electricity.

② System architecture

③ System functions

④ Selection


2. Energy consumption monitoring system

① Introduction

The building energy consumption monitoring system consists of energy consumption measuring devices, data collectors, and network communication equipment. The system has functions such as data collection, data storage, data processing and analysis, system management, system operation status monitoring, and fault diagnosis. It conducts statistical analysis according to the principles of classification and sub item, generates and displays statistical data and related charts on the energy consumption of each classification, sub item, unit area, and total energy consumption of the building, facilitates the identification of high energy consumption points or unreasonable energy consumption habits, effectively saves energy, and provides accurate data basis for users' further energy-saving renovation or equipment upgrading.

② System architecture

③ System functions

④ Selection


3. Electrical Fire Monitoring System

① Introduction

  The electrical fire monitoring system receives signals from on-site equipment such as residual current electrical fire detectors, monitors, controls, and manages the operation of circuits and equipment. When abnormal situations such as residual current exceeding limits or cable overheating occur in the protected electrical circuits, it issues alarms, promptly notifies operation and maintenance personnel, promptly handles abnormalities or faults, eliminates electrical fire hazards, and protects people's lives and property safety. The Acrel-6000 electrical fire monitoring system is suitable for intelligent buildings, high-rise apartments, hotels, restaurants, commercial buildings, industrial and mining enterprises, national key fire protection units, as well as petrochemical, cultural, educational and health, finance, telecommunications and other fields. It always protects electrical equipment and cables scattered throughout the building and is a loyal guardian of people's life and property safety.

② System architecture


③ System functions

④ Selection


4. Fire equipment power monitoring system

① Introduction

  The AFPM fire equipment power monitoring system can effectively reduce the failure rate of fire equipment power supply, ensure the normal operation of fire equipment, and provide strong technical support for the normal operation of fire equipment, personnel evacuation and rescue in case of fire. The AFPM fire equipment power monitoring system will provide "escort" for fire equipment and play a positive role in effectively safeguarding people's lives and national property security.

② System architecture

③ System functions

④ Selection

5. Fire door monitoring system

① Introduction

  The AFRD fire door monitoring system centrally controls the working status of various terminal devices, including electric door closers and electromagnetic release devices, and monitors the opening, closing, and fault status of evacuation fire doors in real time. It displays real-time fault signals such as open and short circuits of terminal devices, effectively ensuring the stability and safety of the system. It is widely used in airports, rail transit, tunnels, passenger hubs, hospitals, schools, sports halls, exhibition halls, star rated hotels, high-end commercial buildings, and other places.

② System architecture

③ System functions

④ Selection

6. Fire emergency lighting and evacuation indication system

① Introduction

  The fire emergency lighting and evacuation indicator system, through real-time monitoring and dynamic analysis of the safety performance of emergency indicator lights, can quickly analyze and judge the wind direction, nearby exits, fire trend, and crowd density in the event of a fire, calculate the safest evacuation indicator path, turn on the corresponding indication direction of the fire emergency sign lights and emergency lighting, help personnel in the building choose the best escape route correctly, smoothly and quickly evacuate, and maximize the protection of the personal safety of the masses. This system is mainly used in airports, rail transit, tunnels, passenger hubs, hospitals, schools, sports centers, exhibition halls, star rated hotels, high-end commercial buildings and other places.

② System architecture

③ System functions

Fire linkage function
Fault alarm function
Remote monitoring function
Emergency evacuation function
programmability
Self checking function
Record storage and query function
Optical flow function
Permission control function

④ Selection

name

model

content

Installation method

display

Centralized power supply and centralized control fire emergency sign lighting fixtures

A-BLJC-2OEⅡ1W-A420

EXIT

hang

two-sided

A-BLJC-2LEⅡ1W-A420L

Left direction indication

A-BLJC-2LREⅡ1W-A420LR

TWINSPAN

A-BLJC-1OEⅡ1W-A401

EXIT

Wall mounted

Single sided

A-BLJC-1LEⅡ1W-A401L

Left direction indication

A-BLJC-1REⅡ1W-A401R

Right direction indication

A-BLJC-1LREⅡ1W-A401LR

TWINSPAN

A-BLJC-1OEⅡ1W-A401F

Floor indication

A-BLJC-1LEⅠ1W-A500L

180mm unidirectional, glass surface

underground

A-BLJC-1LREⅠ1W-A500LR

180mm bidirectional, glass surface

A-BLJC-1LEⅠ1W-A501L

180mm unidirectional, stainless steel surface

A-BLJC-1LREⅠ1W-A501LR

180mm bidirectional, stainless steel surface

A-BLJC-1LEⅠ1W-A502L